• Title/Summary/Keyword: Critical electric field

Search Result 174, Processing Time 0.026 seconds

Buckling treatment of piezoelectric functionally graded graphene platelets micro plates

  • Abbaspour, Fatemeh;Arvin, Hadi
    • Steel and Composite Structures
    • /
    • v.38 no.3
    • /
    • pp.337-353
    • /
    • 2021
  • Micro-electro-mechanical systems (MEMS) are widely employed in sensors, biomedical devices, optic sectors, and micro-accelerometers. New reinforcement materials such as carbon nanotubes as well as graphene platelets provide stiffer structures with controllable mechanical specifications by changing the graphene platelet features. This paper deals with buckling analyses of functionally graded graphene platelets micro plates with two piezoelectric layers subjected to external applied voltage. Governing equations are based on Kirchhoff plate theory assumptions beside the modified couple stress theory to incorporate the micro scale influences. A uniform temperature change and external electric field are regarded along the micro plate thickness. Moreover, an external in-plane mechanical load is uniformly distributed along the micro plate edges. The Hamilton's principle is employed to extract the governing equations. The material properties of each composite layer reinforced with graphene platelets of the considered micro plate are evaluated by the Halpin-Tsai micromechanical model. The governing equations are solved by the Navier's approach for the case of simply-supported boundary condition. The effects of the external applied voltage, the material length scale parameter, the thickness of the piezoelectric layers, the side, the length and the weight fraction of the graphene platelets as well as the graphene platelets distribution pattern on the critical buckling temperature change and on the critical buckling in-plane load are investigated. The outcomes illustrate the reduction of the thermal buckling strength independent of the graphene platelets distribution pattern while meanwhile the mechanical buckling strength is promoted. Furthermore, a negative voltage, -50 Volt, strengthens the micro plate stability against the thermal buckling occurrence about 9% while a positive voltage, 50 Volt, decreases the critical buckling load about 9% independent of the graphene platelet distribution pattern.

신속한 3차원 전자탐사 모델링

  • Jo, In-Gi;Kim, Ha-Rim
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The integral equation method is a powerful tool for electromagnetic numerical modeling. But the difficulty of this technique is the size of their linear equations, which demands excessive memory and calculation time to invert. This limitation of the integral equation method becomes critical in inverse problem. To overcome this limitation, a lot of approximation and series methods, such as conventional Born, modifed Born and extended Born, were developed. But all the methods need volume integration of Green tensor, which is very time consuming. In electromagnetic theory, Green tensor rapidly decreases as the distance between source and field cell increases. Therefore, the source cell which are far away from the field cell does not make an effect on the electric field of the field cell. Consequently, by ignoring the effect of Green tensor due to far away source cells, computing time for electromagnetic numerical modeling can be reduced dramatically. Comparisons of this new method against a full integral equation, extended Born approximation and series code show that the method is accurate enough much less time consuming.

  • PDF

Effect of $\textrm{Ca}^{2+}$ Concentration on Electric Activation of In Vitro Matured Oocytes of Korean Native Cattle ($\textrm{Ca}^{2+}$ 씨오투 농도가 체외성숙 유래 한우 난자의 전기적 활성화에 미치는 영향)

  • 송길영;이은송;이병천;황우석
    • Journal of Embryo Transfer
    • /
    • v.11 no.3
    • /
    • pp.259-269
    • /
    • 1996
  • The present study was undertaken to examine the critical effect of $Ca^2$+ concentration on electrostimulation and post-electrostimulation media for electric activation of in vitro matured oocytes of Korean Native Cattle. Oocytes collected from slaughterhouse ovaries were matured in TCM 199 containing FSH, estradiol-17$\beta$ and FBS with granulosa cell monolayer for 24 hours and denuded with hyaluronidase. And then cumulus-free oocytes were submitted to a DC field of 1.0 kV/cm for 60 $\mu$sec in electroporation media(0.28 M mannito' and PBS) with different $Ca^2$+ concentations (0.00, 0.05, 0.10 and 0.15 mM). Stimulated oocytes were stained and examined for pronuclear formation after incuhation in SOF for 12 hours. The rates of pronuclear formation in hovine oocytes electrically stimulated in 0.28 M mannitol with 0.05, 0.10 and 0.15 mM $Ca^2$+(60.3, 82.2 and 75.0%) were significantly higher than without $Ca^2$+(6.3%) at 12 hours after an electric pulse(p<0.005). The activation rates of Korean Native Cattle oocytes stimulated in PBS supplemented with 0.05, 0.10 and 0.15 mM $Ca^2$+(71.0, 75.8 and 75.4%) were significantly higher than without $Ca^2$+(23.5%) after post-stimulation incubation(p<0.005). After incubation of oocytes in SOF with and without $Ca^2$+ following electric stimulation in 0.28 M mannitol with 0.10 mM $Ca^2$+, the rates of pronuclear formation of bovine oocytes in $Ca^2$+-free SOF(85.7%) was significantly higher than in SOF with 1.71 mM $Ca^2$+(62.5%, p<0.05). When oocytes were stimulated in two electrostimulation media supplemented with $Ca^2$+ and incubated in $Ca^2$+-free SOF, there were no significant differences in the rates of pronuclear formation hetween 0.28 M mannitol and PBS. These results indicate that a single electric pulse could induce activation of Korea Native Cattle oocytes in 0.28 M mannitol and PBS supplemented with $Ca^2$+. Furthermore, to improve the activation rates, it was hetter that stimulated oocytes were incubated in $Ca^2$+-free SOF after electric stimulation than in SOF with $Ca^2$+.

