• Title/Summary/Keyword: Cross contamination

Search Result 264, Processing Time 0.037 seconds

Verification of the HACCP System in School Foodservice Operations - Focus on the Microbiological Quality of Foods in Non-Heating Process - (학교급식소의 HACCP 시스템 적합성 검증(II) -비가열조리 공정을 중심으로-)

  • 전인경;이연경
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.7
    • /
    • pp.1154-1161
    • /
    • 2004
  • The objective of this study was to evaluate microbiological Quality of HACCP application in elementary school foodservice operations. Microbiological Quality of utensils and non-heated foods such as salad was measured two times at five elementary schools in Daegu. The two experimentations differed in that after the first experimentation employees were educated and trained on HACCP based sanitation standards with a goal of improving microbiological Quality of foodservice. Microbiological Quality, time, and temperature were evaluated at three critical control points (CCPs): washing and disinfecting, personal hygiene and non-cross contamination. Micro-biological Quality was assessed using 3M petrifilm to measure total plate count and coliform group. The first experimentation showed low microbiological Quality due to cross contamination of utensils and cooking gloves; high microbiological count of the garlic, powdered red pepper, and ginger; and not thoroughly washing and disinfecting vegetables. In the second experimentation, microbiological Quality was greatly improved by washing and thoroughly disinfecting raw ingredients and utensils, and using good personal hygiene. However, microbiological Quality of seasonings was still low. Immediate corrective actions were required in one of the foodservice operations that was assessed. These results strongly suggest that foodservice operations should address non-heated food Quality. It is essential to measure microbiological Quality regularly and continually train and retrain employees on hand washing and disinfecting raw ingredients. Further studies are needed to determine whether pathogens are present in raw vegetables and seasonings.

Clinical Efficacy of Latex Cover for Dental Handpiece (치과 핸드피스용 감염방지구의 임상적 효용성)

  • Lee, Ki-Ho;Paek, Dong-Heon
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.237-245
    • /
    • 2009
  • The purpose of this study was to investigate the clinical efficacy of latex cover developed for dental handpiece on contamination of microorganisms during dental treatment and to determine whether it can be an alternative to conventional sterilization such as autoclaving. E. fecaelis was used as a experimental microorganism instead of oral flora. Experimental bowl with 2 cm of rectangular cavity was fabricated for handpiece operating instead of oral cavity. Latex covers ($Orokeeper^{(R)}$, Orobiotech Co., Korea) and several handpieces were used after sterilization by autoclave. Four experiments were performed to evaluate bacterial contamination related with (1) various parts of dental handpiece, (2) swabbing time with alcohol sponge, (3) postoperative air-water spraying time and (4) consecutive use of latex covers without autoclaving. The results show that face of handpiece uncovered with latex cover was severely contaminated than the covered area and that most bacteria were removed by swabbing face and head area of dental hand-piece and by air-water spraying more than 15 seconds nearly up to the level of sterilization. Conclusively it can be suggested that use of latex cover for handpiece during dental procedure, swabbing with alcohol sponge is air-water spraying for more than 15 seconds after use of dental handpiece should be very useful and practical for prevention of cross infection and should be an alternative method for the sterilization of dental handpiece under some difficult situations not being able to sterilize a handpiece with autoclave.

Perception of Importance and Performance in the Infection Control of Visiting Nursing Personnel in Public Health Centers (보건소 방문간호요원의 감염관리에 대한 중요성 인지도 및 실천도)

