• 제목/요약/키워드: Critical Time

검색결과 4,800건 처리시간 0.027초

급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상 (Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation)

  • 이규성;정우영;정윤정;박주헌;신승수;황성철;박광주
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

Distance Functions to Detect Changes in Data Streams

  • Bud Ulziitugs;Lim, Jong-Tae
    • Journal of Information Processing Systems
    • /
    • 제2권1호
    • /
    • pp.44-47
    • /
    • 2006
  • One of the critical issues in a sensor network concerns the detection of changes in data streams. Recently presented change detection schemes primarily use a sliding window model to detect changes. In such a model, a distance function is used to compare two sliding windows. Therefore, the performance of the change detection scheme is greatly influenced by the distance function. With regard to sensor nodes, however, energy consumption constitutes a critical design concern because the change detection scheme is implemented in a sensor node, which is a small battery-powered device. In this paper, we present a comparative study of various distance functions in terms of execution time, energy consumption, and detecting accuracy through simulation of speech signal data. The simulation result demonstrates that the Euclidean distance function has the highest performance while consuming a low amount of power. We believe our work is the first attempt to undertake a comparative study of distance functions in terms of execution time, energy consumption, and accuracy detection.

FPGA 에 대한 지연시간 최적화 알고리듬 (Delay optimization algorithm on FPGAs)

  • 허창우;김남우
    • 한국정보통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.1259-1265
    • /
    • 2006
  • 본 논문에서는 고속 FPGA 설계를 위한 논리 수준의 조합회로 합성 알고리듬을 제안한다. 제안된 알고리듬은 회로의 지연시간을 줄이기 위해 critical path를 분할한다. 그리고 분할된 회로를 동시에 수행하는 구조를 갖는 회로를 생성한다. 본 커널 선택 알고리듬은 SUN UNIX 환경에서 C 언어로 구현되었다. 제안된 커널 선택 알고리듬은 기존의 FlowMap 지연시간 최적화 알고리듬과 결과를 비교하였다. 제안된 지연시간 최적화 알고리듬이 기존 알고리듬 에 비해 지연시간이 평균 33.3 % 감소된 회로를 생성함을 보였다.

지능형 자동차의 분산형 시스템을 위한 FlexRay 네트워크 시스템의 구현 (Implementation of FlexRay Network System for Distributed Systems of Intelligent Vehicle)

  • 하경남;이원석;이경창;이석
    • 제어로봇시스템학회논문지
    • /
    • 제13권10호
    • /
    • pp.933-939
    • /
    • 2007
  • Safety critical systems such as x-by-wire systems require in-vehicle network systems that can interconnect various sensors, actuators, and controllers. These networks need to have high data rate, deterministic operation, and fault tolerance. Recently, FlexRay protocol that is a time-triggered protocol has been introduced, and many automotive companies have been focusing on this protocol. This paper presents a design method of FlexRay network system and implementation of FlexRay-based motor control system.

전압다적해의 특성 및 유도전동기부하를 갖는 계통에 있어서의 전압안정 (Properties of Multiple Load Flow Solutions and Prevention of Voltage Collapse in System with Induction Motor Load)

  • Park, Jong-Keun
    • 대한전기학회논문지
    • /
    • 제34권1호
    • /
    • pp.19-28
    • /
    • 1985
  • As is well known, the power equations of the N-node system have 2N-1 voltage solutions at most. The vlotage solutions are characterized by the introduction of the mode concept in this paper. There are two mode voltages at one node. One is defined as the (+) mode voltage and the other is defined as the (-) mode one. In this paper, we show that the (-) mode voltage responds to the increase of the power condenser almost adversly to the response of the (+) one. We study how to prevent the voltage collapse in the system with the induction motor load. The critical values of the gain and the time constant in case of the continuous power condenser control, and of the unit power condenser and the closing time delay in case of the discontinuous control for the prevention of the voltage collapse, are calculated. The effect of the composition ratio of the impedance load to the induction moter load on the above critical values are also investigated.

