• Title/Summary/Keyword: Critical Frequency

Search Result 1,459, Processing Time 0.035 seconds

Frequency characteristics and sensitivity analysis of a size-dependent laminated nanoshell

  • Dai, Zuocai;Jiang, Zhiyong;Zhang, Liang;Habibi, Mostafa
    • Advances in nano research
    • /
    • v.10 no.2
    • /
    • pp.175-189
    • /
    • 2021
  • In this article, frequency characteristics, and sensitivity analysis of a size-dependent laminated composite cylindrical nanoshell under bi-directional thermal loading using Nonlocal Strain-stress Gradient Theory (NSGT) are presented. The governing equations of the laminated composite cylindrical nanoshell in thermal environment are developed using Hamilton's principle. The thermodynamic equations of the laminated cylindrical nanoshell are obtained using First-order Shear Deformation Theory (FSDT) and Fourier-expansion based Generalized Differential Quadrature element Method (FGDQM) is implemented to solve these equations and obtain natural frequency and critical temperature of the presented model. The novelty of the current study is to consider the effects of bi-directional temperature loading and sensitivity parameter on the critical temperature and frequency characteristics of the laminated composite nanostructure. Apart from semi-numerical solution, a finite element model was presented using the finite element package to simulate the response of the laminated cylindrical shell. The results created from finite element simulation illustrates a close agreement with the semi-numerical method results. Finally, the influences of temperature difference, ply angle, length scale and nonlocal parameters on the critical temperature, sensitivity, and frequency of the laminated composite nanostructure are investigated, in details.

The Oscillation Characteristics of a Magneticfluid Plug in Curved Tube (곡관내 자성유체 PLUG의 진동특성)

  • Chun, U.H.;Lee, H.N.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.46-57
    • /
    • 1995
  • The aim of the present study is to provide fundamental informations for the development of magneticfluid actuator. To achieve the aim, oscillation characteristics of the magneticfluid plug are investigated by experiment for the various length and position of the magneticfluid plug and the frequency of magnetic field. The oscillation characteristics are obtained. Amplitude, natural frequency, phase shift and damping ratio, are compared with theoretical values. From the study, the following conclusive remarks can be made. The experimental equation for the magnetic field is obtained. The critical magneticfluid length exists and its value is about 70mm. The range of the damping ratio and fluid loss coefficient obtained by experiment are 0.1~0.2 and 30~100, respectively. Comparison between experimental and theoretical results of oscillation characteristics shows good agreement in the high frequency range. Meanwhile, in the low frequency range, there appears little discrepancies(5% in the frequency and amplitude and 10% in phase difference and damping ratio) with each other.

  • PDF

Resonant Frequency Modulation of High Temperature Superconductors Subjected to Optical Pulse Energy and Temperature (광학 펄스 에너지와 온도 변화에 의한 고온 초전도체의 공명 진동수 변조)

  • Cho, Shin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1061-1067
    • /
    • 2005
  • The resonant frequency modulation of $YBa_2Cu_3O_{7-x}$ meander lines has been investigated as functions of optical pulse energy and temperature by using a network analyzer. The frequency-domain measurements are performed by controlling both the resonant frequency and the frequency width. The meander lines, configured in a microstrip geometry, are illuminated by optical pulses from an actively mode-locked Nd:YAG laser. The variation of the resonant frequency shows a quadratic dependence on the reduced optical pulse energy $P/P_c$, where $P_c$ is defined as the critical optical pulse energy at which resonance signal has disappeared. As for the dependence on temperature, the results are in good agreement with the previously reported data.

Clinical Features according to the Frequency of Acute Exacerbation in COPD

  • Lee, Seung-Jun;Lee, Seung-Hun;Kim, Yu-Eun;Cho, Yu-Ji;Jeong, Yi-Yeong;Kim, Ho-Cheol;Kim, Jin-Hyun;You, Jin-Jong;Yoon, Chul-Ho;Lee, Jong-Deog;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.4
    • /
    • pp.367-373
    • /
    • 2012
  • Background: Chronic obstructive pulmonary disease (COPD) is now regarded as a heterogenous disease, with variable phenotypes. Acute exacerbation of COPD is a major event that alters the natural course of disease. The frequency of COPD exacerbation is variable among patients. We analyzed clinical features, according to the frequency of acute exacerbation in COPD. Methods: Sixty patients, who visited Gyeongsang National University Hospital from March 2010 to October 2010, were enrolled. Patients were divided into two groups, according to their frequency of acute exacerbation. Frequent exacerbator is defined as the patient who has two or more exacerbation per one year. We reviewed patients' medical records and investigated modified Medical Research Council (MMRC) dyspnea scale, smoking history and frequency of acute exacerbation. We also conducted pulmonary function test and 6-minute walking test, calculated body mass index, degree of airway obstruction and dyspnea and exercise capacity (BODE) index and measured CD146 cells in the peripheral blood. Results: The number of frequent exacerbators and infrequent exacerbators was 20 and 40, respectively. The frequent exacerbator group had more severe airway obstruction (forced expiratory volume in one second [$FEV_1$], 45% vs. 65.3%, p=0.001; $FEV_1$/forced vital capacity, 44.3% vs. 50.5%, p=0.046). MMRC dyspnea scale and BODE index were significantly higher in the frequent exacerbator group (1.8 vs. 1.1, p=0.016; 3.9 vs. 2.1, p=0.014, respectively). The fraction of CD146 cells significantly increased in the frequent exacerbator group (2.0 vs. 1.0, p<0.001). Conclusion: Frequent exacerbator had more severe airway obstruction and higher symptom score and BODE index. However, circulating endothelial cells measured by CD146 needed to be confirmed in the future.

