• Title/Summary/Keyword: Cr 층

Search Result 457, Processing Time 0.026 seconds

Fine Granulation of Recording Layer in Perpendicular Magnetic Recording Media Using Oxide-interlayer (산화막중간층에 의한 수직자기기록층의 입자크기 미세화)

  • 김경환;공석현
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.4
    • /
    • pp.196-199
    • /
    • 2004
  • Seedlayers with low surface energy which increases the density of nucleation sites in the initial growth region of the recording layer deposited on them was studied to reduce grain size in recording layer. The seedlayer with low surface energy was so effective to attain finer grain in magnetic upper-layers. The Ni-Fe-O intermediate layer with low surface energy was found to be effective in reduction of grain size as well as magnetic cluster size of Co-Cr-Ta-Pt recording layer. Furthermore, the reduction of grain size in Co-Cr-Ta-Pt recording layer on Ni-Fe-O intermediate layer with low surface energy led to decrease the noise level in the high recording density region.

The Effect of Trace Metallic Additives on Microstructure, Surface Appearance and Hardness of Zn Electrodeposits (아연도금층의 조직, 외관, 및 경도에 미치는 미량 금속첨가의 영향)

  • 예길촌;김대영;안덕수
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.1
    • /
    • pp.28-39
    • /
    • 2004
  • The effect of trace metallic additives on microstructure, surface appearance and hardness of zinc electrodeposits was investigated by using sulfate bath and flow cell system. The preferred orientation of Zn deposit with Fe additive was (103)(104)+(002) mixed texture and that of Zn deposits with both Fe-Ni and Fe-Co additives was (10 1), while Zn deposits with Fe-Cr additives had (002) preferred orientation. The surface morphology of the zinc deposits was closely related to the preferred orientation of the deposits. The glossiness of Zn deposit with Fe-Ni additives was higher than that of pure Zn deposit, while the glossiness of Zn deposits with both Fe-Co and Fe-Cr additives was lower than that of pure Zn deposit. The hardness of Zn deposits with both Fe-Ni and Fe-Co additives was noticeably higher than that of Zn-Fe deposit, while that of Zn deposit with Fe-Cr additives was similar to that of Zn-Fe deposit.

Microstructure and Hardness Distributions of $CO_2$ Lser Hrdened 12%-Cr Seel (12%-Cr 강의 $CO_2$ 레이저 표면경화에서 금속조직과 경도분포)

  • 김재도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1861-1868
    • /
    • 1992
  • Laser beam hardening of 12%-Cr steel has been evaluated by using a continuous wave 3kW co$_{2}$ laser with a hardening mirror set. Experiment was performed on the hardening condition with a laser power of 2.85kW and travel speed of 1.0 and 1.5m/min. Multi passes have been also tried to find the hardening characteristics of partly overlapped zone. The black paint to use at high temperature was adopted to increase the absorptivity of laser beam energy with the wavelength of 10.6.mu.m at the surface of base metal. The microstructure of the hardened layers was observed by using a light microscopy, SEM and TEM. A fine Lamellar martensite formed in the hardened zones exhibits very high Vickers microhardness of 600Hv, whereas the tempered martensite distributes in the base metal with Vickers microhardness of 240Hv.It has been found that laser hardening with multi passes showed no significant drop of the hardness between adjacent passes.

Effect of Trace Metallic Additives of Mg-Fe-X on Microstructure and Properties of Zn Electrodeposits (아연도금층의 조직 및 물성에 미치는 미량금속원소(Mg-Fe-X)의 복합첨가의 영향(II))

  • 예길촌;김대영;안덕수
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2004
  • The effect of trace metallic additives on microstructure, glossiness and hardness of Zinc electrodeposits was investigated by using sulfate bath and flow cell system. The preferred orientation of Zn deposits with Mg-Fe additives was (10$\ell$)+(002) mixed texture, while that of Zn deposits with Mg-Fe-Cr additives was ( $10\ell$). The preferred orientation of Zn deposits with Mg-Fe-X(X:Ni,Co) additives changed from ($10\ell$)+(002) to ($10\ell$) with increasing Mg additive from 5 to 10 g/$\ell$. The surface morphology of the Zinc deposits was closely related to the preferred orientation of the deposits. The glossiness of Zn deposits with Mg-Fe additives was similar to that of pure Zn deposit. The glossiness of Zn deposits with Mg-Fe-X(X:Ni,Cr) additives was lower than that of Zn deposits with Mg-Fe additives, while that of Zn deposits with Mg-Fe-Co additives was higher than that of Zn-Mg-Fe deposits. The hardness of Zn deposits with Mg-Fe-X(Ni,Co,Cr) increased with current density and amount of Mg additive. Hardness of Zn deposits was decreased and increased in comparison with Zn-Mg-Fe deposits for Mg-Fe-Co and Mg-Fe-Cr additives, respectively.

