• Title/Summary/Keyword: Critical Time

Search Result 4,800, Processing Time 0.031 seconds

A Study on Voltage Stability Improvement by the Efficient Network Reconfiguration Algorithm

  • Kim, Byung-Seop;Shin, Joong-Rin;Park, Jong-Bae;Shin, Yong-Hak
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.58-68
    • /
    • 2004
  • This paper presents an optimal routing algorithm (ORA) for maximizing voltage stability as well as for minimizing power loss in radial power systems. In the proposed ORA, a novel voltage stability index (VSI) for real-time assessment is newly introduced based on the conventional critical transmission path framework. In addition, the suggested algorithm can automatically detect the critical transmission paths resulting in voltage collapse when additional real or reactive loads are added. To implement an effective ORA, we have developed an improved branch exchange (IBE) method based on a loss calculation index and tie-branch power flow equations, which are suggested for real-time applications. The proposed algorithm has been tested with IEEE test systems as well as a large-scale power system in Korea to demonstrate its effectiveness and efficiency.

A Study on RCM Approach to Catenary System of Electric Railway (전기철도 가공전차선로의 신뢰성 기반 유지보수(RCM)에 관한 연구)

  • Youn, Eung-Kyu;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1457-1465
    • /
    • 2016
  • A RCM approach to maintenance of the catenary system of electric railway is proposed. The proposed RCM approach provides a maintenance-oriented FMECA procedure to derive critical failure modes by analyzing failure effects and a RCM decision logic tree to suggest optimal maintenance works for the derived failure modes. By applying the proposed RCM procedures to the catenary system of high speed railway, it is suggested that strand breaks of dropper and voltage equalizing wire, and trolly wire wear-out are the critical failure modes for whom maintenance works based on condition monitoring should be applied instead of conventional time-based preventive maintenance. It is also proposed by reliability analysis that replacement time of dropper can be reduced from 18 years to 10 years. These results show that the proposed RCM approach can optimize the maintenance procedures of catenary system.

Development of new cleaning technology using ionized water by electrolysis (전기분해 이온수를 이용한 세정기술 개발)

  • 변문기;백희원;조봉희;김영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.617-620
    • /
    • 1999
  • To reduce the consumption of chemicals and ultra pure water(UPW) in cleaning process used in device manufacturing, we proposed wet processes that use electrolytic ionized water(EIW), which is generated by electrolysis of a diluted electrolyte solution or UPW and systemically investicate the EIW\`s characteristics. EIW\`s pH values are increased in cathode chamber and decreased in anode chamber according to the electrolysis time and its varied ratio is reduced with time increasement. The variation of pH and ORP is increased accordin to the applied voltage until critical voltage. But more than that voltage, the variation is decreased because of ion\`s scattering effect. When electrolyte is added, the effects of electrolysis is increased because electrolyte acts as catalyst. But when the density of electrolyte is increased more than critical value, ion\`s flowage is obstructed and the effects of electrolysis is decreased.

  • PDF

EXPERIMENTAL STUDY OF CRITICAL HEAT FLUX WITH ALUMINA-WATER NANOFLUIDS IN DOWNWARD-FACING CHANNELS FOR IN-VESSEL RETENTION APPLICATIONS

  • Dewitt, G.;Mckrell, T.;Buongiorno, J.;Hu, L.W.;Park, R.J.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.335-346
    • /
    • 2013
  • The Critical Heat Flux (CHF) of water with dispersed alumina nanoparticles was measured for the geometry and flow conditions relevant to the In-Vessel Retention (IVR) situation which can occur during core melting sequences in certain advanced Light Water Reactors (LWRs). CHF measurements were conducted in a flow boiling loop featuring a test section designed to be thermal-hydraulically similar to the vessel/insulation gap in the Westinghouse AP1000 plant. The effects of orientation angle, pressure, mass flux, fluid type, boiling time, surface material, and surface state were investigated. Results for water-based nanofluids with alumina nanoparticles (0.001% by volume) on stainless steel surface indicate an average 70% CHF enhancement with a range of 17% to 108% depending on the specific flow conditions expected for IVR. Experiments also indicate that only about thirty minutes of boiling time (which drives nanoparticle deposition) are needed to obtain substantial CHF enhancement with nanofluids.