Vibration and stability of embedded cylindrical shell conveying fluid mixed by nanoparticles subjected to harmonic temperature distribution

  • Shokravi, Maryam;Jalili, Nader
    • Wind and Structures
    • /
    • v.25 no.4
    • /
    • pp.381-395
    • /
    • 2017
  • Nonlinear vibration and instability of cylindrical shell conveying fluid-nanoparticles mixture flow are studied in this article. The surrounding elastic medium is modeled by Pasternak foundation. Mixture rule is used for obtaining the effective viscosity and density of the fluid-nanoparticles mixture flow. The material properties of the elastic medium and cylindrical shell are assumed temperature-dependent. Employing first order shear deformation theory (FSDT), the motion equations are derived using energy method and Hamilton's principal. Differential quadrature method (DQM) is used for obtaining the frequency and critical fluid velocity. The effects of different parameters such as volume percent of nanoparticles, boundary conditions, geometrical parameters of cylindrical shell, temperature change, elastic foundation and fluid velocity are shown on the frequency and critical fluid velocity of the structure. Results show that with increasing volume percent of nanoparticles in the fluid, the frequency and critical fluid velocity will be increases.

Vibration and instability of nanocomposite pipes conveying fluid mixed by nanoparticles resting on viscoelastic foundation

  • Natanzi, Abolfazl Jafari;Jafari, Gholamreza Soleimani;Kolahchi, Reza
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.569-582
    • /
    • 2018
  • In this study, nonlinear vibration and stability of a polymeric pipe reinforced by single-walled carbon naotubes (SWCNTs) conveying fluid-nanoparticles mixture flow is investigated. The Characteristics of the equivalent composite are determined using Mori-Tanaka model considering agglomeration effects. The surrounding elastic medium is simulated by orthotropic visco-Pasternak medium. Employing nonlinear strains-displacements, stress-strain energy method the governing equations were derived using Hamilton's principal. Differential quadrature method (DQM) is used for obtaining the frequency and critical fluid velocity. The influence of volume percent of SWCNTs, agglomeration, geometrical parameters of pipe, viscoelastic foundation and fluid velocity are shown on the frequency and critical fluid velocity of pipe. Results showed the increasing volume percent of SWCNTs leads to higher frequency and critical fluid velocity.

Dynamic Snapping and Frequency Characteristics of 3-Free-Nodes Spatial Truss Under the Periodic Loads (주기 하중을 받는 3-자유절점 공간 트러스의 동적 불안정 현상과 주파수 특성)

  • Shon, Sudeok;Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.149-158
    • /
    • 2020
  • The governing equation for a dome-type shallow spatial truss subjected to a transverse load is expressed in the form of the Duffing equation, and it can be derived by considering geometrical non-linearity. When this model under constant load exceeds the critical level, unstable behavior is appeared. This phenomenon changes sensitively as the number of free-nodes increases or depends on the imperfection of the system. When the load is a periodic function, more complex behavior and low critical levels can be expected. Thus, the dynamic unstable behavior and the change in the critical point of the 3-free-nodes space truss system were analyzed in this work. The 4-th order Runge-Kutta method was used in the system analysis, while the change in the frequency domain was analyzed through FFT. The sinusoidal wave and the beating wave were utilized as the periodic load function. This unstable situation was observed by the case when all nodes had same load vector as well as by the case that the load vector had slight difference. The results showed the critical buckling level of the periodic load was lower than that of the constant load. The value is greatly influenced by the period of the load, while a lower critical point was observed when it was closer to the natural frequency in the case of a linear system. The beating wave, which is attributed to the interference of the two frequencies, exhibits slightly more behavior than the sinusoidal wave. And the changing of critical level could be observed even with slight changes in the load vector.

Fluidelastic instability of a curved tube array in single phase cross flow

  • Kang-Hee Lee;Heung-Seok Kang;Du-Ho Hong;Jong-In Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1118-1124
    • /
    • 2023
  • Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6×9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability.

Computation of Critical Length for Linear Grounding Electrodes (직선형 접지전극의 임계길이의 산정)

  • Kim, Ki-Bok;Lee, Bok-Hee;Joe, Jeong-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.67-74
    • /
    • 2009
  • For the surge currents like lightning currents containing high frequency components and the abnormal currents having high frequencies which cause the EMI(Electromagnetic interference) problems for the electronic devices and communication instruments, the linear grounding electrodes have the significantly composite impedance characteristics which are dependent on the frequency of the applied current. The impedance of a grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode having the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertically and horizontally-buried grounding electrodes are calculated by using the distributed parameter circuit model. The propriety of the simulations has been confirmed by comparing the simulated results with the measured results.

Vibration Characteristics and Analysis of the Critical Crack Length for a Fracture in the Last Stage Blade of a Low Pressure Steam Turbine (균열을 내재한 저압터빈 최종단 블레이드의 진동 특성 및 파괴 임계균열길이 해석)

  • Youn, Hee-Chul;Woo, Chang-Ki;Rhee, Zhang-Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.386-392
    • /
    • 2016
  • The sizes of last stage blades (LSB) in a low-pressure steam turbine have been getting larger for the development of high-capacity power plants. They are also larger than other blades in the same system. As a result, crack propagation in an LSB is caused by the large centrifugal force, low natural frequency, and repeated turbine startups. In this study, the critical crack length for a fracture and vibration characteristics, in accordance with crack propagation, were analyzed using a finite element method to calculate the stress intensity factor (SIF) and the natural frequency that was affected by the stress-stiffening effect. It was calculated that the frequency of the third and fifth modes passed the excited harmonic resonance (5X and 10X) and the observed calculated critical crack length matched that of the real fractured surface.