  • PDF

Study on the 2G High Temperature Superconducting Coil for Large Scale Superconducting Magnetic Energy Storage Systems (대용량 에너지 저장장치용 2세대 고온 초전도 코일의 특성해석)

  • Lee, Ji-Young;Lee, Seyeon;Kim, Yungil;Park, Sang Ho;Choi, Kyeongdal;Lee, Ji-Kwang;Kim, Woo-Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.157-162
    • /
    • 2015
  • Large scale superconducting magnetic energy storage (SMES) system requires very high magnetic energy density in its superconducting coils to enhance the energy capacity and efficiency of the system. The recent high temperature superconducting (HTS) conductors, so called 2G conductors, show very good performance under very high magnetic field so that they seem to be perfect materials for the large scale SMES coils. A general shape of the coil system with the 2G HTS conductor has been a tor oid, because the magnetic field applied perpendicularly to the surface of the 2G HTS conductor could be minimized in this shape of coil. However, a toroid coil requires a 3-dimensional computation to acquire the characteristics of its critical current density - magnetic field relations which needs very complicated numerical calculation, very high computer specification, and long calculation time. In this paper, we suggested an analytic and statistical calculation method to acquire the maximum magnetic flux density applied perpendicularly to the surface of the 2G HTS conductor and the stored energy in the toroid coil system. Although the result with this method includes some errors but we could reduce these errors within 5 percent to get a reasonable estimation of the important parameters for design process of the HTS toroid coil system. As a result, the calculation time by the suggested method could be reduced to 0.1 percent of that by the 3-dimensional numerical calculation.

Characterization Analyses for Direct Current Tumor Ablation (직류 전류 이용 종양세포치료의 특성 연구)

  • Yang, T.K.;Kim, J.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.307-312
    • /
    • 2011
  • As a technique for removing cancerous tumors from normal tissue, radio-frequency electromagnetic waves were employed to heating target cells up to the critical temperature, which kills the cancerous cells. However, its use in treating tumors in soft organs is limited by inconvenient factors, which are use of high-currents and long time operation. In this work, the feasibility of the localized heating by inserting four conducting electrodes with tiny direct current is investigated. The heat source is resulting from the electric field as known as resistive heating. We have investigated the temperature distribution as a function of applying DC voltages ranging from 10 V to 30 V with 10 V step. From the simulation results, the mushroom-like lesion shape by applying 20 V is generated by four electrodes within a few minutes, that is proper to the clinical application.

Design, Development and Analysis of Embedded Systems for Condition Monitoring of Rotating Machines using FFT Algorithm

  • Dessai, Sanket;Naaz, Zakiyaunnissa Alias Naziya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.428-432
    • /
    • 2014
  • Rotating machines are an integral part of large electrical power machinery in most of the industries. Any degradation or outages in the rotating electric machinery can result in significant losses in productivity. It is critical to monitor the equipment for any degradation's so that it can serve as an early warning for adequate maintenance activities and repair. Prior research and field studies have indicated that the rotating machines have a particular type of signal structure during the initial start-up transient. A machine performance can be studied based on the effect of degradation in signal parameters. In this paper a data-acquisition system and the FFT algorithm has been design and model using the MATLAB and Simulink. The implementation had been carried out on the TMS320 DSP Processor and various testing and verification of the machine performance had been carried out. The results show good agreement with expected results for both simulated and real-time data. The real-time data from AC water pumps which have rotating motors built-in were collected and analysed. The FFT algorithm provides frequency response and based on this frequency response performance of the machine had been measured.The FFT algorithm provides only approximation about the machine performances.

