• 제목/요약/키워드: Cross Containment

검색결과 16건 처리시간 0.025초

열화 및 공극을 고려한 원전 격납건물의 다층쉘요소모델과 내진성능 한계상태 (Multi-Layered Shell Model and Seismic Limit States of a Containment Building in Nuclear Power Plant Considering Deterioration and Voids)

  • 남현웅;홍기증
    • 한국지진공학회논문집
    • /
    • 제28권4호
    • /
    • pp.223-231
    • /
    • 2024
  • For the OPR1000, a standard power plant in Korea, an analytical model of the containment building considering voids and deterioration was built with multilayer shell elements. Voids were placed in the vulnerable parts of the analysis model, and the deterioration effects of concrete and rebar were reflected in the material model. To check the impact of voids and deterioration on the seismic performance of the containment building, iterative push-over analysis was performed on four cases of the analytical model with and without voids and deterioration. It was found that the effect of voids with a volume ratio of 0.6% on the seismic performance of the containment building was insignificant. The effect of strength reduction and cross-sectional area loss of reinforcement due to deterioration and the impact of strength increase of concrete due to long-term hardening offset each other, resulting in a slight increase in the lateral resistance of the containment building. To determine the limit state that adequately represents the seismic performance of the containment building considering voids and deterioration, the Ogaki shear strength equation, ASCE 43-05 low shear wall allowable lateral displacement ratio, and JEAC 4601 shear strain limit were compared and examined with the analytically derived failure point (ultimate point) in this study.

Research on mechanism of gas leakage in microchannels of steel containment vessels for nuclear power plants

  • Min He;Yueyao Chen;Zhen Wu;Gangling Hou;Jialong Wang;Zhuangfei Li;Yuzhu Wang;Hanze Li
    • Nuclear Engineering and Technology
    • /
    • 제56권8호
    • /
    • pp.3030-3042
    • /
    • 2024
  • Steel containment vessels for nuclear power plants can experience gas leakage due to minute defects such as cracks, corrosion, and aging, leading to gas leakage. A gas leakage model for microchannels is established to elucidate the mechanism underlying gas leakage within microchannels caused by these defects, specifically addressing the issue of unidirectional gas flow. Computational Fluid Dynamics (CFD) and the UK R6 method are employed to calculate the gas leakage rate within microchannels. Furthermore, the characteristics of gas flow within microchannels are explored, including the factors affecting the gas leakage rate. Validation of the calculation results is verified experimentally. The results indicate that the gas mass flow rate exhibits a linear decrease with decreasing internal pressure and a non-linear decline as temperature increases. Additionally, the gas mass flow rate demonstrates a negative correlation with the microchannel length but a positive association to its hydraulic diameter. The primary influencing factors on gas leakage rates are hierarchically ranked as follows: pressure difference, microchannel cross-sectional area, temperature, microchannel length, and microchannel hydraulic diameter.

Application of the machine learning technique for the development of a condensation heat transfer model for a passive containment cooling system

  • Lee, Dong Hyun;Yoo, Jee Min;Kim, Hui Yung;Hong, Dong Jin;Yun, Byong Jo;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2297-2310
    • /
    • 2022
  • A condensation heat transfer model is essential to accurately predict the performance of the passive containment cooling system (PCCS) during an accident in an advanced light water reactor. However, most of existing models tend to predict condensation heat transfer very well for a specific range of thermal-hydraulic conditions. In this study, a new correlation for condensation heat transfer coefficient (HTC) is presented using machine learning technique. To secure sufficient training data, a large number of pseudo data were produced by using ten existing condensation models. Then, a neural network model was developed, consisting of a fully connected layer and a convolutional neural network (CNN) algorithm, DenseNet. Based on the hold-out cross-validation, the neural network was trained and validated against the pseudo data. Thereafter, it was evaluated using the experimental data, which were not used for training. The machine learning model predicted better results than the existing models. It was also confirmed through a parametric study that the machine learning model presents continuous and physical HTCs for various thermal-hydraulic conditions. By reflecting the effects of individual variables obtained from the parametric analysis, a new correlation was proposed. It yielded better results for almost all experimental conditions than the ten existing models.