  • PDF

Analysis of Several Digital Network Technologies for Hard Real-time Communications in Nuclear Plant

  • Song, Ki-Sang;No, Hee-Cheon;Kim, Dong-Hun;Koo, In-Soo
    • Nuclear Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.226-235
    • /
    • 1999
  • Applying digital network technology for advanced nuclear plant requires deterministic communication for tight safety requirements, timely and reliable data delivery for operation-critical and mission-critical characteristics of nuclear plant. Communication protocols, such as IEEE 802/4 Token Bus, IEEE 802/5 Token Ring, FDDI, and ARCnet, which have deterministic communication capability are partially applied to several nuclear power plants. Although digital communication technologies have many advantages, it is necessary to consider the noise immunity from electromagnetic interference (EMI), electrical interference, impulse noise, and heat noise before selecting specific digital network technology for nuclear plant. In this paper, we consider the token frame loss and data frame loss rate due to the link error event, frame size, and link data rate in different protocols, and evaluate the possibility of failure to meet the hard real-time requirement in nuclear plant.

  • PDF

An Analysis on Power Demand Reduction Effects of Demand Response Systems in the Smart Grid Environment in Korea

  • Won, Jong-Ryul;Song, Kyung-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1296-1304
    • /
    • 2013
  • This study performed an analysis on power demand reduction effects exhibited by demand response programs, which are advanced from traditional demand-side management programs, in the smart grid environment. The target demand response systems for the analysis included incentive-based load control systems (2 month-ahead demand control system, 1~5 days ahead demand control system, and demand bidding system), which are currently implemented in Korea, and price-based demand response systems (mainly critical peak pricing system or real-time pricing system, currently not implemented, but representative demand response systems). Firstly, the status of the above systems at home and abroad was briefly examined. Next, energy saving effects and peak demand reduction effects of implementing the critical peak or real-time pricing systems, which are price-based demand response systems, and the existing incentive-based load control systems were estimated.

New Method to Quantify the Operation Condition for Zone 3 Impedance Relays during Low-Frequency Power Swings

  • Li, Shenghu
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.29-35
    • /
    • 2008
  • With long time setting, zone 3 impedance relays are considered insensitive to power swings, and their operation condition during power swings is seldom analyzed. Instead of ti me-consuming simulation to the swing loci, their operation condition is directly quantified by polynominal functions in this paper to find the critical swing angle and frequency for relay operation under different relay settings and system parameters. It is found: (1) the swing loci are more densely populated inside than outside of the protection region, which corresponds to long residence time and possible relay operations; (2) the relays may be sensitive to load encroac hments and stable power swings with different relay settings and system parameters; (3) the critical swing frequency may be in the range of low-frequency power swings.

안정동력학에 의한 가변수요 통행배정모형 (A Variable Demand Traffic Assignment Model Based on Stable Dynamics)

  • 박구현
    • 한국경영과학회지
    • /
    • 제34권1호
    • /
    • pp.61-83
    • /
    • 2009
  • This study developed a variable demand traffic assignment model by stable dynamics. Stable dynamics, suggested by Nesterov and do Palma[19], is a new model which describes and provides a stable state of congestion in urban transportation networks. In comparison with the user equilibrium model, which is based on the arc travel time function in analyzing transportation networks, stable dynamics requires few parameters and is coincident with intuitions and observations on congestion. It is therefore expected to be a useful analysis tool for transportation planners. In this study, we generalize the stable dynamics into the model with variable demands. We suggest a three stage optimization model. In the first stage, we introduce critical travel times and dummy links and determine variable demands and link flows by applying an optimization problem to an extended network with the dummy links. Then we determine link travel times and path flows in the following stages. We present a numerical example of the application of the model to a given network.

Allocation Model of Container Yard for A TC Optimal Operation in Automated Container Terminal

  • Kim, Hwan-Seong;Nguyen, DuyAnh
    • 한국항해항만학회지
    • /
    • 제32권9호
    • /
    • pp.737-742
    • /
    • 2008
  • In this paper, we deal with an allocation model of vertical type container yard for minimizing the total ATC (Automated Transfer Crane) working time and the equivalence of ATC working load in each block on automated container terminal. Firstly, a layout of automated container terminal yard is shown The characteristic of equipment which work in the terminal and its basic assumption are given Next, an allocation model which concerns with minimizing the total working time and the equivalence of working load is proposed for effectiveness of ATC working in automated container terminal. Also, a weight values on critical function are suggested to adjust the critical values by evaluating the obtained allocation plan. For ATC allocation algorithm, we suggest a simple repeat algorithm for on-line terminal operation.