• Title/Summary/Keyword: Cr$Cr^{6+}$

Search Result 2,929, Processing Time 0.032 seconds

$Cr^{6+}$ leaching property of cement using high performance lignin (고성능 혼화제를 이용한 시멘트의 $Cr^{6+}$ 용출특성)

  • Park, Hyun;Kim, Kyung-Nam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.3
    • /
    • pp.135-143
    • /
    • 2009
  • To study possibility of $Cr^{6+}$ solid solution and efficiency of admixture, leaching property of Portland cement mortar was investigated by using KSLT (Korea Standard Leaching Test), TCLP (Toxicity Characteristic Leaching Procedure), Soacking procedure, as adding excess $Cr^{6+}$. As a result, admixture of lignin type showed high compressive strength of mortar but no changing leaching property.

Studies on Atomic Absorption Spectrophotometric Analysis of Hexavalent Chromium in Waste Water by Solvent Extraction (용매 추출법에 의한 폐수중 6가크롬의 원자흡수 분광분석에 관한 연구)

  • Eung-Pyo Kim;Young-Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.423-432
    • /
    • 1986
  • Atomic absorption spectrophotometric (AAS) determination of hexavalent chromium [Cr(VI)] in a waste water was studied. Cr(VI) was extracted with p-xylene from the wastewater, in the way of ion pair formation with anion exchanger aliquat-336(tri-caprylmethyl ammonium chloride). 100ml waste water, after organic materials were extracted out with toluene, was acidified with conc. HCl adjusting the medium to pH 0.5 and 20ml of p-xylene containing 0.01M aliguat-336 was used to extract Cr(VI) from the acidified solution. The absorbance of chromium was measured with air-acetylene flame at 357.9nm. Standard addition method was used in the determining concentration of Cr(VI) extracted. No interference has been found in the extraction of Cr(VI) by the Al(III), Fe(III) and Cr(III) ion presented. However, Fe(II) decreased the absorbance of Cr(VI), due to the fact Fe(II) reduces Cr(VI) to Cr(III). The contained organic material was removed prior to extracting process, since it may reduced the absorbance of Cr(VI). The recovery of added Cr(VI) was over 96%, which seems to be promising and the relative standard deviation was 3.95%

  • PDF

Optimal timing for salvage surgery after definitive radiotherapy in hypopharyngeal cancer

  • Chun, Seok-Joo;Keam, Bhumsuk;Heo, Dae Seog;Kim, Kwang Hyun;Sung, Myung-Whun;Chung, Eun-Jae;Kim, Ji-hoon;Jung, Kyeong Cheon;Kim, Jin Ho;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.192-199
    • /
    • 2018
  • Purpose: Use of radiotherapy combined with chemotherapy is increasing in hypopharyngeal cancer. However, many show residual tumor after radiotherapy. Timing for treatment evaluation and salvage therapy is essential. However, optimal timing for salvage surgery has not been suggested. In this study, we tried to evaluate optimal timing for salvage surgery. Methods and Materials: Patients who were diagnosed with hypopharyngeal squamous cell carcinoma between 2006 and 2015 were retrospectively analyzed. All patients received definitive radiotherapy with or without chemotherapy. Response of all treated patients were analyzed at 1, 3, and 6 months after radiotherapy. Any patients with progression before 6 months were excluded. Results: A total of 54 patients were analyzed. Complete remission (CR) rates at 1 month (CR1), 3 months (CR3) and 6 months (CR6) were 66.7%, 81.5%, and 90.7%, respectively. Non-CR at 1 month (NCR1), 3 months (NCR3), and 6 months (NCR6) showed poor locoregional recurrence-free survival rates (1-year rates of 63.7%, 66.7%, and 0.0%, respectively) compared to CR1, CR3, and CR6 (1-year rates 94.3%, 88.0%, and 91.5%, respectively). Particularly significant differences were seen between CR6 and NCR6 (p < 0.001). Of 10 patients with NCR3, 5 showed CR at 6 months (NCR3/CR6). There was no statistical difference in locoregional recurrence-free survival between CR3 and NCR3/CR6 group (p = 0.990). Conclusion: Our data suggest half of patients who did not show CR at 3 months eventually achieved CR at 6 months. Waiting until 6 months after radiotherapy may be appropriate for avoiding additional salvage therapy.