원전 격납 건물의 실시간 모니터링을 위한 강건한 최적 센서배치 연구 (A Study on Robust Optimal Sensor Placement for Real-time Monitoring of Containment Buildings in Nuclear Power Plants)

  • 이찬우;김유진;정형조
    • 한국전산구조공학회논문집
    • /
    • 제36권3호
    • /
    • pp.155-163
    • /
    • 2023
  • 원전 구조물의 실시간 모니터링 기술이 요구되고 있지만, 현재 운영 중인 지진 감시계통으로는 동특성 추출 등 시스템 식별이 제한된다. 전역적인 거동 데이터 및 동특성 추출을 위해서는 다수의 센서를 최적 배치하여야 한다. 최적 센서배치 연구는 많이 진행되어 왔지만 주로 토목, 기계 구조물이 대상이었으며 원전 구조물 대상으로 수행된 연구는 없었다. 원전 구조물은 미미한 신호대잡음비에도 강건한 신호를 획득하여야 하며, 모드 기여도가 저차 모드에 집중되어 있어 모드별 잡음 영향을 고려해야 하는 등 구조물 특성을 고려해야 한다. 이에 본 연구에서는 잡음에 대한 강건도와 모드별 영향을 평가할 수 있는 최적 센서배치 방법론을 제시하였다. 활용한 지표로서 auto MAC(Modal Assurance Criterion), cross MAC, 노드별 모드형상 분포를 분석하였으며, 잡음에 대한 강건도 평가의 적합성을 수치해석으로 검증하였다.

음압격리병실에서의 병실 문의 개폐속도에 따른 실간 압력변동 및 공기교환량에 대한 해석적 연구 (A Numerical Study on Pressure Fluctuation and Air Exchange Volume of Door Opening and Closing Speeds in Negative Pressure Isolation Room)

  • 김준영;홍진관
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권1호
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: In this study, through the comparison of the pressure fluctuation and air exchange volume in negative isolation room according to the type of the door and door opening/closing speeds, which is one of the main factors causing the cross contamination of the negative pressure isolation room, establishes standard operating procedures to prevent cross contamination in high risk infectious diseases and isolation room design. Methods: In this study, the air flow each of the room is analyzed using ANASYS CFX CODE for flow analysis. In addition, the grid configuration of the door is constructed by applying Immersed Solid Methods. Results: The pressure fluctuation due to the opening and closing of the hinged door was very large when the moment of the hinged door opened and closed. Especially, at the moment when the door is closed, a pressure reversal phenomenon occurs in which the pressure in the isolation room is larger than the pressure in the anteroom. On the other hand, the pressure fluctuation due to the opening and closing of the sliding door appeared only when the door was closed, but the pressure reversal phenomenon not occurred at the moment when the sliding door was closed, unlike the hinged door. As the opening and closing speed of the hinged door increases, the air exchange volume is increased. However, as the opening and closing speed of the sliding door is decreased, the air exchange volume is increased. Implications: According to the results of this study, it can be concluded that the pressure fluctuation due to the opening and closing of the hinged door is greater than the pressure fluctuation due to the opening and closing of the sliding door. In addition, it can be confirmed that the pressure reversal phenomenon, which may cause to reduce the containment effect in negative pressure isolation room, is caused by the closing of the hinged door. Therefore, it is recommended to install a sliding door to maintain a stable differential pressure in the negative isolation room. Also, as the opening and closing speed of the hinged door is slower and the opening and closing speed of the sliding door is faster, the possibility of cross contamination of the room can be reduced. It is therefore necessary to establish standard operating procedures for negative isolation room for door opening and closing speeds.

전단변형과 시간변화 이동자기력을 고려한 레일의 강제진동모델링 (Forced Vibration Modeling of Rail Considering Shear Deformation and Moving Magnetic Load)

  • 김준수;김성종;이혁;하성규;이영현
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1547-1557
    • /
    • 2013
  • 시간변화 이동자기력이 작용하는 레일의 변형을 티모센코 보 이론(Timoshenko beam theory)로 가정하였으며, 보의 진동특성에 영향을 미치는 탄성체기초의 감쇠효과 및 강성을 고려하였다. 푸리에 급수와 수치해석을 이용해 강제진동모델의 동적응답과 임계속도를 구하였다. 레일의 진동모델을 유한요소 해석 및 오일러 보 이론(Euler beam theory)과 비교 검증하였다. 강제진동모델을 이용하여 레일의 영구변형을 예측하였으며, 실험결과 레일표면의 영구변형 및 마모를 확인하였다. 보의 설계변수인 레일의 형상, 재료, 탄성체 기초의 감쇠효과 및 강성이 레일의 임계속도 및 레일의 처짐, 축 방향 응력, 전단 응력에 미치는 영향에 대한 매개변수적 연구를 진행하였으며, 보의 설계방향을 얻을 수 있었다.

