• Title/Summary/Keyword: Covering thickness

Search Result 142, Processing Time 0.028 seconds

Design of Dual Band Antenna for Broadband Wireless LAN (광대역 무선랜용 이중대역 안테나 설계)

  • Kim, Kab-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.181-185
    • /
    • 2017
  • In this paper, for Broadband Wireles LAN dual-band antenna was designed to satisfy the bandwidth of 2.32GHz and 5.79GHz. the substrate of proposed microstrip antenna is FR-4(er=4.3) and $34mm{\times}50mm{\times}1.5mm$ size and thickness t=0.035mm, and the simulation was used for CST Microwave Studio 2014. input return loss compared -10dB less than operates at and when gain 2.32GHz -19.321dB, 5.79GHz showed the results of -13.033dB. It increased impedance matching, minimized interference between adjacent frequencies, simplified small manufacturing methods, and demonstrated the characteristics of non-directional properties. Thus the proposed antenna satisfied the -10 dB impedancebandwidth requirement while simultaneously covering the Broadband Wireless LAN.

Temporal augmentation with calvarial onlay graft during pterional craniotomy for prevention of temporal hollowing

  • Kim, Ji Hyun;Lee, Ryun;Shin, Chi Ho;Kim, Han Kyu;Han, Yea Sik
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Background: Atrophy of muscle and fat often contributes to temporal hollowing after pterional craniotomy. However, the main cause is from the bony defect. Several methods to prevent temporal hollowing have been introduced, all with specific limitations. Autologous bone grafts are most ideal for cranial defect reconstruction. The authors investigated the effectiveness of bony defect coverage and temporal augmentation using pterional craniotomy bone flap. Methods: This study was conducted in 100 patients who underwent brain tumor excision through pterional approach from 2015 to 2016. Group 1 underwent pterional craniotomy with temporal augmentation and group 2 without temporal augmentation. In group 1, after splitting the calvarial bone at the diploic space, the inner table was used for covering the bone defect and as an onlay graft for temporal augmentation. The outcome is evaluated by computed tomography at 1-year follow-up. Results: The mean operative time for temporal augmentation was 45 minutes. The mean follow-up was 12 months. The ratio of temporal thickness of operated side to non-operated side was 0.99 in group 1 and 0.44 in group 2, which was statistically different. The mean visual analogue scale score was 1.77 in group 1 and 6.85 in group 2. Conclusion: This study demonstrated a surgical technique using autologous bone graft for successfully preventing the temporal hollowing and improved patient satisfaction.

An Analytical DC Model for HEMT's (헴트 소자의 해석적 직류 모델)

  • Kim, Young-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.38-47
    • /
    • 1989
  • A purely analytical model for HEMT's based on a two dimensional charge control simul-ation[4] is proposed. In this model proper treatment of diffusion effect of electron transport along a 2-DEG (two dimensional electron gas) channel is perfoemed. This diffusion effect is shown to effectively increase the bulk mibility and threshold voltage of the I-V curves compared to the existing models. The channel thickness and gate capacitance are expressed as functions of gate voltages covering subthreshold characteristics of HEMT's analytically. By introducing the finite channel opening and an effiective channel-length modulation, the solpe of the saturation region of the I-V curves ws modeled. The smooth transition of the I-V curves at linear-to-saturation regions of the I-V curves was possible using the continuous Troffimenkoff-type of field dependent mobility. Furthermore, a correction factor f was introduced to account for the finite transition section forming between a GCA and a saturated section. This factor removes large discrepancies in the saturation region of the I-V curve predicted by existing l-dimensional models.

