• Title/Summary/Keyword: Cross - Validation

Search Result 1,017, Processing Time 0.03 seconds

Monitoring, collecting, and validating data of inland wetland survey based on citizen science methodology

  • Inae Yeo;Kwangjin Cho;Yeonsu Chu;Pyoungbeom Kim;Sangwook Han
    • Journal of Ecology and Environment
    • /
    • v.48 no.3
    • /
    • pp.395-404
    • /
    • 2024
  • Background: In this study, citizen scientists gathered survey data by monitoring inland wetlands, recognized as carbon sinks, and verified the accuracy of the data for incorporation into ecosystem management policies. Results: In October 2022, citizen scientists conducted surveys on three taxonomical groups (plants, mammals, terrestrial insects) in three wetland protection areas. After capturing photographs with location information, these images were uploaded to a national ecological information bank (EcoBank) managed in Korea. The information collected by citizen scientists underwent cross-validation through two expert methods, involving ecology field experts. First, experts conducted a survey of invasive alien plants in the designated areas and compared their findings with those of citizen scientists. The choice of survey locations by citizen scientists was influenced by their proximity to their residences. Second, an expert scrutinized the accuracy of species names collected and uploaded to EcoBank by citizen scientists, presenting their findings. The classification accuracy for species names was 98.8% for vegetation (n = 83), 21.6% for terrestrial insects (n = 21), and 66.7% for mammals (n = 8). These results indicate that citizen scientists may lack detailed classification ability at the species level. Conclusions: Moving forward, it will be imperative to offer diverse forms of education to strengthen the capabilities of the citizen scientists, including sharing wetland survey results to enhance expertise in species identification, creating and distributing educational materials, and providing on-site education through professional surveyors.

Prediction of Key Variables Affecting NBA Playoffs Advancement: Focusing on 3 Points and Turnover Features (미국 프로농구(NBA)의 플레이오프 진출에 영향을 미치는 주요 변수 예측: 3점과 턴오버 속성을 중심으로)

  • An, Sehwan;Kim, Youngmin
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.1
    • /
    • pp.263-286
    • /
    • 2022
  • This study acquires NBA statistical information for a total of 32 years from 1990 to 2022 using web crawling, observes variables of interest through exploratory data analysis, and generates related derived variables. Unused variables were removed through a purification process on the input data, and correlation analysis, t-test, and ANOVA were performed on the remaining variables. For the variable of interest, the difference in the mean between the groups that advanced to the playoffs and did not advance to the playoffs was tested, and then to compensate for this, the average difference between the three groups (higher/middle/lower) based on ranking was reconfirmed. Of the input data, only this year's season data was used as a test set, and 5-fold cross-validation was performed by dividing the training set and the validation set for model training. The overfitting problem was solved by comparing the cross-validation result and the final analysis result using the test set to confirm that there was no difference in the performance matrix. Because the quality level of the raw data is high and the statistical assumptions are satisfied, most of the models showed good results despite the small data set. This study not only predicts NBA game results or classifies whether or not to advance to the playoffs using machine learning, but also examines whether the variables of interest are included in the major variables with high importance by understanding the importance of input attribute. Through the visualization of SHAP value, it was possible to overcome the limitation that could not be interpreted only with the result of feature importance, and to compensate for the lack of consistency in the importance calculation in the process of entering/removing variables. It was found that a number of variables related to three points and errors classified as subjects of interest in this study were included in the major variables affecting advancing to the playoffs in the NBA. Although this study is similar in that it includes topics such as match results, playoffs, and championship predictions, which have been dealt with in the existing sports data analysis field, and comparatively analyzed several machine learning models for analysis, there is a difference in that the interest features are set in advance and statistically verified, so that it is compared with the machine learning analysis result. Also, it was differentiated from existing studies by presenting explanatory visualization results using SHAP, one of the XAI models.