Effect of physically contained greenhouse covered by fine mesh on pollen dispersal in maize

  • Watanabe, Shin;Kamada, Hiroshi;Ezura, Hiroshi
    • 한국식물생명공학회:학술대회논문집
    • /
    • 한국식물생명공학회 2005년도 추계학술대회 및 한일 식물생명공학 심포지엄
    • /
    • pp.367-370
    • /
    • 2005
  • The risk from genetically modified (GM) plants results from the possibility of gene contamination producing adverse effects on biological diversity by introducing herbicide or insect resistance into related plants or weeds (NAS 2002). The concern about the leakage of genes from GM plants into the environment has primarily focused on pollen that could be wind-borne for long distances. During the period of fisk assessment in Japan, physical containment is applied as a measure of reducing gene flow via the dispersal of pollen from GM plants into the surrounding environment In this study, we tried to estimate the effect of physically contained greenhouse covered by 1-mm fine mesh to reduce pollen dispersal by researching cross pollination rate between non-GM yellow maize in a greenhouse and silver maize outside the greenhouse.

  • PDF

도심항공교통(UAM) 운영을 위한 횡적 회랑 규격 실증 연구 (An Empirical Study on Establishing the Cross-track Corridor Dimension for UAM Operations)

  • 김도현;이경한;장효석;이승준
    • 한국항행학회논문지
    • /
    • 제28권1호
    • /
    • pp.21-26
    • /
    • 2024
  • 도심항공교통(UAM; urban air mobility)은 교통 혼잡이 증가하는 도시 지역에서 교통수단의 대안으로 주목받고 있다. 사람 중심의 서비스인 기존 항공교통업무 방법으로는 복잡한 UAM 운용환경을 관리하기는 어려울 것으로 판단된다. 따라서 UAM 항공교통관리 (UATM; UAM traffic management)를 위한 첨단 정보처리 기반 교통관리시스템이 필요하다. 체계적인 UATM 환경 구축을 위해서는 공역관리가 필수적이다. 특히 UAM 항공기가 안전하게 운항할 수 있는 배타적 회랑을 구축하면 최저비행고도 규정을 위반하지 않고도 UAM 항공기를 운항할 수 있는 기회를 제공할 수 있다. 본 연구에서는 UAM 운용을 위한 회랑의 횡단규격을 설정하기 위해 UAM과 유사한 규모의 헬리콥터를 이용하여 실증분석을 수행하였다. 연구 결과는 UAM 회랑 설계 시 지침으로 활용되기를 기대한다.

DEVELOPMENT OF AN AMPHIBIOUS ROBOT FOR VISUAL INSPECTION OF APR1400 NPP IRWST STRAINER ASSEMBLY

  • Jang, You Hyun;Kim, Jong Seog
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.439-446
    • /
    • 2014
  • An amphibious inspection robot system (hereafter AIROS) is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST) strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of installing sole cameras was a new approach for the exact and stable position control on the IRWST strainer, unlike a traditional robot for underwater facility inspection. The developed robot will be practically used to enhance the efficiency and reliability of the inspection of nuclear power plant components.

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction

  • Sun, Wenying;Du, Ying;Li, Xingku;Du, Bo
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권3호
    • /
    • pp.459-468
    • /
    • 2020
  • This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The results showed that the RT-PSR assay effectively detected all 8 HCV strains, and no false positives were found among the 7 non-HCV strains. The detection limit of our RT-PSR assay is comparable to the real-time RT-PCR, but is more sensitive than the RT-LAMP. The established RT-PSR assay was further evaluated for detection of HCV in clinical blood samples, and the resulting 80.25% detection rate demonstrated better or similar effectiveness compared to the RT-LAMP (79.63%) and real-time RT-PCR (80.25%). Overall, the results showed that the RT-PSR assay offers high specificity and sensitivity for HCV detection with great potential for screening HCV in clinical blood samples.