• Title/Summary/Keyword: Cros

Search Result 24, Processing Time 0.027 seconds

The Genetic Analysis of Quantitative Characters in the Silkworm by Diallel Cross of Four Inbred Lines Differing in Silk Yield (견생산력이 다른 계통간의 Diallel Cross에 의한 누에 양적 형질의 유전분석)

  • 손기욱;유강선
    • Journal of Sericultural and Entomological Science
    • /
    • v.29 no.2
    • /
    • pp.7-14
    • /
    • 1987
  • Extensive studies were undertaken to analyze the genetic basis of economically important quantitative characters in the silkworm by diallel crosses of four inbred lines differing widely in silk yielding ability. Some differences between the reciprocal corsses were detected in cocoon weight, cocoon shell weight, cocoon filament length and cocoon filament weight in case the parental lines were greatly differenent each other in silk yielding ability. The general combining ability (GCA) varied with the inbred lines and M242, a Chieese sexlimited larval marking variety showed high GCA value in the economic characters, such as cocoon yield, cocoon weight, cocoon filament length and weight, and raw silk percentage. The highest heterosis effect, about 13% to 14% was seen in cocoon and raw silk yield and it was low in cocoon reelability and raw silk percentage with less than 1%. It is advisable to improve highly heritable quantitative characters such as larval duration, cocoon shell weight, cocoon filament length and raw silk percentage by means of selection, and to select single crosses with high heterosis effect for cocoon weight and cocoon yield which show overdominance. Genetic correlation should be considered when more than two characters are targets for improvement and selecting high cocoon shell weight is effective to breed high silk yielding varieties. It is difficult to improve cocoon reelability because of low heritability (0.11) and its negative correlation with cocoon-silk quality.

  • PDF

Why is 90% Confidence Interval Used When Confidence Interval Approach is Used for Testing Equivalence? (동등성 시험을 신뢰구간을 사용하여 검정하는 경우 왜 신뢰도 90%인 신뢰구간을 사용하는가?)

  • Kang, Seung-Ho
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.5
    • /
    • pp.867-873
    • /
    • 2008
  • It is a convention to use 5% significance level when a statistical test is employed for clinical data. But when a confidence interval is used for testing equivalence, 90% confidence interval has often been used. When $1-{\alpha}$ confidence interval is used for hypothesis testing, its significance level is often ${\alpha}$. So it makes a confusion that the significance level is 10% if 90% confidence interval is employed for testing equivalence. In this paper I will clarify this issue by reviewing relevant papers and conducting simulation studies. I hope that it will be beneficial to statisticians in pharmaceutical companies, CROs, university hospitals.

TMP station을 이용한 UBMS(Unbalanced magnetron sputtering) 시스템 개발

  • Gang, Chung-Hyeon;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.70-70
    • /
    • 2017
  • TSV(through silicon via)는 긴 종횡비를 갖는 패턴에 Cu, Ta, Ti을 높은 conformality를 갖도록 증착하는 공정이다. Magnetron cathode의 자석 배열 설계는 target 물질 종류에 따라서 multitrack, water drop type등이 있으며 target과 substrate 사이의 공간에 플라즈마를 형성시켜서 기판에 이온 입사량을 늘린 후 기판 바이어스를 이용하여 이온 충돌, re-sputtering을 통한 재증착 과정을 통해 치밀한 금속 박막을 연속적으로 형성할 수 있도록 하는 것이 목적이다. 또한 sputter가 사용되고 있는 분야에 효율을 증대시키고, 증착되는 막의 품질향상을 위해 UBMS를 사용하고 있으며, 산업에 사용되어 지는 300 mm wafer용 시스템은 제작비가 약 10억 원 정도 소요되며 다양한 테스트를 진행하기 위해선 많은 비용이 소요된다. 따라서 비용과 소요시간을 줄여 다양한 테스트를 위해 소규모 플라즈마 시스템을 설계하게 되었다. 61 l/sec 터보 분자 펌프와 다이아프램 펌프를 기초로한 TMP station에 2.75 인치 CF flange가 장착된 6 way cross를 main 챔버로 활용하고, 작은 size의 unbalanced magnetron cathode를 제작, 장착한 다음 6 way cross 주변에 전자석을 적절히 배치하여 300 mm wafer system에서와 동일한 물리적 현상을 테스트 할 수 있도록 하였다. Fig1. (a) UBMS system의 사진을 나타내었고, (b)에는 6 way cross 내부에 발생된 플라즈마의 형상을 나타내었다. 전원 장치는 Advanced Energy사의 MDX-1.5K DC power supply를 사용하였고, 방전 전압 - 전류 관계의 가스 압력에 따른 plasma 현상과 magnetron 배율에 따른 plasma 현상 그리고 전자석에 의한 영향을 주로 관찰 하였다.

