• Title/Summary/Keyword: Cross Talk

Search Result 251, Processing Time 0.069 seconds

Enigma of Small Peptides Ubiquitin and SUMO in Plants

  • Seo, Hak Soo
    • Korean Journal of Breeding Science
    • /
    • v.42 no.4
    • /
    • pp.339-343
    • /
    • 2010
  • Post-translational covalent modifications by small molecules or peptides remodel target proteins. One such modification, made by ubiquitin or small ubiquitin-related modifier (SUMO), is a rapidly expanding field in cell signaling pathways. Ubiquitin attachment controls the turnover and degradation of target proteins while SUMO conjugation regulates their activity and function. Recent studies report many examples of cross-talk between ubiquitin and SUMO pathways, indicating that the boundary is no longer clear. Here, we review recent progress concerning how ubiquitin and SUMO participate in new regulatory roles in plant cell, and how ubiquitination and sumoylation control plant growth and development.

Optical issues of OLED displays with a photo sensor for in-pixel optical feedback

  • Oepts, Wouter;Giraldo, Andrea;Lifka, Herbert;Fish, David;Young, Nigel
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.968-971
    • /
    • 2005
  • Amorphous silicon photo diodes incorporated in a polyLED stack are applied in in pixel opticalfeedback to compensate for polyLED degradation. Large quantum efficiencies and perfect linearity are demonstrated. The photosensitivity is in agreement with optical modeling of the stack. A new scheme for ambient and cross talk light cancellation is given.

  • PDF

The EST Study of the Peri-implanting Porcine Embryos (Peri-implanting 단계의 돼지배아 EST 연구)

  • Kwak, In-Seok
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.587-592
    • /
    • 2009
  • A dramatic morphological change of embryos occurs at peri-implantation. Maternal and embryonic cross-talk during this period, initiated by signals from embryo(s), provides signals for maternal recognition of pregnancy and establishing and maintaining the pregnancy. However, the cellular, biochemical and genetic processes that direct embryo remodeling in mammalian species are not well studied or understood. In order to identify potential genes responsible for morphological change and cross-talk between embryo and uterus, an initial EST analysis was performed. A catalog of expressed genes (Transcriptome) from the d12 peri-implanting porcine embryos was constructed. Six clones were chosen from the initial ESTs for elucidation of their expression patterns during embryogenesis in early pregnancy. A number of these genes demonstrated unique expression profiles in a tissue, cell-type, and temporal fashion, indicating dynamic regulation of embryonic and endometrial gene expressions at different stages of pregnancy. Cross-talk between the embryo and endometrium of the pregnant uterus has provided a suitable micro-environment for the embryo's rapid and dramatic morphological changing process at the peri-implantation stage.

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

Identification of Pitfalls Related to the Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Time of Flight Mass Spectrometry (액체크로마토그래프-질량분석기를 이용한 정성 및 정량 오류의 확인)

  • Kwon, Jin-Wook;Cho, Yoon-Jae;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.3
    • /
    • pp.230-237
    • /
    • 2015
  • BACKGROUND: To identify the sources of inaccuracy in LC/MS/MS methods used in the routine quantitation of small molecules are described and discussed. METHODS AND RESULTS: Various UPLC coupled to triple quadrupole mass spectrometer and time of flight (TOF) were used to identify the potential sources of inaccuracy and inducing the pitfalls of qualification and quntitation during the veterinary drug residue analysis. Some of stable isotope labelled veterinary drugs, which were used as internal standards, presented "cross-talk", regardless of manufactures of mass spectrometer and types of spectrometer. Group of sulfonamides also presented inaccuracy qualification and quantitation due to the multi-residue analytical method with the same fragment ions at the close retention times. CONCLUSION: The phenomena of "cross-talk" occurring between subsequently monitored transition from stable isotope labelled and isotope non-labelled authentic chemical were identified. To prevent errors and achieve more accurate data during the analysis of small molecules by LC/MS/MS SRM method, Followings should be taken care of and kept checking; purity and concentration of stable isotope as an internal standard, prevention of carry-over during the separation in column, minimizing the ion suppression by matrix effect, identification of retention time, precursor ion and product ion, and full knowledge of data processing including smoothing and peak integration.

Algorithm and experimental verification of underwater acoustic communication based on passive time reversal mirror in multiuser environment (다중송신채널 환경에서 수동형 시역전에 기반한 수중음향통신 알고리즘 및 실험적 검증)

  • Eom, Min-Jeong;Oh, Sehyun;Kim, J.S.;Kim, Sea-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.167-174
    • /
    • 2016
  • Underwater communication is difficult to increase the communication capacity because the carrier frequency is lower than that of radio communications on land. This is limited to the bandwidth of the signal under the influence of the characteristics of an ocean medium. As the high transmission speed and large transmission capacity have become necessary in the limited frequency range, the studies on MIMO (Multiple Input Multiple Output) communication have been actively carried out. The performance of the MIMO communication is lower than that of the SIMO (Single Input Multiple Output) communication because cross-talk occurs due to multiusers along with inter symbol interference resulting from the channel characteristics such as delay spread and doppler spread. Although the adaptive equalizer considering multi-channels is used to mitigate the influence of the cross-talk, the algorithm is normally complicated. In this paper, time reversal mirror technique with the characteristic of a self-equalization will be applied to simplify the compensation algorithm and relieve the cross-talk in order to improve the communication performance when the signal transmitted from two channels is received over interference on one channel in the same time. In addition, the performance of the MIMO communication based on the time reversal mirror is verified using data from the SAVEX15(Shallow-water Acoustic Variability Experiment 2015) conducted at the northern area of East China Sea in May 2015.