• Title/Summary/Keyword: Crack Measurement

Search Result 434, Processing Time 0.034 seconds

Simulation of Cracking Behavior Induced by Drying Shrinkage in Fiber Reinforced Concrete Using Irregular Lattice Model (무작위 격자 모델을 이용한 파이버 보강 콘크리트의 건조수축 균열 거동 해석)

  • Kim, Kunhwi;Park, Jong Min;Bolander, John E.;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.353-359
    • /
    • 2010
  • Cementitious matrix based composites are vulnerable to the drying shrinkage crack during the curing process. In this study, the drying shrinkage induced fracture behavior of the fiber reinforced concrete is simulated and the effects of the fiber reinforcement conditions on the fracture characteristics are analysed. The numerical model is composed of conduit elements and rigid-body-spring elements on the identical irregular lattice topology, where the drying shrinkage is presented by the coupling of nonmechanical-mechanical behaviors handled by those respective element types. Semi-discrete fiber elements are applied within the rigid-body-spring network to model the fiber reinforcement. The shrinkage parameters are calibrated through the KS F 2424 free drying shrinkage test simulation and comparison of the time-shrinkage strain curves. Next, the KS F 2595 restrained drying shrinkage test is simulated for various fiber volume fractions and the numerical model is verified by comparison of the crack initiating time with the previous experimental results. In addition, the drying shrinkage cracking phenomenon is analysed with change in the length and the surface shape of the fibers, the measurement of the maximum crack width in the numerical experiment indicates the judgement of the crack controlling effect.

Microcrack Development in the Pocheon Granite due to Cyclic Loading (피로하중에 의한 포천화강암의 미세균열 발달특성)

  • 장보안;김영화;김재동;이찬구
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.275-284
    • /
    • 1998
  • Deformation behavior and microcrack development due to uniaxial compressive cyclic loading in the Pocheon granite were investigated using the ultrasonic velocity measurements and the differential strain analysis(DSA). Most microcracks were developed along the direction parallel to the loading axis. Microcracks developed at the early stage of cyclic loading were formed by propagation of pre-existing cracks. Ultrasonic velocity measurement, DSA and measurement of permanent deformation are good tools to represent microcrack development in rock. Since results from each method are slightly different, microcrack development should be interpreted from all three methods. The magnitude of microcracks developed at the early stage of cyclic loading under 80% loading level is twice compared with those under 70% loading level. The highest volumetric crack strain is about 3000, indicating that the Pocheon granite will fail with 0.3% occupation of microcrack in volume.

  • PDF

J-R Curve Characterization by Load Ratio Analysis and Unloading Compliance Method for SA508 C-3 steel (SA508-3재의 제하컴플라이언스법과 하중비해석을 이용한 파괴저항곡선 평가)

  • 임만배;차귀준;윤한기;안원기
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.65-75
    • /
    • 1998
  • The fracture resistance curve is one of most important and design techniques employed in nuclear pressure vessel structures. This study is to evaluate the J-R curve characteristics for the SA508C-3 by the unloading compliance method and load rato analysis. The effect of strain aging for the exponential correlation of the J-R curve in this metal are investigated at room temperature, 20$0^{\circ}C$ and 30$0^{\circ}C$. The load ratio analysis method can evaluate the J-R curve by using the simple tension load-displacement curve only without the repeat of the unloading and loading. Therefore, the analysis by the proposed load ratio method has a merit, in comparison with the unloading compliance method, which can measure the crack length without the precision measurement equipment.

  • PDF

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

Residual Stress Measurement for Circular Disk Using Fraction Mechanics Approach (파괴역학을 이용한 원판형 부재의 잔류응력 측정)

  • 강기주;최성렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1218-1226
    • /
    • 1993
  • A method, so called 'successive cracking method,' for measuring residual stresses in a circular disk is proposed. In this method residual stresses are evaluated using a fracture mechanics approach, that is, the strains measured at a point on a edge of the disk as a crack is introduced and extended from the edge are used to deduce the residual stress distribution which existed in the uncracked disk. Through finite element analysis and comparative experiments with generally used sectioning method, the successive cracking method is shown to be valid, simple and effective to measure 2-dimensional residual stress distribution in a circular disk.

