• Title/Summary/Keyword: Cross Patch

Search Result 112, Processing Time 0.024 seconds

Design and Fabrication of a Dual Polarized Load-bearing Microstrip Antenna (이중편파 하중 지지형 마이크로스트립 안테나 설계 및 제작)

  • 이라미;이정수;박위상;박현철;황운봉
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.125-135
    • /
    • 2001
  • A 8$\times$4 microstrip antenna array is designed at 5.3 GHz and its characteristics are investigated with respect to the application in dual polarized synthetic aperture radars. The design is focused on the achievement of a wide bandwidth, a high polarization purity, a low loss, a good isolation and some mechanical requirements suitable for the application. The antenna is fed by a -3 dB tapered feed network, and is composed of dual polarized SSFIP (Strip-Slot-Foam-Inverted Patch) elements with honeycomb and shielding plane. Simulation results for the antenna array are presented and compared with measurements. It is observed that the antenna shows a bandwidth of 80 MHz, a polarization isolation better than 20 dB, an isolation of 40 dB, and good mechanical characteristics.

  • PDF

Clinical experience of open heart surgery: 12 cases (개심술 치험 보고: 12예)

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 1983
  • The report is concerned to our experience of 12 cases of open heart surgery under the extracorporeal circulation at the Department of Thoracic and Cardiovascular Surgery, Chosun University Hospital during the period between Nov, 1979 and April, 1983. 1. There were 4 cases of congenital anomaly and 8 cases of acquired heart disease. 2. There were 6 male and 6 female patients with a mean age of 20 years. [range 9 to 33 years]. 3. The cases induced 2 ventricular septal defect, 2 atrial septal defects and 8 acquired valvular heart diseases. 4. The surgical managements were 2 primary repair for atrial septal defect and 2 patch closure for ventricular septal defect, 1 triple valve replacement [AVR MVR TVR], 1 aortic valve replacement, 4 double valve replacement [AVR MVR] and 2 open mitral commissurotomy for pure mitral stenosis. 5. The average cardiopulmonary bypass time was 61.5 minutes for congenital heart disease and 201.4 minutes for acquired valvular heart disease and the average aortic cross clamping time was 36.75 minutes for the former and 165.6 minutes for the latter. 6. Postoperatively, there were 1 Alopecia, 1 Electric burn and 1 wound infection as complication. 7. Overall operative mortality was 8.3%. 7. All patients received valve replacement were recommended anticoagulation with persantin.

  • PDF

Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan - (방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사)

  • Lee, Jeong-Cheol;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

Navigation and Find Co-location of ATSR Images

  • Shin, Dong-Seok;Pollard, John-K.
    • Korean Journal of Remote Sensing
    • /
    • v.10 no.2
    • /
    • pp.133-160
    • /
    • 1994
  • In this paper, we propose a comprehensive geometric correction algorithm of Along Track Scanning Radiometer(ATSR) images. The procedure consists of two cascaded modules; precorrection and fine co-location. The pre-correction algorithm is based on the navigation model which was derived in mathematical forms. This model was applied for correction raw(un-geolocated) ATSR images. The non-systematic geometric errors are also introduced as the limitation of the geometric correction by this analytical method. A fast and automatic algorithm is also presented in the paper for co-locating nadir and forward views of the ATSR images by using a binary cross-correlation matching technique. It removes small non-systematic errors which cannot be corrected by the analytic method. The proposed algorithm does not require any auxiliary informations, or a priori processing and avoiding the imperfect co-registratio problem observed with multiple channels. Coastlines in images are detected by a ragion segmentation and an automatic thresholding technique. The matching procedure is carried out with binaty coastline images (nadir and forward), and it gives comparable accuracy and faster processing than a patch based matching technique. This technique automatically reduces non-systematic errors between two views to .$\pm$ 1 pixel.