  • Kim, Kum-Nam;Oh, Jjn-Joo
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.389-398
    • /
    • 2000
  • The work of visiting nursing personnel consists mostly of direct nursing and it is absolutely necessary that training of the nursing personnel for infection control be emphasized because most of patients are composed of elderly people with chronic diseases and malnutrition who are highly susceptible to infection. Accordingly. this study was designed to provide basic data for the development of an infection control program in public health centers as well as the promotion of perception and performance of infection control by analysing the perception of importance and performance in the infection control of visiting nursing personnel who carry out visiting nursing services. The subjects of this study consisted of a number of visiting nursing personnel working for 15 public health centers. 15 health-center branches. and 16 health clinics. The collection of data was grounded on a questionnaire method. The questionnaire breaks down to 8 questions about general characteristics and 108 questions in connection with the perception and performance of infection control. The results of this study are as follows: 1. 82 subjects (78.1%) responded that it is necessary to control infection. 79 subjects(75.3%) responded that education is necessary for infection control. 50 respondents (47.6%) answered in the affirmative in regard to the role of infection carriers. 2. The mean score for the perception of importance in infection control was 4.55 and that performance accounts for 4.03. this turns out to be very high. 3. In terms of the perception of importance per each field of infection control. medication. the management of contamination and sterilization, the control of environments and instruments. washing hands and individual hygiene as well as the prevention of cross-infection and the supervision of infection stand at 4.72. 4.64. 4.60. 4.58. 4.52 and 4.21 respectively. In terms of performance. the supervision of infection. the control of environments and instruments, individual hygiene and the prevention of cross infection. medication. washing hands, and the management of contamination and sterilization was 4.21. 4.12. 4.10. 4.03. 3.91 and 3.81 respectively. 4. In terms of the correlation between the perception of importance and the performance of infection control. the score stands high in all fields: this means the high perception of importance leads to high performance statistically (P< .05). 5. In terms of the perception of importance in general characteristics. there is no significant difference while the form of working places. working career and the career as visiting nursing personnel show a significant difference in terms of performance(P< .05). From the results. it is suggested that the visiting nursing personnel should be constantly educated with the aid of the development of infection control programs and that instructions and instruments for the management of infection should be worked out so as to enhance the performance of infection control on the part of nurses in applicable communities.

  • PDF

Factors Related to Sanitary Management Performance Based on HACCP System in School Foodservice - Seoul, Gyeonggi, Kangwon and Choongchung Areas in Korea - (HACCP 시스템 적용 학교급식 위생관리 수행수준에 영향을 미치는 요인 - 서울, 경기, 강원, 충청지역을 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Sim-Yeol
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.6
    • /
    • pp.817-830
    • /
    • 2009
  • The purpose of this study was to analysis the sanitary management performance based on HACCP system for school foodservice. This study was carried out from September 2008 until December 2008 and is targeted towards schools' dietitians that work at schools with school foodservice. The regional distribution of this research is as follows; 377 schools in Seoul, 648 schools in Gyeonggido, 160 schools in Kangwondo, 438 schools in Choongchungdo equaling 1,623 schools in total. When school foodservices were put through sanitation management achievement level analysis applied by the HACCP system, results displayed that management of temperature (3.96 points), time (4.08 points), and cross-contamination (4.07 points) were all below the average achievement level. HACCP system's achievement level based on the TQM showed that areas for strategy development, leadership, information and analysis had low achievement levels. Achievement levels for CCP are quality check, delivery/distribution process, sterilization/cleansing of food's contact surface. As a result of multiple regression analysis of the factors that influenced sanitation management achievement level of school foodservice HACCP system; sanitary job standard showed 35.6% and CCP achievement levels showed 26.8% explanatory rate. In particular, Kangwondo's number of foodservice provided to per cook was small. Also, the better the processing management was assessed, the higher the sanitary job standard achievement level became resulting to a explanatory rate of 39.5%. Elementary schools showed a higher explanatory rate of 37.0% than middle and high schools. CCP achievement levels in middle and high schools with self-operated foodservice had a 28.0% variable explanatory rate, which was the highest. The better the drainage system, leadership and assessments turned out to be, the higher the CCP achievement levels became. In summary, to revitalize HACCP system that is based on the TQM, it is considered that proper database of HACCP system for school foodservice's sanitation management be constructed and more emphasis should be put on strategy development to improve customers' satisfactory level. In addition, improvements in achievement levels of time, temperature, and cross-contamination for sanitary job standard and CCP achievement level are essential.

Investigation of Microbial Contamination in Oenanthe javanica at Postharvest Environments (미나리(Oenanthe javanica) 수확 후 처리 환경에서의 위생지표세균 및 병원성 미생물 오염도 조사)