  • PDF

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Carbon Fiber Tow Spreading Technology and Mechanical Properties of Laminate Composites (탄소섬유 펼침 기술 및 이를 적용한 적층 복합재료의 기계적 특성)

  • Park, Sung Min;Kim, Myung Soon;Choi, Yoon Sung;Lee, Eun Soo;Yoo, Ho Wook;Chon, Jin Sung
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.249-253
    • /
    • 2015
  • This paper reports a study on a method for achieving lightweight thermoplastic laminate composites referred to as tow spreading technology. Thickness of an unspread 12 K carbon fiber tow is reduced by increasing the tow width from 7 mm to 20 mm. The polypropylene (PP) film was used to stabilize and impregnate the spread tow, covering it into a partially consolidated prepreg: 12 K carbon fiber spread tow/PP. Laminates were fabricated from the spread tow prepreg and control laminate composites were produced from unspread tow prepreg consisting of 12 K carbon fiber and PP. The void content, tensile and flexural properties of the composite laminates were investigated. Consequently, the spread tow laminate composite exhibited lower void content and improved mechanical properties.

Effect of Cultivation Type in Different Greenhouses on Growth and Yield of Green Pepper (Capsicum annuum) (시설유형별 재배방식이 풋고추 생육과 수량에 미치는 영향)

  • Hee Chun;Kyung Je Kim;Young Hoe Woo
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.225-231
    • /
    • 2001
  • This study was conducted to examine effect of different environment conditions in glass, PC, PET and PE greenhouses controlled by different environment control systems on the growth of green pepper. Light transmittance of 64.7% in the glass greenhouse was the highest among different green-houses. Air temperature was the highest in the glass greenhouse when ventilators were closed, and was the highest in the PE greenhouse when ventilators were open. Air relative humidity was the highest in the PE greenhouse during 24 hours. The amount of solar energy accumulated in soil was the greatest in the glass greenhouse and this energy released during the night escaped through covering materials. Latent heat and solar energy affected air temperature increased in greenhouses. The air temperature of glass greenhouse was 27.5$^{\circ}C$ at 11 O clock, which was the highest air temperature among the all greenhouse types. Clear differences were observed in leaf area and plant height at 30 days after transplanting. Days to first flowering was the shortest in the glass greenhouse with 72.7 days. Flower shedding was the greatest in the PE greenhouse with 12.6%. Days to fruit harvesting was the shortest in the glass greenhouse with 14.3 days. Fruit quality, such as fruit length, fruit diameter, fruit flesh thickness, and vitamin C content, was the best in the glass greenhouse. Percent marketable fruits was the highest with 95.3% when the pepper was grown hydroponically in the glass greenhouse.

  • PDF

The Relationship between Weight of Single Garments and Thermal Insulation with a Thermal Manikin (써멀마네킨을 이용한 단일의복의 중량과 보온력에 관한 연구)

  • Choi, Jeong-Wha;Lee, Hyo-Hyun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.2
    • /
    • pp.173-186
    • /
    • 2009
  • The purpose of this study was to examine the relationship between the weight of seasonal garments worn by Korean women in their daily lives and thermal insulation. We selected a total of 121 garments(13 kinds of Under garments, 51 Upper garments, 32 Lower garments, 15 Headgear, 10 Gloves Footgear) based on our previous survey using questionnaire and interview. Thermal insulation of single garment was measured with a thermal manikin. Also we measured garment weight, covering area, thickness, air permeability on the each garment(chamber air temperature: $21.5{\pm}0.5^{\circ}C$, humidity: $50{\pm}5%R.H.$ air speed: 0.15m/s). The results are as follow: The very strong positive correlation(r=0.905, p<.01) was recognized between the weight of single garment and thermal insulation. The regression equation of thermal insulation can be represented as follows: Thermal Insulation(clo)=$0.03+0.0004{\times}Garment$ Weight(g)($r^2$=0.820, SEE =0.059). There are significant differences in the thermal insulation and garment weight by season and garment type(p<.05). The each garment category's thermal insulation and garment weight has as follows: Under garment(0.06clo, 89g), Blouse Shirt T-shirt(0.13clo, 200g), Cardigan Sweater Vest(0.14clo, 287g), Coat Jacket Jumper(0.41clo, 890g), Skirt(0.16clo, 276g), Trousers(0.20clo, 438g), Headgear(0.03clo, 102g), Gloves Footgear(0.03clo, 33g).