Development of Precast Concrete Method for Eco-Pillar Debris Barrier with Hollow Cross-Section (중공트랙형 단면의 프리캐스트 에코필라 사방댐 공법개발)

  • Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.542-552
    • /
    • 2018
  • In this paper, the precast method of a concrete eco-pillar debris barrier was proposed to improve the construct ability and economic efficiency. The performance was validated by experimental and structural analysis. The steel debris barrier has a high construction cost and causes environmental damage with corrosion. The construction of a concrete eco-pillar debris barrier has been increased recently. On the other hand, there are no design standards regarding debris barriers in Korea, and debris barriers are being designed by the experience and sense of engineers. Therefore, in this study, a method to determine the design external forces was proposed and the design was performed by applying a hollow cross-section to the debris barrier. In addition, three types of connection methods of a concrete cantilever column with the maximum bending moment acts were proposed, and validation of the performance of each type was performed with a real-scale experiment. The experimental results showed that the type with loop reinforcement had the highest rigidity and the type with anchorage performance exceeded the maximum bending moment according to the ultimate load. In the manufacturing procedure of mock-up debris barriers, the type with an anchorage-bar was found to have superior construct ability.

Ordinary kriging approach to predicting long-term particulate matter concentrations in seven major Korean cities

  • Kim, Sun-Young;Yi, Seon-Ju;Eum, Young Seob;Choi, Hae-Jin;Shin, Hyesop;Ryou, Hyoung Gon;Kim, Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.12.1-12.8
    • /
    • 2014
  • Objectives Cohort studies of associations between air pollution and health have used exposure prediction approaches to estimate individual-level concentrations. A common prediction method used in Korean cohort studies is ordinary kriging. In this study, performance of ordinary kriging models for long-term particulate matter less than or equal to $10{\mu}m$ in diameter ($PM_{10}$) concentrations in seven major Korean cities was investigated with a focus on spatial prediction ability. Methods We obtained hourly $PM_{10}$ data for 2010 at 226 urban-ambient monitoring sites in South Korea and computed annual average $PM_{10}$ concentrations at each site. Given the annual averages, we developed ordinary kriging prediction models for each of the seven major cities and for the entire country by using an exponential covariance reference model and a maximum likelihood estimation method. For model evaluation, cross-validation was performed and mean square error and R-squared ($R^2$) statistics were computed. Results Mean annual average $PM_{10}$ concentrations in the seven major cities ranged between 45.5 and $66.0{\mu}g/m^3$ (standard deviation=2.40 and $9.51{\mu}g/m^3$, respectively). Cross-validated $R^2$ values in Seoul and Busan were 0.31 and 0.23, respectively, whereas the other five cities had $R^2$ values of zero. The national model produced a higher cross-validated $R^2$ (0.36) than those for the city-specific models. Conclusions In general, the ordinary kriging models performed poorly for the seven major cities and the entire country of South Korea, but the model performance was better in the national model. To improve model performance, future studies should examine different prediction approaches that incorporate $PM_{10}$ source characteristics.

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.

An Analysis on the Stage-Discharge Relation Curve with the Temporal Variation of the River Bed -at Indogyo Station of the Han River- (하상(河床) 경년변화(經年變化)에 따른 수위(水位)-유량(流量) 관계곡선(關係曲線)의 해석(解析) -한강(漢江) 인도교지점(人道橋地點)을 중심(中心)으로-)

  • Cheong, Heung Soo;Lee, Won Hwan;Lee, Jae Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.61-71
    • /
    • 1988
  • The stage-discharge relation curve(rating curve) is the basic formula in hydrologic analysis. It plays an important role in converting to the discharge from available flood water level data including the daily mean stage. However, the river induces a cross section change at the gauging station because of the composed material of the river bed and three processes of the stream flow; i.e., erosion, transportation, and sedimentation. Rating curve has to be revised according to the temporal variation of the river bed due to the those factors. In this study, the basic rating curve is developed with respect to the current river bed to convert the existing rating curves and also to seize the hydraulic and geometric characteristics for the temporal variation of the river bed, relationships among the basic rating curve and the existing rating curves, water level, cross sectional area, and flow velocity are analyzed. Indogyo station, which is not only the key station of the Han river but also greatly changed the river bed after completion of the Han river development plan during the year 1983 to 1986, was chosen for the study. In this study, the river bed is assumed in a dynamic equilibrium condition. The basic rating curve is developed using hydrologic data of the physical year of 1987. For a given discharge, relationships for conversion of previous data, stage and velocity, the current one are formulated. To verify the usefulness of the relationships, stage-cross sectional area and stage velocity formula are also derived. Both hydrologic method using continuity equation and statistical method by the rating curve are compared and checked, then the validation of the both are positively shown.