  • Kim, Yeon Rok;Lee, Kyoung Ah;Choi, In-Wook;Lee, Young-Ha;Kim, Se-Ri;Kim, Won-Il;Ryu, Song Hee;Lee, Hyo Sub;Ryu, Jae-Gee;Kim, Hwang-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.268-277
    • /
    • 2014
  • This study assessed microbiological hazards at postharvest stage of dropwort farms (A, B, C, D, E, F, G, H, I) located in 4 different areas in Korea. The samples were assessed for sanitary indication bacteria (total aerobic bacteria, coliform, and Escherichia coli) and pathogenic bacteria (Escherichia coli O157:H7, Listeria monocytogenes, Staphylococcus aureus and Bacillus cereus). Total aerobic bacteria and coliform in 9 dropwort farms were detected at the levels of 0~7.00 and 0~4.25 log CFU/g, mL, of $100cm^2$. In particular, microbial contamination in worker's hand showed higher than cultivation environment factors. Escherichia coli was detected in several farms of soil, irrigation water, washing water and worker's hand and also, dropwort in these farms was contaminated with E. coli (positive reaction). In case of pathogenic bacteria, B. cereus was detected at the highest levels in soil. S. aureus was detected qualitatively from only one sample of dropwort washed by water. E. coli O157:H7 and L. monocytogenes were not detected. Although dropwort pass through 2 process (trimming and washing), the microbial contamination was not differ significantly before and after which indicates that current washing system was not effect on reduction of microorganism. From these results, the postharvest environment and workers have been considered as cross-contamination factors. Thus, processing equipments and personal hygiene should be managed to reduce the microbial contamination of dropwort. Accordingly management system such as good agricultural practices (GAP) criteria is needed for the safety of dropwort

Monitoring for Microbiological Quality of Rice Cakes Manufactured by Small-Scale Business in Korea (소규모 가공경영체 떡류의 생산과정에 따른 미생물학적 품질조사를 위한 모니터링)

  • Han, Sangha;Kim, Kyeongjun;Byun, Kye-Hwan;Kim, Duk-Hyun;Choi, Song-yi;Ha, Sang-do
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.5
    • /
    • pp.400-406
    • /
    • 2021
  • The purpose of this study was to evaluate the microbial contamination level of Korean traditional rice cakes (Garaetteok, Injeolmi, Gyeongdan), as well as manufacturing environment of small-sized businesses in Korea. The contamination levels of total aerobic bacteria, coliforms, and Bacillus cereus in raw materials were 3.76-4.48, 2.21-4.14, and 1.02-1.15 log CFU/g respectively. On the other hand, Escherichia coli was not found. It has been found that the contamination level of total aerobic bacteria, coliforms, and B. cereus in the raw material decreased after the washing process, but it increased again during the soaking and grinding process. However, after the steaming stage, the contamination level increased again during the molding and cooling process, suggesting the need to take cautions in managing cooling water and molded rice cakes in the process. These results suggest that the safe management of cooling water and taking cautions in the drying process after steaming of rice cakes are necessary for controlling cross-contamination. No E. coli was detected during the manufacturing process involving all tested rice cakes. The microbial contamination level of manufacturing environment such as rice grinder and rice cake forming machine was high. Therefore, in terms of food safety strategy, it is necessary to consider introducing systematic cleansing and disinfection procedure to processing equipment and environment for the sake of reducing microbiological risks.

Industrial-Scale Production of High-Purity Antihemophilic Factor IX from Human Plasma (사람 혈장으로부터 고순도 혈액응고 제9인자의 산업적 생산)

  • Kang, Yong;Choi, Yong-Woon;Sung, Hark-Mo;Sohn, Ki-Whan;Shin, Jeong-Sup;Kim, In-Seop
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • The use of antihemophilic factor IX complex has been associated with a variety of thrombotic complications, the major cause of which was the contamination of thrombogenic proteins such as vitamin K-dependent clotting factors II, VII, and X. In order to produce a commercial factor IX (GreenNine VF) free from thrombogenic potential, industrial-scale production process for high-purity factor IX from human plasma has been developed. The purification process contains cryo-precipitation, DEAE-sephadex A-50 anion-exchange chromatography, DEAE-toyopearl 650M anion-exchange column chromatography, heparin-sepharose 6FF affinity column chromatography, and CM-sepharose FF cation-exchange column chromatography. Also the process includes two viral inactivation and removal procedures, solvent/detergent treatment and nanofiltration using Viresolve NFP filter. The purification yield was 35.4%. The specific activity in the purified concentrate was 190.8 IU/mg which exceeded that in the factor IX complex (FacNine) by a factor of 48. The activities of factor II, VII, and X were not detected in GreenNine VF. SDS-PAGE analysis showed that GreenNine VF had the highest purity in comparison with commercially available high purity factor IX concentrates, Mononine, Octanyne, Berinin HS, and Immunine STIM plus 600. One batch size of the production was 2,400 vials of 250 IU product or 1,200 vials of 500 IU product from 1,600 L cryo-poor plasma.