Electrical Properties of Conductive Copper Filler/Epoxy Resin Composites (전도성 구리충전제/에폭시수지 복합체의 전기적 특성)

  • Lee, Jung-Eun;Park, Young-Hee;Oh, Seung-Min;Lim, Duk-Jum;Oh, Dae-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.472-479
    • /
    • 2013
  • The conductive polymer composites recently became increasingly to many fields of industry due to their electrical properties. To understand these properties of composites, electrical properties were measured and were studied relatively. Electrical conductivity measurements showed percolation phenomena. Percolation theories are frequently applied to describe the insulator-to-conductor transitions in composites made of a conductive filler and an insulating matrix. It has been showed both experimentally and theoretically that the percolation threshold strongly depends on the aspect ratio of filler particles. The critical concentration of percolation formed is defined as the percolation threshold. This paper was to study epoxy resin filled with copper. The experiment was made with vehicle such as epoxy resin replenished with copper powder and the study about their practical use was performed in order to apply to electric and electronic industry as well as general field. The volume specific resistance of epoxy resin composites was 3.065~13.325 in using copper powder. The weight loss of conductive composites happened from $350^{\circ}C{\sim}470^{\circ}C$.

Effect of operating conditions of high voltage impulse on generation of hydroxyl radical (고전압 펄스의 수중인가 조건이 하이드록실 라디칼 생성에 미치는 영향)

  • Cho, Seung-Yeon;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.611-618
    • /
    • 2017
  • Recently, applications of high voltage impulse (hereafter HVI) technique to desalting, sludge solubilization and disinfection have gained great attention. However, information on how the operating condition of HVI changes the water qualities, particularly production of hydroxyl radical (${\cdot}OH$) is not sufficient yet. The aim of this study is to investigate the effect of operating conditions of the HVI on the generation of hydroxyl radical. Indirect quantification of hydroxyl radical using RNO which react with hydroxyl radical was used. The higher HVI voltage applied up to 15 kV, the more RNO decreased. However, 5 kV was not enough to produce hydroxyl radical, indicating there might be an critical voltage triggering hydroxyl radical generation. The concentration of RNO under the condition of high conductivity decreased more than those of the low conductivities. Moreover, the higher the air supplies to the HVI reactor, the greater RNO decreased. The conditions with high conductivity and/or air supply might encourage the corona discharge on the electrode surfaces, which can produce the hydroxyl radical more easily. The pH and conductivity of the sample water changed little during the course of HVI induction.

Free vibration and buckling analysis of elastically restrained FG-CNTRC sandwich annular nanoplates

  • Kolahdouzan, Farzad;Mosayyebi, Mohammad;Ghasemi, Faramarz Ashenai;Kolahchi, Reza;Panah, Seyed Rouhollah Mousavi
    • Advances in nano research
    • /
    • v.9 no.4
    • /
    • pp.237-250
    • /
    • 2020
  • An accurate plate theory for assessing sandwich structures is of interest in order to provide precise results. Hence, this paper develops Layer-Wise (LW) theory for reaching precise results in terms of buckling and vibration behavior of Functionally Graded Carbon Nanotube-Reinforced Composite (FG-CNTRC) annular nanoplates. Furthermore, for simulating the structure much more realistic, its edges are elastically restrained against in-plane and transverse displacement. The nano structure is integrated with piezoelectric layers. Four distributions of Single-Walled Carbon Nanotubes (SWCNTs) along the thickness direction of the core layer are investigated. The Differential Quadrature Method (DQM) is utilized to solve the motion equations of nano structure subjected to the electric field. The influence of various parameters is depicted on both critical buckling load and frequency of the structure. The accuracy of solution procedure is demonstrated by comparing results with classical edge conditions. The results ascertain that the effects of different distributions of CNTs and their volume fraction are significant on the behavior of the system. Furthermore, the amount of in-plane and transverse spring coefficients plays an important role in the buckling and vibration behavior of the nano-structure and optimization of nano-structure design.

A study of interfacial characteristics for $In_{0.1}Ga_{0.9}As/GaAs$ by photoreflectance measurement (Photoreflectance 측정에 의한 $In_{0.1}Ga_{0.9}As/GaAs$ 계면의 특성 조사)

  • 이철욱;김인수;손정식;김동렬;임재영;배인호
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.3
    • /
    • pp.263-266
    • /
    • 1997
  • We studied an interfacial characteristics of $In_{0.1}Ga_{0.9}As$/ GaAs by photoreflectance (PR) measurement at room temperature. With increasing thickness of epitaxial layer, Franz-Keldysh oscillation (FKO) periods of PR signals were decreased, and interfacial electric field was decreased. This can be explained by the increases of defects due to lattice mismatch near the heterointerface between InGaAs and GaAs. For the thickness of epitaxial layer thinner than the 300$\AA$, InGaAs epitazial layer closed to critical thickness and increased strain, and then the bandgap energy shifted high greatly.

  • PDF