Thermal Cycle Reliabilties and Cracking Characteristics of Electroplated Cr/Ni-P Coatings (전해 Cr/Ni-P 도금막의 열 사이클 신뢰성 및 균열거동 분석)

  • Lee, Jina;Son, Kirak;Lee, Kyu Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.133-140
    • /
    • 2019
  • The effects of thermal cycle conditions on the bonding strength and crack propagation behaviors in electroplated Cr/electroplated Ni-P coatings were systematically evaluated. 1st heat treatment was performed at 500℃ for 3 hours after electroplating Ni-P, and then, 2nd heat treatment was performed at 750℃ for 6 hours after electroplating Cr. The measured bonding strength by ASTM C633 were around 25.6 MPa before thermal cycling, while it increased to 47.6 MPa, after 1,000 cycles. Increasing thermal cycles led to dominant fail mode with cohesive failure inside adhesive, which seemed to be closely related to the increasing bonding strength possibly not only due to higher Cr surface roughness, but also to penetrated channeling crack density. Also, increasing density of penetrated channeling cracks in electroplating Cr layer led to slightly stronger bonding strength due to mechanical interlocking effects of adhesive inside channeling cracks.

Quality Characteristics and Antioxidant Activity of Sikhe prepared using Hot Water Extracts of Roasted Coffee Ground Residue (커피박 열수추출물로 제조한 식혜의 품질 특성 및 항산화 활성)

  • Park, La-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.470-476
    • /
    • 2014
  • This study was performed to evaluate the quality characteristics and antioxidant activity of sikhe prepared using various concentrations of hot water extracts roasted coffee ground residue (CR-sikhe; 0.2, 0.4, 0.6, 0.8, and 1.0%). The pH increased with increasing CR concentration. The reducing sugar content after 5 h saccharification was the highest when 0.8% CR extract was used. Total polyphenol and flavonoid contents increased in a concentration-dependent manner reaching maximum levels when 1.0% CR-extract was used. The antioxidant activities of CR-extracts were higher than that of the control and increased dose-dependently. The CR-0.6 showed the best taste (4.28), color (4.56), flavor (4.08), and overall acceptability (4.28). After 10 day of storage at $4^{\circ}C$, the total cell count in CR-sikhe was approximately 1-2 log cycle, which was less than that in the control.

Corrosion Behavior and Crystal Structure of Zn-Cr Coatings by EB-PVD and Electroplating (EB-PVD법과 전기화학방법으로 형성된 Zn-Cr film의 구조와 부식특성)

  • 최한철
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.6
    • /
    • pp.423-429
    • /
    • 2003
  • It has been investigated corrosion resistance and crystal structure of Zn-Cr coatings fabricated by electroplating method and electron-beam physical vapor deposition method(EB-P VD). The electroplated Zn-Cr alloy consists mainly of η'-Zn phase for the lower Cr content than 7.9 wt% Cr and ${\gamma}$'-ZnCr phase for the higher Cr content. In the Zn-Cr alloy fabricated by EB-PVD the ${\gamma}$'-ZnCr phase appeared clearly at 3 wt% Cr and it became the sole phase at 50 wt%Cr. The amount of η'-Zn phase decreased obviously with increasing Cr content when it exceeded 15 wt% Cr. The electrochemical measurement of the electroplated Zn-Cr film has shown corrosion potential of about -1000 mV. The current density of active region and the amount of dissolved Zn and Cr decreased significantly with increasing Cr content. The electrochemical characteristics of Zn-Cr alloy fabricated by EB-PVD have shown that the alloy of 50 wt% Cr had the highest corrosion potential(-500 mV) and the lowest critical passive current density than that of the electroplated.

Effects of Dietary Chromium Picolinate Supplementation on Growth Performance and Immune Responses of Broilers

