• 제목/요약/키워드: Cross diffusion

검색결과 334건 처리시간 0.027초

$SF_6-Ar$ 혼합기체(混合氣體)의 MCS-BEq알고리즘에 의한 전자(電子) 평균(平均)에너지 해석(解析) (Analysis on the Mean energy of electrons in $SF_6-Ar$ Mixtures Gas used by MCS-BEq Algorithm)

  • 김상남;하성철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2004
  • Mean energy of electrons in $SF_6-Ar$ Mixtures Gas used by MCS-BEq algorithm has been analysed over the E/N range $30{\sim}300[Td]$ by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6-Ar$, 0.1[%] and 5.0[%], $SF_6-Ar$ mixtures were measured by time-of-flight(TOF) method. The transport Coefficients for electrons in (100[%])$SF_6$. (100[%])Ar, (0.2[%])$SF_6-Ar$ and (0.5[%]) $SF_6-Ar$, (5.0[%]) $SF_6-Ar$, (0.1[%])$SF_6-Ar$ mixtures were measured by time-of-flight method, and the electron energy distribution function and the parameters of the velocity and the diffusion were determined by the variation of the collision cross-sections with energy. The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

몬테칼로법을 이용한 Ar기체의 전자수송계수에 관한 연구 (A study on the electron transport coefficients using monte carlo method in argon gas)

  • 하성철;전병훈
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권6호
    • /
    • pp.685-692
    • /
    • 1995
  • The electron transport coefficients in argon gas is studied over the range of E/N values from 85 to 566 Td by the Monte Carlo method considering the latest cross section data. The result of the Monte Carlo method analysis shows that the value of the electron transport coefficients such as the electron drift velocity, the ratio of the longitudinal and transverse diffusion coefficients to the mobility. It is also found that the electron transport coefficients calculated by the two-term approximation analysis agree well with those by Monte Carlo calculation. The electron energy distributions function were analysed in argon at E/N=283, and 566 Td for a case of the equilibrium region in the mean electron energy. A momentum transfer cross section for the argon atom which was consistent with both of the present electron transport coefficients was derived over the range of mean electron energy from 10.3 to 14.5 eV, also suggested as a set of electron cross section for argon atom. The validity of the results obtained has been confirmed by a Monte Carlo simulation method.

  • PDF

크로스토크 제거를 통한 입체 음향 구현에 관한 연구 (A Study on the Implementation of Realistic Sound Through Cross-Talk Cancellation)

  • 김학진
    • 대한전자공학회논문지SP
    • /
    • 제41권2호
    • /
    • pp.99-108
    • /
    • 2004
  • 5.1채널 스피커 시스템을 이용하여 음향을 재현 시 나타나는 현상인 크로스토크를 제거하여 청취자에게 보다 입체적인 음을 재현하는 방법에 관한 것이다. 본 논문에서는 자유음장 모델에 기초하여 5.1채널 스피커 시스템의 보상함수를 해석, 이를 심리음향에 기초한 바크 스케일(bark scale) 등가 보상 밴드패스 필터에 적용하여 주파수 제한적인 음질 보상을 실시하였다. 정면 채널과 서라운드 채널의 음원을 제작하여 기존의 2채널 및 5.1 시스템에서 제시하는 음원과 비교하여 객관적인 음질평가 및 청취자를 대상으로 한 주관 평가를 실시하였다. 제안된 방법에 따라 측정한 결과에 따르면 ±30。의 정면 스피커를 배치한 돌비 표준 스피커 배치에서 38㏈ 이상의 분리도를 얻었으며 확산감에 대해 전문가를 대상으로 한 주관 평가는 5점 평가를 기준으로 0.4점이 향상되었다.

크로스토크 제거를 위한 바크스케일 등가 보상 필터를 이용한 음질 향상에 관한 연구 (A Study on the Sound Quality Improvement Using the Equal Compensation Filter in Bark-scale for the Cross-talk Cancellation)

  • 김학진;김순협
    • 정보처리학회논문지B
    • /
    • 제11B권3호
    • /
    • pp.345-352
    • /
    • 2004
  • 본 논문에서는 자유음장 모델을 기초로 5.1채널 스피커 시스템의 보상함수를 해석하고, 이를 심리음향에 기초한 바크 스케일(bark scale) 등 가 보상 밴드패스 필터에 적용하여 주파수 제한적인 음질 보상에 대한 실험을 통해 5.1채널 스피커 시스템에서 음향 재현시 나타나는 크로스토크를 제거함으로써 보다 입체적인 음을 재현하는 방법을 제안하였다. 정면 채널과 서라운드 채널의 음원을 기존의 2채널 및 5.1채널 시스템에서 제시하는 음원과 비교를 위하여 음질 평가와 함께 청취자를 대상으로 주관적인 평가를 실시하였다. 실험 결과 \pm30{\circ}$의 정면 스피커를 배치한 돌비 표준 스피커 배치에서 38dB 이상의 분리도를 얻었으며, 전문가 그룹의 음의 확산감에 대한 주관 평가에서는 5점 평가를 기준으로 0.4∼0.5점, 음의 깊이감 평가에서는 0.1∼0.2점이 향상되었다.