Evaluation of Bond Strength in cp-Ti and Non-precious Metal-Ceramic System Using a Gold Bonding Agent (티타늄과 비귀금속 합금에 중간층으로 적용한 Au bonding agent의 금속-도재 결합에 대한 평가)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.31 no.4
    • /
    • pp.15-23
    • /
    • 2009
  • The aim of this study was to evaluate the bond strength of using a Au bonding agent applied on cp-Ti and nonprecious metal-gold-ceramic system. Metallic frameworks(diameter: 5mm, height: 20mm)(N=56, n=7per group) cast in Ni-Cr alloy, Co-Cr alloy and cp-Ti were obtained using acrylic templates and airborne particle abraded with $110{\mu}m$ aluminum oxide. Au bonding agent was applied on wash opaque firing as intermediate layer. SEM and SEM/EDS line profile were performed on the cutting the cross-section of the metal substrate-porcelain with intermediate Au coating. Groups were tested using shear bond strength(SBS) testing at 0.5mm/min. The mean SBS values for the ceramic-Au layer-metal combination were significantly higher than those ceramic-metal combination. While ceramic-Au layer-cp-Ti combinations failed to increase bond strength instead of using a titanium bonding porcelain. The appication of using Au intermediate layer significantly improve the bond strength combination with metal-ceramic system.

  • PDF

A Study on the Magnetic Properties and Microstructure of CoCr Thin Films Growing under Magnetic Field (자장하에서 성장한 CoCr박막의 자기적 특성 및 미세구조에 관한 연구)

  • Lee, Yu-Gi;Jang, Pyeong-U;Lee, Taek-Dong;Lee, Gye-Won
    • Korean Journal of Materials Research
    • /
    • v.4 no.5
    • /
    • pp.581-589
    • /
    • 1994
  • Magnetic properties and microstructures of the $Co_{83}Cr_{17}$ films growing under the applied magnetic field were studied. In comparison, those of the films growing without magnetic field were also studied. Magnetic field does not affect saturation magnetization and in-plane coercivity of the films. On the contrary perpendicular coercivity and effective perpendicular anisotropy field decreased. Grain size and the thickness of the so-called transition layer were not affected and the C-axis alignment of the films was slightly deteriorated due to magnetic field. Also, microstructures of the sputtered films showed larger grain sizes of strong (002) preferred orientation for thicker film specimens independent of applied magnetic field.

  • PDF

Fabrication of MISFET type hydrogen sensor for high Performance (고성능 MISFET형 수소센서의 제작과 특성)

  • Kang, K.H.;Park, K.Y.;Han, S.D.;Choi, S.Y.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.4
    • /
    • pp.317-323
    • /
    • 2004
  • We fabricated a MISFET using Pd/NiCr gate for the detecting of hydrogen gas in the air and investigated its electrical characteristics. To improve stability and high concenntration sensitivity and remove the blister generated by the penetration of hydrogen atoms Pd/NiCr catalyst gate metal are used as dual gate. To reduce the gate drift voltage caused by the inflow of hydrogen, the gate insulators of sensing and reference FFET were constructed with double insulation layers of silicon dioxide and silicon nitride. The hydrogen response of MISFET were amplified with the difference of gate voltages of both MISFET. To minimize the drift and the noise, we used a OP177 operational amplifier. The sensitivity of the Pd/NiCr gate MISFET was lower than that of Pd/Pt gate MISFET, but it showed good stability and ability to detect high concentration hydrogen up to 1000ppm.

Effect of Flame Spray Distance on Particle Behavior and Morphological Characteristics of $Ni_{20}Cr$ Coated Layers (화염용사 거리에 따른 입자의 거동 및 $Ni_{20}Cr$ 코팅층 특성 연구)

  • Lee, Jae Bin;Shin, Dong Hwan;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.17 no.3
    • /
    • pp.128-133
    • /
    • 2012
  • The present study aims to examine the influence of flame spray distance on the thermal behavior of micro-metal particles and the morphological characteristics of $Ni_{20}Cr$ layers coated on the preheated SCM415 substrates by using the conventional flame spray system. Commercially available nickel-based $Ni_{20}Cr$ particles with a mean diameter of $45{\mu}m$ were used. In addition, CFD simulations using a commercial code (FLUENT ver. 6.3.26) were conducted to estimate temperature and velocity distributions of the continuous and discrete phases before impact on the substrate. From FE-SEM images of coated layers on the substrates, it was observed that as the spray distance decreased, the metal particle morphology showed splash-like patterns and such a short stretch shape, resulting from higher particle momentums and the impact of partially melted particles. Moreover, it was found that the spray distance should be considered as one of important parameters in controlling the porosity and the adhesion strength.