A CRL Distribution Scheme Minimizing the Time for CRL Processing of Vehicles on Vehicular Communications

  • Kim, Hyun-Gon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.73-80
    • /
    • 2018
  • Certification revocation list(CRL) is needed for excluding compromised, faulty, illegitimate vehicle nodes and preventing the use of compromised cryptographic materials in vehicular communications. It should be distributed to vehicles resource-efficiently and CRL computational load of vehicles should not impact on life-critical applications with delay sensitive nature such as the pre-crash sensing that affords under 50msec latency. However, in the existing scheme, when a vehicle receives CRL, the vehicle calculates linkage values from linkage seeds, which results in heavy computational load. This paper proposes, a new CRL distribution scheme is proposed, which minimizes the time for CRL processing of vehicles. In the proposed scheme, the linkage value calculation procedure is performed by road-side unit(RSU) instead of the vehicle, and then the extracted linkage values are relayed to the vehicle transparently. The simulation results show that the proposed scheme reduces the CRL computational load dramatically, which would minimize impact on life-critical applications' operations with low latency.

Onset of Buoyancy-Driven Convection in a Fluid-Saturated Porous Layer Bounded by Semi-infinite Coaxial Cylinders

  • Kim, Min Chan
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.723-729
    • /
    • 2019
  • A theoretical analysis was conducted of convective instability driven by buoyancy forces under transient temperature fields in an annular porous medium bounded by coaxial vertical cylinders. Darcy's law and Boussinesq approximation are used to explain the characteristics of fluid motion and linear stability theory is employed to predict the onset of buoyancy-driven motion. The linear stability equations are derived in a global domain, and then cast into in a self-similar domain. Using a spectral expansion method, the stability equations are reformed as a system of ordinary differential equations and solved analytically and numerically. The critical Darcy-Rayleigh number is founded as a function of the radius ratio. Also, the onset time and corresponding wavelength are obtained for the various cases. The critical time becomes smaller with increasing the Darcy-Rayleigh number and follows the asymptotic relation derived in the infinite horizontal porous layer.

Current Status of Respiratory Care in Korean Intensive Care Units (국내 중환자실내 호흡치료의 현황)

  • Park, So-Yeon;Kim, Tae-Hyung;Kim, Eun-Kyung;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.343-352
    • /
    • 2000
  • Backgrounds : Respiratory care for patients in intensive care units (ICUs) has been performed mainly by nurses in Korea. However, the current status of respiratory care in the Korea ICUs is not well known. Respiratory care and the methods of delivery in ICUs were surveyed. Method : A confidential questionnaire was distributed to the head nurses working the ICUs at 117 hospitals in Korea. One hundred hospitals returned the questionnaires, for a response rate of 85%. The hospitals were divided into three groups : Main university hospitals (MUH), university associated hospitals (UAH), and general hospitals (GH) Result : Eighteen units of 66 units in MUH and 35 units of 58 units in GH were organized as a general ICUs. The percentage of ICUs with full-time doctors was 47.1%. The nurses usually delivered respiratory care spending from 1 to 4 h during their 8 h of working time. Although the respondents felt that respiratory care should be delivered by trained respiratory therapists, these therapists were not found at the hospitals. Most of the units performed percussion, tracheal suctioning, and positional changes. However, vibration and IPPB were less frequently performed in GH. Among oxygen supply apparatus, venturi mask and T-piece were not frequently used in GH. GH applied a noninvasive ventilator mode less frequently than MUH and UAH. The percentage of Swan-Ganz catheter monitoring was only 21.4% in GH. Conclusion : Respiratory care for patients in the Korean ICUs was provided by nurses on the whole. In addition, there were many differences in the level of respiratory care according to the type of hospital. To overcome the current problems revealed, an effective in-hospital training program for the development of full-time respiratory care therapists should be established urgently in Korea.

  • PDF

Analysis of production performance and sensory evaluation for shucking oyster using pressure (압력으로 박신한 굴 생산성능과 관능평가 분석)