  • PDF

Psychometric Validation of the Malaysian Chinese Version of the EORTC QLQ-C30 in Colorectal Cancer Patients

  • Magaji, Bello Arkilla;Moy, Foong Ming;Roslani, April Camilla;Law, Chee Wei;Sagap, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8107-8112
    • /
    • 2016
  • Background and Aims: Colorectal cancer is the second most frequent cancer in Malaysia. We aimed to assess the validity and reliability of the Malaysian Chinese version of European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire core (QLQ-C30) in patients with colorectal cancer. Materials and Methods: Translated versions of the QLQ-C30 were obtained from the EORTC. A cross sectional study design was used to obtain data from patients receiving treatment at two teaching hospitals in Kuala Lumpur, Malaysia. The Malaysian Chinese version of QLQ-C30 was self-administered in 96 patients while the Karnofsky Performance Scales (KPS) was generated by attending surgeons. Statistical analysis included reliability, convergent, discriminate validity, and known-groups comparisons. Statistical significance was based on p value ${\leq}0.05$. Results: The internal consistencies of the Malaysian Chinese version were acceptable [Cronbach's alpha (${\alpha}{\geq}0.70$)] in the global health status/overall quality of life (GHS/QOL), functioning scales except cognitive scale (${\alpha}{\leq}0.32$) in all levels of analysis, and social/family functioning scale (${\alpha}=0.63$) in patients without a stoma. All questionnaire items fulfilled the criteria for convergent and discriminant validity except question number 5, with correlation with role (r = 0.62) and social/family (r = 0.41) functioning higher than with physical functioning scales (r = 0.34). The test-retest coefficients in the GHS/QOL, functioning scales and in most of the symptoms scales were moderate to high (r = 0.58 to 1.00). Patients with a stoma reported statistically significant lower physical functioning (p=0.015), social/family functioning (p=0.013), and higher constipation (p=0.010) and financial difficulty (p=0.037) compared to patients without stoma. There was no significant difference between patients with high and low KPS scores. Conclusions: Malaysian Chinese version of the QLQ-C30 is a valid and reliable measure of HRQOL in patients with colorectal cancer.

Analysis and Comparison of Stream Discharge Measurements in Jeju Island Using Various Recent Monitoring Techniques (다양한 첨단 유량 계측기기를 활용한 제주도 하천 유출 비교 분석)

  • Yang, Sung-Kee;Kim, Dong-Su;Jung, Woo-Yul;Yu, Kwon-Kyu
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.783-788
    • /
    • 2011
  • Different from the main land of South Korea, Jeju Island has been in difficulties for measuring discharge. Due to high infiltration rate, most of streams in Jeju Island are usually in the dried state except six streams with the steady base flow, and the unique geological characteristics such as steep slope and short traveling distance of runoff have forced rainfall runoff usually to occur during very short period of time like one or two days. While discharge observations in Jeju Island have been conducted only for 16 sites with fixed electromagnetic surface velocimetry, effective analysis and validation of observed discharge data and operation of the monitoring sites still have been limited due to very few professions to maintain such jobs. This research is sponsored by Ministry of Land, Transport and Maritime Affairs to build water cycle monitoring and management system of Jeju Island. Specifically, the research focuses on optimizing discharge measurement techniques adjusted for Jeju Island, expanding the monitoring sites, and validating the existing discharge data. First of all, we attempted to conduct discharge measurements in streams with steady base flow, by utilizing various recent discharge monitoring techniques, such as ADCP, LSPIV, Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry. ADCP has been known to be the most accurate in terms of discharge measurement compared with other techniques, thus that the discharge measurement taken by ADCP could be used as a benchmark data for validation of others. However, there are still concerns of using ADCP in flood seasons; thereby LSPIV would be able to be applied for replacing ADCP in such flooded situation in the stream. In addition, sort of practical approaches such as Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry would also be validated, which usually measure velocity in the designated parts of stream and assume the measured velocity to be representative for whole cross-section or profile at any specified location. The result of the comparison and analysis will be used for correcting existing discharge measurement by Electromagnetic Wave Surface Velocimetry and finding the most optimized discharge techniques in the future.