두 가지 유형의 바이오마커를 이용한 파킨슨병의 진단과 신경섬유 경로의 특징 분석 (Diagnosis of Parkinson's Disease Using Two Types of Biomarkers and Characterization of Fiber Pathways)

  • 강신태;이욱;박병규;한경숙
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권10호
    • /
    • pp.421-428
    • /
    • 2014
  • 파킨슨병은 뇌의 흑질 영역에서 도파민계 신경이 파괴되는 질병으로 알츠하이머병과 함께 대표적인 퇴행성 뇌 질환이다. 현재까지 병을 완치시킬 수 있는 치료법은 없지만 병의 진행을 완화시킬 수 있는 치료법이 존재하기 때문에 병의 진단이 굉장히 중요하다. 파킨슨병을 진단하기 위한 과거의 연구는 대부분 단일 바이오마커를 이용한 것으로 이러한 방법은 파킨슨병 환자를 높은 정확도로 진단할 수 있지만 정상인에 대한 진단은 상대적으로 낮은 성능의 한계성이 존재한다. 따라서 본 연구에서는 생화학적 바이오마커인 뇌척수액 내의 ${\alpha}$-synuclein 단백질 수치와 영상학적 바이오마커인 확산 텐서 영상의 여러 모수들을 결합하여 특징으로 사용하는 파킨슨병 진단 모델을 개발하고 성능을 평가하였다. 진단을 위해 개발된 모든 모델은 10-fold cross validation 성능평가에서 정확도가 최고 91.3%의 높은 성능을 보였으며, test 성능평가에서는 확산 텐서 영상의 모수들 중 FA와 ${\alpha}$-synuclein 단백질 수치가 결합된 모델, MO와 ${\alpha}$-synuclein 단백질 수치가 결합된 두 모델에서 최고 72%의 정확도 성능을 보여 파킨슨병의 진단에 유용하게 사용될 수 있는 가능성을 제시하였다. 파킨슨병의 진단을 위해 개발된 모델의 영상학적 특징 벡터를 통하여 파킨슨병 환자와 정상인의 신경섬유 경로의 특징을 분석하였다.

Investigation of the U-shape submerged breakwater performance by the finite-different scheme

  • Barzegar, Mohammad
    • Ocean Systems Engineering
    • /
    • 제11권1호
    • /
    • pp.83-97
    • /
    • 2021
  • The submerged U-shape breakwater interaction with the solitary wave is simulated by the Boussinesq equations using the finite-difference scheme. The wave reflection, transmission, and dissipation (RTD) coefficients are used to investigate the U-shape breakwater's performance for different crest width, Lc1, and indent breakwater height, du. The results show that the submerged breakwater performance for a set of U-shape breakwater with the same cross-section area is related to the length of submerged breakwater crest, Lc1, and the distance between the crests, Lc2 (or the height of du). The breakwater has the maximum performance when the crest length is larger, and at the same time, the distance between them increases. Changing the Lc1 and du of the U-shape breakwaters result in a significant change in the RTD coefficients. Comparison of the U-shape breakwater, having the best performance, with the averaged RTD values shows that the transmission coefficients, Kt, has a better performance of up to 4% in comparison to other breakwaters. Also, the reflection coefficients KR and the diffusion coefficients, Kd shows a better performance of about 30% and 55% on average, respectively. However, the model governing equations are non-dissipative. The non-energy conserving of the transmission and reflection coefficients due to wave and breakwater interaction results in dissipation type contribution. The U-shape breakwater with the best performance is compared with the rectangular breakwater with the same cross-section area to investigate the economic advantages of the U-shape breakwater. The transmission coefficients, Kt, of the U-shape breakwater shows a better performance of 5% higher than the rectangular one. The reflection coefficient, KR, is 60% lower for U-shape in comparison to rectangular one; however, the diffusion coefficients, Kd, of U-shape breakwater is 35% higher than the rectangular breakwater. Therefore, we could say that the U-shape breakwater has a better performance than the rectangular one.