  • PDF

Study on the Latest Trends of u-Health and Relations of Medical Technologist

  • Sung, Hyun-Ho;An, Yong-Ho;Lee, Dong-Beom;Kim, Sang-Won;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.4
    • /
    • pp.178-183
    • /
    • 2012
  • We investigated the latest trend of u-Health and relations with clinical technologist. Since 2000, Korea has become an aging society. Korea will become an aged society by 2018, and it is expected to enter the ultra-high aged society by 2026. Increase in over 65 years population means that the desire of medical service and care demand for the elderly is greatly required. In addition, many predicted Korean national health insurance would falter financially. Medical suppression policies and regulations are also amended continuously. U-Health based on the IT industry and development of related technologies and industries contains the variety concepts of telemedicine, telehealth, e-health, u-healthcare and POCT. Especially, the use of POCT supplied quick clinical examination is extending steadily in medical center and hospital, which will generate the field friction between nurses and medical technologists. In the transition situation from provider-centric service to consumer-driven health care system, this study recommended the principal role and correspondence of clinical laboratory workers and offered information about changes in healthcare market and the basic concept of expert system, measurement and the diagnosis principle to clinical technicians throughout the investigation of the recent research and government policy trends.

  • PDF

Oral Mucosal Adhesive Tablets of Omeprazole (오메프라졸 구강점막 부착정제에 관한 연구)

  • Jung, Jae-Hee;Choi, Han-Gon;Park, Sun-Joo;Ryu, Jei-Man;Yoon, Sung-June
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.2
    • /
    • pp.133-137
    • /
    • 1997
  • Buccal absorption test of omeprazole in human was performed to determine the permeability of the drug molecule through oral mucous membrane. Oral mucosal adhesive tablets of omeprazole were prepared by compressing the omeprazole with a mixture of sodium alginate and hydroxypropylmethyl cellulose (HPMC) as bioadhesive polymers, magnesium oxide (MgO) as a stabilizer and sodium carboxymethyl cellulose (Na CMC) or cros-carmellose sodium (Ac-Di-Sol) as disintegrants. The bioadhesive force, stability in saliva and release characteristics of the tablets were evaluated. Omeprazole was absorbed about 23% in 15 min through human buccal mucous membrane. Furthermore, omeprazole was stable in saliva for more than 8 hrs when MgO was added to the tablet as the amount of 2.5 fold of omeprazole. The release rate of omeprazole was increased with increasing the amount of sodium alginate in the tablet. From these results, it is suggested that tablets composed of [omeprazole/HPMC/sodium alginate/MgO/Ac-Di-Sol and/or Na CMC (20/6/24/50/10) (mg/tablet)] are potential candidate for buccal drug delivery system.

  • PDF

Design of Frequency Selective Surface Based Artificial Magnetic Conductor Using the Particle Swarm Optimization (PSO를 이용한 주파수 선택 구조 기반 인공 자기 도체 설계)

  • Hong, Ic-Pyo;Lee, Kyung-Won;Yook, Jong-Gwan;Cho, Chang-Min;Chun, Hueng-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.610-616
    • /
    • 2010
  • In this paper, particle swarm optimization(PSO) is applied for the design of frequency selective surface based artificial magnetic conductor. An equivalent circuit model for this artificial magnetic conductor(AMC) with Jerusalem Cross arrays was derived and then PSO was applied for obtaining the optimized geometrical parameters with desired resonant frequency. The resonant frequency and the reflection phase characteristics from the optimization were compared to the results from commercial software for verifying the validity of this paper. The procedure presented in this paper can be applied to design the AMC with different frequency selective surface and also can be used for the design of microwave circuits like the AMC ground planes.

fMRI of Visual and Motor Stimuli : Difference of Total Activation Depends on Stimulation Paradigm (시각과 운동의 뇌기능영상 : 자극에 따른 총활성화의 차이)

  • 정순철;송인찬;장기현;유병기;문치웅;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • Purpose : To investigate the difference of total activation in visual area, motor area, and cerebellum according to the stimulation paradigm. Materials and Methods : Functional MR imaging was performed in 5 healthy volunteers with visual and motor activity using EPI technique. LED and Checker-Board stimulation were performed for visual activity. Thumb motion and Finger Tapping were performed for motor and cerebellum activity. Stimulus timing was 60sec. off, 120sec. on, 60sec. off. Data processing was carried out by using the cross-correlation method for each pixel. Each pixel was then selected and assumed activated if the correlation coefficient was equal or larger than a threshold value. Time course data was obtained by calculating the total activation which was defined as the number of activated pixel x averaged pixel intensity. Results : In the case of visual activity with LED stimulation, we found increased total activity of more than 100% compared with Checker-Board stimulation. In the case of motor area and cerebellum with Finger tapping stimulation, we found increased total activity of more than 10% and 150%, respectively compared with Thumb motion stimulation.