A Study on the Strain Analysis of Cracked Plate by Electronic Speckle Pattern Interferometry (전자처리 Speckle Pattern 간섭법에 의한 균열평판의 Strain 해석에 관한 연구)

  • 김경석;양승필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1382-1390
    • /
    • 1995
  • Electronic Speckle Pattern Interferometry (ESPI) with a CW laser, a video system and an image processor was utilized to measure the in-plane displacement. Unlike traditional strain gauges or Moire method. ESPI method measure the in-plane displacement on real time with out any surface preparation on surface attachment. The specimen has a crack of 10*0.1 mm in the middle of plate and strain gauge was also attached on that surface to compare with ESPI method. This study reveled the ESPI method to measure the displacement and distribution of strain in the specimen. It was shown in tensile tests that the measurement by ESPI method was comparable with strain gauge.

Improvement in Probability of Detection for Leakage Magnetic Flux Methods (누설자속탐상법의 결함검출능력 향상에 관한 연구)

  • Lee, Jin-Yi
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.13-18
    • /
    • 2004
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. Leakage magnetic flux near the crack on the specimen could be amplified by 3-dimensional magnetic fluid and zoom in and out of measurement area. This study introduces the experimental consideration of the effects of lens for concentrating of magnetic flux. The experimental results showed that the magnetic fluid has sufficient lens effect for magnetic camera and effect of improvement in probability of detection.

  • PDF

Strength Evaluation of Adhesively Bonded Single-Lap Joints by Ultrasonic Signal Analysis (초음파신호해석을 이용한 단순겹치기 접착이음의 강도평가)

  • Oh Seung-Kyu;Jang Chul-Sub;Han Jun-Young;Lee Won
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.32-37
    • /
    • 2004
  • Application of bonding by adhesives can be found in many industries, particularly in advanced technological domains such as aeronautical and space, automobile and electronics industries. Periodic inspection with conventional ultrasonic NDE techniques is capable of indicating the presence and possible location of crack. Continuous ultrasonic attenuation monitoring has potential to supply information. This article discusses the use of pulse-echo ultrasonic testing for the inspection of adhesive bonds between metal sheets. The method is based on the measurement of the reflection coefficient at the metal/adhesive interface. By means of a control experiment it is shown that Quantitative Nondestructive Evaluation in Adhesive Joints are evaluated together with Ultrasonic Testing and Fracture Testing.

A Study on Acoustic Emission Characteristics of MCrAlY Coated Material by Vacuum Plasma Spray Process (진공 플라즈마 용사공정에 의한 MCrAlY코팅재의 음향방출 신호 특성 연구)

  • 박진효;이구현;예경환;김정석;강명창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.921-924
    • /
    • 2004
  • This paper is to investigate a crack for plasma sprayed MCrAlY coated material by acoustic emission method in 4-point bending test. The CoNiCrAlY is coated on Inconel-718 by vacuum plasma spray process. Micro-hardness measurement was conducted by means of Micro Vickers-hardness indentor. The porosity of coating layer was measured using a SEM and Image Analyzer. AE monitoring system is composed of PICO type sensor, a wide band preamplifier(40dB), a PC and AE DSP(16/32 PAC) board. The AE count, Hit and energy of coating specimens is measured according to coating thickness.

  • PDF

A Study on The Compensation Method of Vertical Members of Tall Building (초고층 벽식 건축물의 수직부재 축소량 계측 및 보정)

  • Kim, Woo-Jae;Song, Hwa-Cheol;Park, Hyo-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.404-407
    • /
    • 2004
  • The construction of high-rise buildings is increased. The Vertical Member of tall buildings is inherently shortened and it causes several seriously problems such as tilting of slab, crack within partition wall, deformation of curtain wall. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. In this study, the column shortening according to revised field information and to compare the analysis results the actual field measurement. Pusan The $\#$, a 51-story apartment building which is currently under construction was chosen for the case study.

  • PDF