Optically Controlled Silicon MESFET Modeling Considering Diffusion Process

  • Chattopadhyay, S.N.;Motoyama, N.;Rudra, A.;Sharma, A.;Sriram, S.;Overton, C.B.;Pandey, P.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.196-208
    • /
    • 2007
  • An analytical model is proposed for an optically controlled Metal Semiconductor Field Effect Transistor (MESFET), known as Optical Field Effect Transistor (OPFET) considering the diffusion fabrication process. The electrical parameters such as threshold voltage, drain-source current, gate capacitances and switching response have been determined for the dark and various illuminated conditions. The Photovoltaic effect due to photogenerated carriers under illumination is shown to modulate the channel cross-section, which in turn significantly changes the threshold voltage, drainsource current, the gate capacitances and the device switching speed. The threshold voltage $V_T$ is reduced under optical illumination condition, which leads the device to change the device property from enhancement mode to depletion mode depending on photon impurity flux density. The resulting I-V characteristics show that the drain-source current IDS for different gate-source voltage $V_{gs}$ is significantly increased with optical illumination for photon flux densities of ${\Phi}=10^{15}\;and\;10^{17}/cm^2s$ compared to the dark condition. Further more, the drain-source current as a function of drain-source voltage $V_{DS}$ is evaluated to find the I-V characteristics for various pinch-off voltages $V_P$ for optimization of impurity flux density $Q_{Diff}$ by diffusion process. The resulting I-V characteristics also show that the diffusion process introduces less process-induced damage compared to ion implantation, which suffers from current reduction due to a large number of defects introduced by the ion implantation process. Further the results show significant increase in gate-source capacitance $C_{gs}$ and gate-drain capacitance $C_{gd}$ for optical illuminations, where the photo-induced voltage has a significant role on gate capacitances. The switching time ${\tau}$ of the OPFET device is computed for dark and illumination conditions. The switching time ${\tau}$ is greatly reduced by optical illumination and is also a function of device active layer thickness and corresponding impurity flux density $Q_{Diff}$. Thus it is shown that the diffusion process shows great potential for improvement of optoelectronic devices in quantum efficiency and other performance areas.

CFD-DEM 연동을 통한 함정용 채프운의 시공간 분포 해석 (Numerical Simulation of Spatiotemporal Distribution of Chaff Clouds for Warship Defense using CFD-DEM Coupling)

  • 정욱진;김문홍;손동우
    • 한국전산구조공학회논문집
    • /
    • 제36권2호
    • /
    • pp.93-103
    • /
    • 2023
  • 수많은 함정용 채프들은 폭발에 의해 확산되어 채프운을 형성하며, 채프운은 허위 레이더 반사 단면적을 생성하여 적의 레이더를 기만한다. 본 논문에서는 전산유체역학-이산요소법 단방향 연동 기법을 기반으로 공기 중에 분포하는 함정용 채프운의 시공간 분포를 해석하는 수치적 프레임워크를 구축하고 바람의 방향과 속도, 채프 카트리지의 초기 각도와 폭발 압력이 채프운 분포에 미치는 영향을 분석하였다. 채프운의 확산은 폭발에 의한 방사형 확산, 난류와 충돌에 의한 전 방향 확산, 낙하 속도 차이에 의한 중력 방향 확산과 같이 세 단계로 구분되는 것을 확인하였다. 바람은 채프운의 평균 위치를 이동시켰으며, 항력에 의한 확산 효과는 나타나지 않았다. 카트리지 초기 각도에 따라 폭발에 의한 방사형 확산 방향이 달라졌으며, 각도가 지면과 수직에 가까울수록 더 넓게 확산되었다. 폭발 압력이 증가할수록 채프운은 더 넓게 확산되었으나 중력 방향으로는 분포 차이가 작았다.

$ SF_6$가스의 전자에너지 분포함수에 관한 연구 (A Study on the electron energy diffusion function of the sulphur hexaflouride)

  • 김상남;하성철
    • 조명전기설비학회논문지
    • /
    • 제13권2호
    • /
    • pp.95-101
    • /
    • 1999
  • $ SF_6$ 가스의 전자에너지 분포함수를 평균에너지 평형 영역에 대하여 E/N=500~800[Td]에서 해석하였다. 본 논문은 저자들에 의해 결정된 충돌 단면적을 사용하여 몬테칼로 시뮬레이션과 볼쯔만 방정식에 의해 E/N=150~800[Td]범위에서 계산된 $ SF_6$ 가스의 전자 수송 특성과 TOF법에서 구한 전자군 파라미터 값들을 나타냈다. 전자이동속도 전자 이온화 또는 부착계수, 종.횡 방향 확산계수 등의 전자군 파라미터 값들은 E/N 범위에서 실험 치와 이론 치가 일치하였다. 전자사태의 특성은 전자에너지의 비평형 영역에서 고려되었다.

  • PDF

인쇄기판형열교환기 핵심치수 구조설계 (Structural Design for Key Dimensions of Printed Circuit Heat Exchanger)

  • 김용완;강지호;사인진;김응선
    • 한국압력기기공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.24-31
    • /
    • 2018
  • The mechanical design procedure is studied for the PCHE(printed circuit heat exchanger) with electrochemical etched flow channels. The effective heat transfer plates of PCHE are assembled by diffusion bonding to make a module. PCHE is widely used for industrial applications due to its compactness, cost efficiency, and serviceability at high pressure and/or temperature conditions. The limitations and technical barriers of PCHE are investigated for application to nuclear components. Rules for design and fabrication of PCHE are specified in ASME Section VIII but not in ASME Section III of nuclear components. Therefore, the calculation procedure of key dimensions of PCHE is defined based on ASME section VIII. The effective heat transfer region of PCHE is defined by several key dimensions such as the flow channel radius, edge width, wall thickness, and ridge width. The mechanical design procedure of key dimensions was incorporated into a program for easy use in the PCHE design. The effect of assumptions used in the key dimension calculation on stress values is numerically investigated. A comparative analysis is done by comparing finite element analysis results for the semi-circular flow channels with the formula based sizing calculation assuming rectangular cross sections.