• Title/Summary/Keyword: Cr equivalent

Search Result 97, Processing Time 0.017 seconds

ONE REMARK FOR CR EQUIVALENCE PROBLEM

  • Hayashimoto, Atusushi
    • Journal of the Korean Mathematical Society
    • /
    • v.37 no.2
    • /
    • pp.245-251
    • /
    • 2000
  • Assume that two boundaries of worm domains, which are parpametrizd by harmonic functions, are CR equivalent. Then we determine the Taylor expansion of CR equivalence mapping and get a relation of harmonic functions.

  • PDF

A study on the tensile property and corrosion resistance of austenitic stainless base and weld metal (오스테나이트계 스테인리스강 모재 및 용접부의 인장특성과 내식성에 관한 연구)

  • 정호신;김조권;엄동석
    • Journal of Welding and Joining
    • /
    • v.14 no.4
    • /
    • pp.71-78
    • /
    • 1996
  • The effect of chemical composition on mechanical properry and corrosion resistance of austenitic stainless steel was investigated. The main results obtained were as follows : 1. There was a linear relationship between the tensile strength of stainless steel and the $Cr_{eq}/Ni_{eq}$. The larger the $Cr_{eq}/Ni_{eq}$ was the higher the tensile strength of stainless steel. 2. There was a good correlationship between $Cr_{eq}/Ni_{eq}$ and intergranular, gerneral corrsion rate. 3. Intergranular corrosion rate decreased linearly with increasing Cr content. 4. General corrosion rate decreased linearly with increasing Ni content. 5. Logarithm corrosion rate of intergranular and general corrosion has a linear relationship with all of the factor of $Cr_{eq}/Ni_{eq}$, Cr and Ni content.

  • PDF

CR MANIFOLDS OF ARBITRARY CODIMENSION WITH A CONTRACTION

  • Kim, Sung-Yeon
    • The Pure and Applied Mathematics
    • /
    • v.17 no.2
    • /
    • pp.157-165
    • /
    • 2010
  • Let (M,p) be a germ of a $C^{\infty}$ CR manifold of CR dimension n and CR codimension d. Suppose (M,p) admits a $C^{\infty}$ contraction at p. In this paper, we show that (M,p) is CR equivalent to a generic submanifold in $\mathbb{C}^{n+d}$ defined by a vector valued weighted homogeneous polynomial.

The Effects of δ-ferrite on Weldment of 9-12% Cr Steels (9-12% Cr강의 용접부에 미치는 δ-ferrite의 영향)

  • Ahn, Sung-Yong;Kang, Namhyun
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.8-16
    • /
    • 2013
  • As the energy consumption increases rapidly, power generation needs the high energy efficiency continuously. To achieve the high efficiency of power generation, the materials used have to endure the higher temperature and pressure. The 9-12%Cr steels possess good mechanical properties, corrosion resistance, and creep strength in high temperature due to high Cr contents. Therefore, the 9-12%Cr steels are widely used for the high-temperature components in power plants. Even though the steels usually have a fully martensitic microstructure, they are susceptible to the formation of ${\delta}$-ferrite specifically during the welding process. The formation of ${\delta}$-ferrite has several detrimental effects on creep, ductility and toughness. Therefore, it is necessary to avoid its formation. As the volume fraction of ${\delta}$-ferrite is less than 2% in microstructure, it has the isolated island morphology and causes no significant degradation on mechanical properties. For ${\delta}$-ferrite above 2%, it has a polygonal shape affecting the detrimental influence on the mechanical properties. The formation of ${\delta}$-ferrite is affected by two factors: a chemical composition and a welding heat input. The most effective ways to get a fully martensite microstructure are to reduce the chromium equivalent less than 13.5, to keep the difference between the chromium and nickel equivalent less than 8, and to reduce the welding heat input.

Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions (400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정)

  • Kim, Sunghwan;Nam, Uk-Won;Lee, Jaejin;Park, Won-Kee;Pyo, Jeonghyun;Moon, Bong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • In this study, equivalent dose and LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) were performed using 400 MeV/u C heavy ions in HIMAC (Heavy Ion Medical Accelerator in Chiba) for high LET radiation therapy. The irradiated CR-39 SSNDTs were etched according the etching condition of JAXA (Japan Aerospace Exploration Agency). And the etched SSNTDs were analyzed by using Image J. Determined frequency mean dose (${\bar{y_D}}$)and dose-mean lineal energy (${\bar{y_F}}$)of 400 MeV/u C are about 8.5keV/mm and 10.1 keV/mm, respectively by using the CR-39 SSNTD. This value is very similar to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC (Tissue Equivalent Proportional Counter) active radiation detector. We could determine the equivalent dose and LET calibration factors of CR-39. And we confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry in hadron radiotherapy.

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Effect of Alloying Elements of Mn and Ni on the Pitting Corrosion Resistance of 22Cr Lean Duplex Stainless Steel (22Cr 린 듀플렉스 스테인리스강의 공식저항성에 미치는 Mn과 Ni 첨가의 영향)

  • Ahn, Y.S.;Bae, K.K.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.76-82
    • /
    • 2012
  • Duplex stainless steels have the dual microstructure of austenite and ferrite phases. This steel exhibits generally a high corrosion resistance and higher mechanical strength compared with austenitic stainless steels. The steels used in the investigation have the chemical composition of Fe-22Cr-xNi-yMn-0.2N in which the contents of Ni and Mn were varied with maintaining the equal [Ni/Cr] equivalent. The fraction of ferrite phase was increased with the increase of annealing temperature. The impact factor of Mn element on the [Ni] equivalent was amended on the basis of the results of the investigation. 4Mn-2Ni alloy showed the highest pitting corrosion resistance. The fraction ratio, grain size and misorientation angle between grains were measured, and the correlation with pitting potential was investigated.

LET Calibration of Fe 500 MeV/u Ions using SSNTD (고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정)

  • KIM, Sunghwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ($\overline{y_D}$) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.

Effect of Thermal History on Pitting Corrosion of High Nitrogen and Low Molybdenum Stainless Steels

  • Kim, Kwangsik;Chang, Hyunyoung;Kim, Youngsik
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.75-81
    • /
    • 2003
  • Chromium, molybdenum. and nitrogen are very important alloying elements in stainless steels and its effect was approved in pitting resistance equivalent (PRE) equations and many experimental results. However, Cr can improve the corrosion resistance, but facilitate the formation of sigma phase. Also. Mo has the same effect in stainless steels. If Cr and Mo are added at high amount to increase the corrosion resistance of stainless steel, corrosion resistance in annealed alloys can be improved, but in case of welding or aging heat treatment. its resistance will be drastically decreased. In this work, increasing Cr and N contents but decreasing Mo than the commercial alloys made the experimental alloys. Typical alloys are 25Cr-4.5Mo-0.43N alloy, 27Cr-4.7Mo-0.4N alloy, 27Cr-5.3Mo-0.25N alloy, 32Cr-2.6Mo-0.36N alloy. After annealing and aging heat treatment, microstructures, anodic polarization test, and pitting corrosion test were performed. Annealed alloys showed $100^{\circ}C$ of CPT and aged alloys showed the different tendency depending upon Cr and Mo contents(SFI)

Fatigue Life Prediction Model of 12% Cr Rotor Steel (12% 크롬 로터강의 피로수명 예측 모델에 관한 연구)

  • 장윤석;오세욱;오세규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1349-1355
    • /
    • 1990
  • By examining the fatigue deformation properties of 12% Cr rotor steel which has been proved to have high fatigue and creep rupture strength around 600deg. C, authors reviewed major fatigue life prediction models such as Manson, Langer and Morrow equations, and following results were obtained. (1) A simple life prediction model for 12% Cr rotor steel was obtained as follows : DELTA..epsilon.$_{t}$ =2.18+.sigma.$_{u}$ /E+ $N^{-0.065}$+ $e^{0.6}$ $N^{-0.025}$ This equation shows that fatigue life, N, can be easily determined when total strain range, DELTA..epsilon.$_{t}$ and ultimate tensile strength, .sigma.$_{u}$ are known by simple tension test on the given test conditions. (2) Life prediction equation with equivalent maximum stress, DELTA..sigma./2, corresponding maximum strain in one cycle at room temperature is as follows: DELTA..sigma./w=-7.01logN+96.69+96.69