  • PDF

Design and fabrication of current limiting InP Gunn diode for W-band waveguide FTO (W-band 도파관 FTO 적용을 위한 전류제한 InP Gunn diode 설계 및 제작)

  • Ko, Dong-Sik;Kwak, No-Seong;Kim, Young-Jin;Heo, Jun-Woo;Ko, Pil-Seok;Kim, Sam-Dong;Park, Hyun-Chang;Rhee, Jin-Koo;Chun, Young-Hoon;Lee, Seok-Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.45-54
    • /
    • 2014
  • In this paper, We have designed and fabricated 20 InP Gunn diodes using a current limiting epitaxial structure by MINT's optimized fabrication processes. We have also packaged the fabricated InP Gunn diodes using our optimized packaging method, and then designed and fabricated a W-band waveguide FTO to measure characteristics of the packaged InP Gunn diodes. The packaged InP Gunn diode have a ceramic ring, a Au plated stud and a lid, and a Maltese cross. The fabricated InP Gunn diodes have good RF characteristics such as high output powers (11.8~17 dBm) and limiting low currents (less than 400 mA) between 92.9 and 94.78 GHz.

Field Study of Effects of Night Shifts on Cognitive Performance, Salivary Melatonin, and Sleep

  • Kazemi, Reza;Motamedzade, Majid;Golmohammadi, Rostam;Mokarami, Hamidreza;Hemmatjo, Rasoul;Heidarimoghadam, Rashid
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.203-209
    • /
    • 2018
  • Background: Night shift work is associated with many problems such as sleep deprivation, sleepiness, decreased cognitive performance, increased human errors, and fatigue. This study set out to measure cognitive performance, melatonin rhythms, and sleep after different consecutive night shifts (7 vs. 4) among control room operators (CORs). Methods: The participants included 60 CORs with a mean age of 30.2 years (standard deviation, 2.0) from a petrochemical complex located in Southern Iran. Cognitive performance was assessed using the n-back task and continuous performance test. To evaluate melatonin, saliva was collected and tested by enzyme-linked immunosorbent assay. To assess sleep and sleepiness, the Pittsburgh Sleep Quality Index and Karolinska Sleepiness Scale were used, respectively. Results: Individuals who worked 7 consecutive night shifts had a significantly better cognitive performance and sleep quality than those who worked 4 consecutive night shifts. However, salivary melatonin profile and sleepiness trend were not affected by shift type. Conclusion: The main duty of CORs working night shifts at the studied industry included managing safety-critical processes through complex displays; a responsibility that demands good cognitive performance and alertness. It is suggested that an appropriate number of consecutive night shifts in a rotating shift system should be planned with the ultimate aim of improving CROs performance/alertness and enhancing safety.

Incorporation of RAPD linkage Map Into RFLP Map in Glycine max (L, ) Merr (콩의 RAPD 연관지도를 RFLP 연관지도와 합병)

  • Choi, In-Soo;Kim, Yong-Chul
    • Journal of Life Science
    • /
    • v.13 no.3
    • /
    • pp.280-290
    • /
    • 2003
  • The incorporation of RAPD markers into the previous classical and RFLP genetic linkage maps will facilitate the generation of a detailed genetic map by compensating for the lack of one type of marker in the region of interest. The objective of this paper was to present features we observed when we associated RAPD map from an intraspecific cross of a Glycine max$\times$G. max, 'Essex'$\times$PI 437654 with the public RFLP map developed from an interspecific cross of G. max$\times$G. soja. Among 27 linkage groups of RAPD map, eight linkage groups contained probe/enzyme combination RFLP markers, which allowed us the incorporation of RAPD markers into the public RFLP map. Map position rearrangement was observed. In incorporating L.G.C-3 into the public RFLP linkage group a1 and a2, both pSAC3 and pA136 region, and pA170/EcoRV and pB170/HindIII region were in opposite order, respectively. And, pk400 was localized 1.8 cM from pA96-1 and 8.4 cM from pB172 in the public RFLP map, but was localized 9.9 cM from i locus and 18.9 cM from pA85 in our study. A noticeable expansion of the map distances in the intraspecific cross of Essex and PI 437654 was also observed. Map distance between probes pA890 and pK493 in L.G.C-1 was 48.6 cM, but it was only 13.3 cM in the public RFLP map. The distances from the probe pB32-2 to pA670 and from pA670 to pA668 in L.G. C-2 were 50.9 cM and 31.7 cM, but they were 35.9 cM and 13.5 cM in the public RFLP map. The detection of duplicate loci from the same probe that were mapped on the same or/and different linkage group was another feature we observed.