Pseudoepidemic of Mycobacteria Other Than Tuberculosis (MOTT) Due to Contaminated Bronchoscope (기관지경 오염에 의한 비결핵항산균증의 위발생)

  • Kwak, Seung-Min;Kim, Se-Kyu;Jang, Joong-Hyun;Lee, Hong-Lyeol;Lee, Yi-Hyung;Kim, Sung-Kyu;Lee, Won-Young;Jeong, Yoon-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • Background: The development of the flexible fiberoptic broncoscope by Ikeda was an important technologic advance in the diagnosis and management of patients with pulmonary disease. But, cross contamination related to fiberoptic bronchoscope was reported in cases involving tubercle bacilli, MOTT and other agents. Therefore, cleaning and disinfecting of fiberoptic bronchoscope requires careful attention. Methods: From September 1991 to May 1992, medical records of all patients with positive culture for MOTT in bronchial washing specimens were reviewed. Also to evaluate bactericidal effect of 2% glutaraldehyde, culture was performed after inoculum of MOTT, Serratia marsescens and Pseudomonas aeruginosa to the disinfectant solution. Results: In 2% alkaline glutaraldehyde, MOTT was not survived only after 30 minute exposure, but P. aeruginosa and S. marsescens were rapidly inactivated with no survivors after exposure to 2% glutaraldehyde. Since vigorous mechanical cleansing and more than 30 minute of contact time within washing machine, no more outbreak was observed. Conclusions: It is also very important that bronchoscopes must be meticulously cleaned after each procedure and more than 30 minute exposure would be required for eradication of MOTT with 2% glutaraldehyde. However even the most strictly applied infection control measures cannot exclude contamination completly and clinicians have to stay alert to this possibility. Prompt detection of pseudoepidemics is possible if abrupt increase in isolation rates, especially if they involve unusual or generally nonpathogenic organisms, are readily recognized.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT CURED GLASS IONOMER CEMENTS TO CONTAMINATED DENTIN (상아질 표면상태에 따른 광중합형 글래스아이오노머 시멘트의 전단결합강도에 관한 연구)

  • Kim, Kyoung-Hwa;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.609-621
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three light-cured glass ionomer cements to blood contaminated bovine dentin. The materials used in this study were Fuji II LC, Dyract and Variglass VLC. The dentin conditioners were 10% polyacrylic acid, 10% maleic acid and 10% phosphoric acid. 180 lower anterior bovine teeth were selected in this study. The teeth were embedded in acrylic resin and were grounded with 320 to 600 grit silicon carbide paper to create a flat dentin surface. The teeth were divided into SIX groups. The experimental procedures in six groups were as follows; Group l(GF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment. Group 2(BGF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment and blood contamination. Group 3(MD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment. Group 4(BMD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment and blood contamination. Group 5(PV) : Samples bonded to dentin surface with Variglass VLC after 10% phosphoric acid treatment. Group 6(BPV) : Samples bonded-to dentin surface with Variglass VLC after 10% phosphoric acid treatment and blood contamination. Group 1,3 and 5 were classified into the control groups, while group 2,4 and 6 were classified into the experimental groups. Each group contained 30 samples. After 24 hours water storage at $37^{\circ}C$, all smples were subjected to a shear load to fracture at a cross head speed of 1.0 mm/min with Instron universal testing machine(No. 4467). Debonded surfaces were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically at the 95% confidence level with Student's t-test. The following results obtained; 1. Shear bond strengths were higher in the control groups(1,3,5 group) than in the experimental groups(2,4,6 group). 2. The shear bond strength of group 5(PV) was the highest in the control groups, and the group 5 was significantly higher than the group l(GF) on the shear bond strength. 3. The group 4(BMD) was the highest on the shear bond strength, and the group 2(BGF) was the lowest in the experimental groups. The group 4(BMD) and 6(BPV) showed a significant difference with the group 2 on the shear bond strength. 4. All the groups showed an adhesive-cohesive failure. except the group 2(BGF) showing adhesive failure.

  • PDF