Neutrophil oxidative burst as a diagnostic indicator of IgG-mediated anaphylaxis

  • Won, Dong Il;Kim, Sujeong;Lee, Eun Hee
    • BLOOD RESEARCH
    • /
    • v.53 no.4
    • /
    • pp.299-306
    • /
    • 2018
  • Background IgG-mediated anaphylaxis occurs after infusion of certain monoclonal antibody-based therapeutics. New in vitro tests are urgently needed to diagnose such reactions. We investigated whether allergens trigger neutrophil oxidative burst (OB) and if neutrophil OB occurs due to allergen-specific IgG (sIgG). Methods Neutrophil OB was measured by dihydrorhodamine 123 flow cytometry using a leukocyte suspension spiked with a very small patch of the allergen crude extract, Dermatophagoides farinae (Der f). The mean fluorescence intensity ratio of stimulated to unstimulated samples was calculated as the neutrophil oxidative index (NOI). Results The Der f-specific NOI (Der f-sNOI) showed a time-dependent increase after Der f extract addition. At 15 min activation, higher Der f-sIgG levels were associated with lower Der f-sNOI values in 31 subjects (P<0.05). This inverse relationship occurs due to the initial blocking effect of free Der f-sIgG. Additionally, neutrophil OB was nearly absent (Der f-sNOI of -1) in two cases: a subject with undetectable Der f-sIgG levels and washed leukocyte suspensions deprived of Der f-sIgG. Conclusion Allergens can trigger neutrophil OB via preexisting allergen-sIgG. Neutrophil OB can be easily measured in a leukocyte suspension spiked with the allergen. This assay can be used to diagnose IgG-mediated anaphylaxis.

X-band Microstrip 4×4 Broadband Circularly Polarized Array Antenna Using Sequential Rotation Divider Structure (시퀀셜 로테이션 분배기 구조를 이용한 X-band 마이크로스트립 4×4 광대역 원형 편파 배열 안테나)

  • Kim, Jung-Han;Kim, Joong-Kwan;Kim, Yong-Jin;Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.158-165
    • /
    • 2007
  • In this paper, the circularly polarized $4{\times}4$ array antenna is proposed for the X-band. A single antenna consists of square patch and unequal cross-aperture coupled feeding. The RHCP(Right Handed Circularly Polarization) is generated by unequal cross-aperture coupled feeding. By reducing space among elements of way antenna from 0.8 ${\lambda}_0$ to 0.45 ${\lambda}_0$, the mounting area of array antenna is miniaturized. The $2{\times}2$ array antenna is designed using sequential rotation feeding network. The good level of gain, axial ratio, and impedance bandwidth are achieved. The $4{\times}4$ array antenna is extended by ${\lambda}/4$ transformer and T-junction power divider. The simulated maximum radiation gain is 15.09 dBi at 10 GHz. The simulated 3 dB Axial Ratio bandwidth is from 9.05 to 10.4 GHz(13.5%). Also the measured impedance bandwidth($VSWR{\leq}2$) of manufactured $4{\times}4$ array antenna is from 8.45 to 11.84 GHz(33.9%). The measured maximum radiation gain is 11.10 dBi at 10 GHz. The measured 3 dB Axial Ratio bandwidth is from 9.42 to 10.47 GHz(10.5%).

Design and Fabrication of Dual Linear Polarization Antenna for mmWave Application using FR-4 Substrate

  • Choi, Tea-Il;Yoon, Joong-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2022
  • In this paper, we propose 1×2 array antenna with dual linear polarization characteristics for mmWave band operation. The proposed antenna is designed two microstirp feeding structure and FR-4 substrate, which is thickness 0.4 mm, and the dielectric constant is 4.3. The size of 1×2 array antenna is 2.33 mm×2.33 mm, and total size of array antenna is 13.0 mm×6.90 mm. From the fabrication and measurement results, bandwidths of 1.13 GHz (28.52~29.65 GHz) for port 1 and 1.08 GHz (28.45~29.53 GHz) for port 2 were obtained based on the impedance bandwidth. Cross polarization ratios are obtained from 7.68 dBi to 16.90 dBi in case of vertical polarization, and from 7.46 dBi to 15.97 dBi in case of horizontal polarization for input port 1, respectively. Also, cross polarization ratios are obtained from 8.59 dBi to 13.72 dBi in case of vertical polarization and from 9.03 dB to 14.0 dB in case of horizontal polarization for input port 2, respectively.

Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping (압전감쇠를 통한 압전단일패널의 전달 소음저감성능)

  • 이중근;김재환;김기선;이형식
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The possibility of a noise reduction of piezoelectric single Panels is experimentally studied. Piezoelectric single panel is basically a plate structure on which piezoelectric patch with shunt circuit is mounted. The use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. Piezo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of single Panel is tested on an acoustic tunnel. The tunnel is a tube with a square cross section and a loud speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across Panels is measured. By enabling the piezoelectric shunt damping noise reduction is achieved at the resonance frequencies as well. Piezoelectric single panel with piezoelectric shunt damping is a promising technology for noise reduction in a broadband frequency.

  • PDF

Surgical Repair of Inferior Sinus Venosus Defect - A Report Four Cases- (하정맥동형 심방중격결손의 외과적처지 -4례 보고-)

  • 최형호;김천석;윤향석;최종범;최순호
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.168-172
    • /
    • 1998
  • Inferior sinus venosus defect is a rare lesion in which there is a large interatrial communication adjacent to the atrial connection of the inferior caval vein. The defect is located posteriorly and inferiorly, outside the confines of the true atrial septum, and partial anomalous pulmonary venous connections are the rule. We underwent surgical repair in four patients with inferior sinus venosus defect and partial anomalous pulmonary venous return. There were three males and one female with an age range from four months to 25 years. A cross- sectional echocardiogram and cardiac catheterization had been performed preoperatively in all patients, but the correct diagnosis had been made in only one case. Surgical repair was indicated due to congestive heart failure, and one patient of 4-month-old needed urgent operation. The repair was accomplished by suturing a untreated autologous pericardial patch to the right of the pulmonary veins, so that the defect was closed and all the pulmonary venous blood was directed to the left atrium. The preoperative knowledge of the unusual anatomy allows the surgeon to repair the anomaly without difficulties. For the patients in whom interatrial communication and anomalous pulmonary venous return are suggested, surgeon has to pay careful attention to the anatomical landmarks to avoid incorrect placement of the patch.

  • PDF

A Study of Dual-Frequency Microstrip Patch Antenna (이중공진 마이크로스트립 패치 안테나에 관한 연구)

  • 장준영;김준모;윤영중;엄순영;전순익
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.515-525
    • /
    • 1998
  • In this paper, for both transmission and reception with single antenna system of satellite communication, dual-frequency antennas which operate simultaneously at 12.5 GHz and at 14.25 GHz are designed, constructed and measured. Also by using dual feeding structure, the problems of single-fed dual-frequency antenna such as the separation of transmitting and receiving signals and single polarization, are solved. Microstrip patch as a radiation element of dual-fed dual-frequency antenna has width and length which are the resonance lengths of the corresponding frequencies for transmission and reception, respectively. The effects of the feed line on the other frequency feeding are minimized with the optimal matching scheme for the feed lines. For solving the space problems of dual-fed two-dimensional array antennas, microstrip-line and coaxial probe feedings are used for each frequency and a two-dimensional $2\times2$ array antenna was designed and measured their characteristics. The experimental results show that errors of resonance frequencies are less than 1.44%, the return losses are less than -21 dB and the isolations between two feeding ports are less than -21 dB. The characteristics of radiation patterns of dual frequency microstrip antenna are measured and evaluated. The directivities, sidelobe levels and cross polarizations are also measured and compared with the simulations. The results show some errors due to the misalignment of coaxial probe feeding.

  • PDF