Reconstruction of Pretibial Defect Using Pedicled Perforator Flaps

  • Shin, In Soo;Lee, Dong Won;Rah, Dong Kyun;Lee, Won Jai
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.360-366
    • /
    • 2012
  • Background Coverage of defects of the pretibial area remains a challenge for surgeons. The difficulty comes from the limited mobility and availability of the overlying skin and soft tissue. We applied variable pedicled perforator flaps to overcome the disadvantages of local flaps and free flaps on the pretibial area. Methods Eight patients who had the defects in the anterior tibial area were enrolled. Retrospective data were obtained on patient demographics, cause, defect location, defect size, flap dimension, originating artery, pedicle length, pedicle rotation, complication, and postoperative result. The raw surface created following the flap elevation was covered with a split thickness skin graft. Results Posterior tibial artery-based perforator flaps were used in five cases and peroneal artery-based perforator flaps in three cases. The mean age was 54.3 and the mean period of follow-up was 6 months. The average size of the flaps was 63.8 $cm^2$, with a range of 18 to 135 $cm^2$. There were no major complications. No patients had any newly developed functional deficit of the lower leg. Conclusions We suggest that pedicled perforator flaps can be an alternative treatment modality for covering pretibial defects as a simple, safe and versatile procedure.

Effect of Deposition Time and Pressure on Properties of Selective CVD-W by $SiH_4$ Reduction ($SiH_4$ 환원에 의한 Selective CVD-W막 특성에 대한 증착시간과 압력의 효과)

  • Lee, Chong-Mu;Lee, Kang-Uk;Park, Sun-Hoo
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.177-183
    • /
    • 1991
  • Change of the properties of selective CVD-W by $SiH_4$ reduction with the variation of deposition time and pressure has been investigated. The lime required for covering the who)to Si substrate by tungsten at $300^{\circ}C$ under the pressure of 100mtorr is approximately 30 seconds. The film thickness tends to increase linearly in the early stage of deposition process and parabolically later, sheer resistance of the film tends to decrease rapidly initially, and slowly later with deposition time. Tungsten grain size does not change much, but grain boundary becomes hazy in the pressure range of 50-300mtorr. Also no ${\beta}-W$ but only ${\alpha}-W$ was found in this pressure range. The deposition rate and electrical resistivity of tungsten tend to increase wish increasing pressure. The results of AES analysis show that pressure does not much affect Si/W ratio of the tungsten film and silicidation at the W/Si interface.

  • PDF

A Study on the Applicability of Soil-Media Hydroseeding Measures Using Zoysiagrass's Lateral Stems (한국잔디 줄기를 이용한 식생기반재 뿜어붙이기공법의 적용성 연구)

  • Min, Chang-Hyun;Kim, Nam-Choon;Choi, Joon-Soo;Song, Wonkyong;Joo, Sang-Dae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.4
    • /
    • pp.1-14
    • /
    • 2015
  • A manipulation of zoysiagrass's lateral stems and soil-media; used for slope revegetation, is expected to facilitate the production of high-quality grass. To study the influences on the growth of zoysiagrass depending upon various soil-media conditions, two different types of soil are used. The results obtained - through investigation of its cover rates, leaf color and number - are summarized as follows. In mountain regions soil, there are no significant differences in growth and development of grass in treatments: zoysiagrass's lateral stems treatments with 1cm, 2cm, and 3cm soil-media and treatment with only seeding. Zoysiagrass, in most of the treatments, show about the same growth rates, and at the end, fair visual quality. Zoysiagrass's lateral stems treatments with 2cm, 3cm show slightly better growth, however, thickness of soil-media need not be more than 1cm to obtain an expected quality of lawn. In decomposed granite soil, there appears statistical significance in growth of the grass in treatments: zoysiagrass's lateral stems treatments with 1cm, 2cm, and 3cm soil-media and treatment with only seeding. The thicker the soil-media, the better the growth of grass, and that in treatment with seeding-only shows poor quality in general. And therefore, it is efficacious to plant in 3cm soil-media when quick formation of lawn is necessary; however, using 2cm soil-media is ultimately the most cost-efficient way of formation. But, when time allows - that is, more than three months - 1cm soil-media in decomposed granite soil is reasonable to formate just as effective lawn. And so when performing seeding, additional covering, fertilization or increasing the quantity of seed must be considered.