  • Lee, Der-Nan;Wu, Fu-Yu;Cheng, Yeong-Hsiang;Lin, Rong-Shinn;Wu, Po-Ching
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.227-233
    • /
    • 2003
  • Two experiments were conducted to evaluate the effects of chromium (Cr) on the growth performance, bone trait, serum traits, and immune responses in broilers. The broilers were fed corn-soybean meal basal diet supplemented with Cr at level of 0(control), 200, 400, or 800 ppb in the form of chromium picolinate (CrPic). The broilers were fed treated diets for 6 weeks in Exp. 1, but the Cr supplement was removed for the last 3 weeks in Exp. 2. Exp. 1 showed that dietary supplement of Cr did not affect growth performance of the broiler, though improved feed efficiency (p<0.05) was observed during 0 to 3 weeks. Moreover, serum total (p<0.05) and HDL cholesterols (p<0.06) were significantly higher in pooled Cr added group at 6 weeks of age, however, the difference was not significant in Exp. 2. The pooled Cr added group in Exp.1 had significantly lower (p<0.05) alkaline phosphatase activity and higher (p<0.09) calcium at 3 weeks. Significantly lower phosphorus was also observed in Exp. 2. With continued supplement of Cr as in Exp. 1, the alkaline phosphatase activity maintained higher at 6 weeks, as opposed to significantly lower in Exp. 2, which had no further Cr supplement. Higher bone breaking strength was observed in 400 ppb Cr supplemented in Exp. 1, though not significantly different. Serum glucose and triglyceride were not affected by Cr supplement. Antibody against Infectious Bronchitis (IB) was significantly (p<0.05) higher with 400 ppb Cr supplemented, and anti-Newcastle disease (ND) antibody also tended to be higher (p<0.06) in pooled Cr added group at 6 weeks of age in Exp. 1. Peripheral blood blastogenesis activity was not different among the treatments. The results suggest that diet supplemented with 400 ppb CrPic may be beneficial to the broiler.

Development of Highly Conductive and Corrosion-Resistant Cr-Diamond-like Carbon Films

  • Ko, Minjung;Jun, Yee Sle;Lee, Na Rae;Kang, Suhee;Moon, Kyoung Il;Lee, Caroline Sunyong
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.317-324
    • /
    • 2019
  • Cr-diamond-like carbon (Cr-DLC) films were deposited using a hybrid method involving both physical vapor deposition and plasma-enhanced chemical vapor deposition. DLC sputtering was carried out using argon and acetylene gases. With an increase in the DC power, the Cr content increased from 14.7 to 29.7 at%. The Cr-C bond appeared when the Cr content was 17.6 at% or more. At a Cr content of 17.6 at%, the films showed an electrical conductivity of > 363 S/cm. The current density was 9.12 × 10-2 ㎂/㎠, and the corrosion potential was 0.240 V. Therefore, a Cr content of 17.6 at% was found to be optimum for the deposition of the Cr-DLC thin films. The Cr-DLC thin films developed in this study showed high conductivity and corrosion resistance, and hence, are suitable for applications in separators.

Porcelain Bonding Strength and Mechanical Properties of Sintered Ni-Cr-Ti Alloy for Dental Prosthodontics (치과보철용 Ni-Cr-Ti 소결체합금의 포셀린결합력 및 기계적 특성)

  • Choe, Han-Cheol;Park, Seon-Yeong;Shim, Myung-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.560-566
    • /
    • 2016
  • In this study, porcelain bonding strength and mechanical properties of sintered Ni-Cr-Ti alloy for dental prosthodontics have been researched experimentally. Mechanical and morphological characteristics of the alloys were examined by Vickers hardness test, tensile and bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. In the sintered Ni-13Cr-xTi alloys, morphology of sintered alloy showed porous matrix diffused with alloying elements of Cr and Ti, and showed dendritic structure after melting process. From the XRD results, the second phases of NiCr, $Ni_3Cr$, and $Ni_3Ti$ were formed in the case of sintered and melted Ni-13Cr-xTi alloys. The tensile strength and hardness of Ni-13Cr-xTi alloys increased, as Ti content increased. Surface roughness increased, as Ti content increased. The bonding strength between metal and porcelain of Ni-13Cr-5Ti alloy was higher than those of Ni-13Cr and Ni-13Cr-10Ti alloys

Electrical Characteristics and Fabrication of NiCr/NiCrSi Alloy Film for High Precision Thin Film Resistors (고정밀급 박막저항을 위한 NiCr/NiCrSi박막의 제조 및 전기적 특성)

  • Lee, Boong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.520-526
    • /
    • 2007
  • In order to acquire fundamental informations to fabricate high precision thin film resistors, NiCr/NiCrSi alloy films were prepared using Ni and Cr targets. Effect of composition on the electrical properties of the NiCr/NiCrSi alloy film were then investigated. Considering the effect of Si doping on the electrical and material characteristics, the lower TCR (temperature coefficient of resistance) values could be achieved for samples with Ni/Cr ratio of $0.8{\sim}1.5$ (in a range of relative higher specific resistivity and Cr composition of $40\;wt%{\sim}55\;wt%$) and with Si doping. Consequently, the sample prepared using a DC power showed a good TCR of $-25\;ppm/^{\circ}C$, which implies that increase of specific resistivity and decrease of TCR would be achieved more efficiently not for Ni-Cr binary material but for Si doped Ni-Cr ternary material, and not using RF power but using DC power in the sputtering process.