Bioequivalence of Two Nilvadipine Tablet (닐바디핀 정제에 대한 생물학적 동등성 평가)

  • 김종국;이사원;최한곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The bioequivalence of two nilvadipine products was evaluated in 16 normal male volunteers (age 22-32 yr, body weight 57-80 kg) following sidle oral dose. Test product was Overca $l_{R}$ tablet (Choong-Wae Pharm. Corp., Korea) and reference product was Nivadi $l_{R}$ tablet (Hyundai Pharm. Corp., Korea). Both products contain 4 mg of nilvadipine. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of nilvadipine was accomplished using a validated capillary column GC with electron-capture detection. As a result of the assay validation, the quantiflcation of nilvadipine in human plasma by this technique was possible down to 0.5 ng/ml using 1 ml of plasma. Absolute overall recovery from five replicate analyses of nilvadipine-spiked sample were 88.4$\pm$ 10.24% (mean$\pm$ 5.D.) for human plasma of 10 ng/ml. The coefficients of variation (C.V.) were less than 20% and the actual concentration of nilvadipine measured by GC ranged from 80 to 99% in all plasma. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve from time zero to 8 hr (AUCo-$_{8 hr}$) (22.8$\pm$5.90 vs 22.2$\pm$6.10 ng . hr/ml), maximum plasma concentration ( $C_{max}$) (10.0$\pm$2.85 vs 9.3$\pm$3.28 ng/ml) and time to reach maximum plasma concentration ( $T_{max}$) (1.2$\pm$0.31 vs 1.3 $\pm$0.47 hr). The differences of mean AU $Co_{8hr}$ $C_{max}$, and $T_{max}$ between the two products (2.25, 7.65, and 10.30%, respectively) were less than 20%. The power (1-$\beta$) and treaeent difference (7) for AU $Co_{8hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for Tmax was under 0.8, Tm\ulcorner of the two products was not significantly different from each other (p>0. 05). These results suggest that the bioavailability of Overeat tablet is not significantly different from that of Nivadil tablet. Therefore, two products are bioequivalent based on the current results.sults.lts.lts.lts.

  • PDF

Automatic Detection Approach of Ship using RADARSAT-1 Synthetic Aperture Radar

  • Yang, Chan-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.2
    • /
    • pp.163-168
    • /
    • 2008
  • Ship detection from satellite remote sensing is a crucial application for global monitoring for the purpose of protecting the marine environment and ensuring marine security. It permits to monitor sea traffic including fisheries, and to associate ships with oil discharge. An automatic ship detection approach for RADARSAT Fine Synthetic Aperture Radar (SAR) image is described and assessed using in situ ship validation information collected during field experiments conducted on August 6, 2004. Ship detection algorithms developed here consist of five stages: calibration, land masking, prescreening, point positioning, and discrimination. The fine image was acquired of Ulsan Port, located in southeast Korea, and during the acquisition, wind speeds between 0 m/s and 0.4 m/s were reported. The detection approach is applied to anchoring ships in the anchorage area of the port and its results are compared with validation data based on Vessel Traffic Service (VTS) radar. Our analysis for anchoring ships, above 68 m in length (LOA), indicates a 100% ship detection rate for the RADARSAT single beam mode. It is shown that the ship detection performance of SAR for smaller ships like barge could be higher than the land-based radar. The proposed method is also applied to estimate the ship's dimensions of length and breadth from SAR radar cross section(RCS), but those values were comparatively higher than the actual sizes because of layover and shadow effects of SAR.

  • PDF