  • Ok-sam KIM;Eun-Bi MIN;Doo-jin HWANG;Geum-Bum YOO
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.35-43
    • /
    • 2023
  • Sensory evaluation of shucking pressure, pressure holding time, seeding method, difference in full shucking rate in the aquaculture area and shucking oyster was performed using an ultra-high pressure oyster shucking machine. The reaching time for each target pressure is 2.2-2.4 MPa/sec in the range of 180 MPa to 240 MPa. had a rate of pressure rise. There was a difference of 0.5-1.7℃ in the range of 24-27℃ in the seawater temperature before and after the pressure treatment inside the pressure vessel, but there was no specific increase or decrease in seawater temperature. When only the shucking pressure is increased without the pressure holding time, the critical shucking pressure at which the oyster shell is opened and the flesh is peeled in the range of 200 to 220 MPa. When the critical shucking pressure is reached, the oyster sample in the closed vessel is expected to be shucked by about 40%. If there is no pressure holding time when judged only by full shucking, an increase in pressure of about 1.5 MPa is required to further shuck 3% of the oyster population. The oyster samples cultivated in the south coast of Korea were subject to full shucking under the conditions of 220 MPa shucking pressure and two minutes (120 seconds) of pressure holding time, and the difference in the pressure of the oysters according to the oyster seeding method and the farming area was minute. Finally, the condition of 220 MPa of shucking pressure and three minutes of pressure holding time was the best at 1.52 when the result of the sensory evaluation performed manually was set to 1.0. Next was 1.4 under the conditions of 220 MPa of shucking pressure and one minute of pressure holding time (60 seconds), and 1.3 under the condition of 220 MPa and two minutes of pressure holding time (120 seconds). Therefore, it is considered that the most desirable shucking conditions, considering the efficiency and sensory evaluation results, are the conditions of 220 MPa shucking pressure and two to three minutes of pressure holding time.

Factors Influencing of Evidence based Practice Competency and Evidence based Practice Readiness in General Hospital Nurses (종합병원 간호사의 근거기반실무 준비도와 근거기반실무 역량의 영향 요인)

  • Ryu, Seang;Kim, Yun-Sook;Kim, Yun Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.5
    • /
    • pp.448-460
    • /
    • 2016
  • Purpose: The study was done to verify evidence-based practice (EBP) readiness and factors contributing to EBP competency in general hospital nurses. Methods: Participants were 219 nurses working in 7 general hospitals in G-city and J Province. Data were collected from May 12 to May 28, 2015 and analyzed using one-way ANOVA, Pearson's correlation and stepwise multiple regression. Results: Mean score for EBP competency was $3.89{\pm}0.83$, for critical thinking disposition, $3.35{\pm}0.36$, for EBP attitude, $3.53{\pm}0.66$, for beliefs about value of EBP, $3.42{\pm}0.56$, for ability in research performance, $2.86{\pm}0.57$, for time to devote to EBP, $2.57{\pm}0.69$ and for organization support for EBP, $3.36{\pm}0.46$. EBP competency was significantly correlated with critical thinking disposition (r=.37, p<.001), beliefs about value of EBP (r=.43, p<.001), ability in research performance (r=.44, p<.001), and time to devote to EBP(r=.33, p<.001). Factors influencing EBP competency in general hospital nurses were research performance (${\beta}=.29$, p<.001), beliefs about value of EBP (${\beta}=.24$, p<.001), critical thinking disposition (${\beta}=.15$, p=.014), recognition of EBP (${\beta}=-.18$, p=.002), which together explained 35% of total variance. Conclusion: Findings indicate that introduction and activation of EBP in general hospitals is essential and development of systematic training programs to strengthen critical thinking disposition and EBP competency are needed.

Self-control of high rise building L-shape in plan considering soil structure interaction

  • Farghaly, A.A.
    • Coupled systems mechanics
    • /
    • v.6 no.3
    • /
    • pp.229-249
    • /
    • 2017
  • A new technique to mitigate irregular buildings with soil structure interaction (SSI) effect subjected to critical seismic waves is presented. The L-shape in plan irregular building for various reasons was selected, subjected to seismic a load which is a big problem for structural design especially without separation gap. The L-shape in plan building with different dimensions was chosen to study, with different rectangularity ratios and various soil kinds, to show the effect of the irregular building on the seismic response. A 3D building subjected to critical earthquake was analyzed by structural analysis program (SAP2000) fixed and with SSI (three types of soils were analyzed, soft, medium and hard soils) to find their effect on top displacement, base shear, and base torsion. The straining actions were appointed and the treatment of the effect of irregular shape under critical earthquake was made by using tuned mass damper (TMD) with different configurations with SSI and without. The study improve the success of using TMDs to mitigate the effect of critical earthquake on irregular building for both cases of study as fixed base and raft foundation (SSI) with different TMDs parameters and configurations. Torsion occurs when the L-shape in plan building subjected to earthquake which may be caused harmful damage. TMDs parameters which give the most effective efficiency in the earthquake duration must be defined, that will mitigate these effects. The parameters of TMDs were studied with structure for different rectangularity ratios and soil types, with different TMD configurations. Nonlinear time history analysis is carried out by SAP2000 with El Centro earthquake wave. The numerical results of the parametric study help in understanding the seismic behavior of L-shape in plan building with TMDs mitigation system.