• 제목/요약/키워드: Covering area ratio

검색결과 45건 처리시간 0.028초

무인헬리콥터를 이용한 항공방제시스템 개발(I) - 항공방제시스템 구축을 위한 기초 분무특성 - (Development of Aerial Application System Attachable to Unmanned Helicopter - Basic Spraying Characteristics for Aerial Application System -)

  • 강태경;이채식;최덕규;전현종;구영모;강태환
    • Journal of Biosystems Engineering
    • /
    • 제35권4호
    • /
    • pp.215-223
    • /
    • 2010
  • In order to develop an precision aerial pesticide application system to be attached to an unmanned helicopter which can be applied to small lots of land, this study analyzed the flowing and spraying characteristics of the spray droplets by the main rotor downwash by setting the application conditions at the flight altitude of 3 m, the diameter of main rotor of 3.1 m, the boom length of around 2.8 m, and the spraying rate of 8 L/ha. The results of this study are summarized below. Through analysis of the covering area ratio of the spray droplets by main rotor downwash by nozzle type, boom with tilt angle and height, it was found that the covering area ratio of the twin flat-fan nozzle of around 25% was more uniform than other types of nozzle, also boom with $10^{\circ}$ tilt angle and spraying height of 3 m was shown to be the appropriate conditions for aerial application of pesticides. It was found that the nozzle position to minimize the scattering loss of spray droplets due to vortex phenomenon at both ends of the main rotor was around 10 cm from the end of the main rotor. An application test for the aerial pesticide application system attached to the HUA-ACEI unmanned helicopter developed by the Rural Development Administration showed that the range of covering area ratio of the spray droplets was 10-25%, and the spraying width was approximately 7 m when over 10% of covering area ratio was considered for valid spraying.

투수성 포장도로 도입을 통한 보광배수유역 유출량 저감효과 검토 (Effects of porous pavement on runoff reduction in Boguang subcatchment)

  • 정지윤;이건영;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.251-259
    • /
    • 2013
  • Among various Green Infrastructure measures for urban stormwater management, effects of porous pavement were quantitatively examined in terms of hydrological cycle. Different scenarios for porous pavement were introduced on a SWMM model and the effects were compared and analysed using discharge hydrographs. Two types of pavements having different runoff coefficients (0.05 & 0.5) were introduced to cover different ratio of entire road areas (100 %, 77.5 % and 40.4 %) and these made up in total 6 different scenarios. Total runoff volume was reduced and peak flow was significantly decreased by applying the porous pavement. The highest reduction for total runoff was shown from S-6(covering area: 100 %, runoff coefficient: 0.05) as 19 % followed by S-5(covering area: 77.5 %, runoff coefficient: 0.05, 16 %), while that of S-2(covering area: 40.4 %, runoff coefficient: 0.05) and S-1(covering area: 40.4 %, runoff coefficient: 0.5) were the lowest with 8 % and 5 %. This proved that the application of porous pavement would improve urban hydrological cycle.

둘 이상의 용도지역 등에 걸치는 대지에 대한 용적률 적용기준 변경의 정책적 효과분석 - 강남구를 중심으로 - (An Analysis of the Policy Effect on the Change of Application Standard of Floor Area Ratio for Land Covering Two or More Zoning Area - Focused on Gangnam-gu -)

  • 유명한;이창무
    • 지적과 국토정보
    • /
    • 제48권2호
    • /
    • pp.121-135
    • /
    • 2018
  • 국토교통부는 지난 2012년 "국토의 계획 및 이용에 관한 법률"을 개정하였으며, 이를 통해 둘 이상의 용도지역에 걸치는 대지에 대한 용적률 적용기준이 변경되었다. 본 연구는 "국토의 계획 및 이용에 관한 법률" 개정에 따른 용적률 적용기준 변경의 정책적 효과 분석에 대한 연구를 진행하였다. 둘 이상의 용도지역 등에 걸치는 대지라 함은 일반적으로 이해하고 있는 노선상업 또는 노선준주거 지역이다. 본 연구는 노선상업 또는 노선준주거 지역이 상대적으로 많이 입지해있는 서울의 강남구를 대상으로 정책효과를 검증하였다. 이를 위해 2007년부터 2017년까지 강남구에서 거래된 오피스 사례 468건이 분석에 이용되었다. 정책변경에 따른 효과를 검증한 결과 정책변경에 따른 용적률 인센티브를 받은 오피스는 그렇지 않은 오피스에 비해 19.08%의 평당 매매가격 상승이 있는 것으로 나타나 법개정에 따른 경제적 효과가 상당히 컸음을 알 수 있다. 또한 기존 정책이 둘 이상의 용도지역 등에 걸치는 대지의 소유자들의 토지이용에 대한 제약으로 작용했고 이는 곧 해당 자산이 갖고 있는 본연의 가치를 절하요인으로 작용했다고 볼 수 있다. 따라서 본 연구 결과는 정책변경이 둘 이상의 용도지역에 걸쳐있는 토지의 합리적 이용을 이끌어내 해당 자산 본연의 가치를 평가받고 있다는 실증적 근거를 제시했다는데 기여를 했다고 볼 수 있다.

공동주택의 외부공간 시공 후 평가를 통한 생태면적률 개선 방안도출을 위한 기초 연구 - 현장시공시 생태면적률 공간유형 반영을 중심으로 - (A basic study on Improvement for Biotops Area Ratio through the Post Evaluation Plan for Outdoor Space of Apartment Housings)

  • 장대희;김현수;강병근
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.91-96
    • /
    • 2010
  • The problem of urban climate change and destruction of wildlife habitats space which is becoming more serious day by day, has to do with the impervious area(surface area) in urban space. The destruction of natural ground and indiscreet soil covering due to compact development is causing urban desertification in urban residential areas. With biotops area ratio being variously used and extended as a pre planning index, this study aims to analyze the elements of biotop area ratio that need to be supplemented in order to emerge as a realistic planning index for post evaluation measure and not act only as a examining tool in the planning stage. In particular, this study aims to examine the possibility of biotops area ratio to be used as a system to evaluate the outer space of apartment housings, in which biotops area ratio is most actively used, as a tool to secure ecological soundness of the development area after construction is finished.

고강도콘크리트용 내화피복재로 활용하기 위한 경량모르타르의 역학적 성상 (Study on the Mechanical Properties of Lightweight Mortar for Fire Protection Covering Material in High Strength Concrete)

  • 임서형;유석형;문종욱
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.8-13
    • /
    • 2011
  • 고강도 콘크리트는 화재 시 고온에 노출되어 폭렬현상이 발생된다. 폭렬은 철근노출과 함께 구조부재의 단면을 감소시키며, 이로 인하여 구조적 거동에 심각한 문제를 발생시킨다. 본 연구의 목적은 이러한 고강도 콘크리트의 내화피복재로 활용하기 것으로 퍼라이트와 폴리프로필렌 섬유로 경량모르타르를 제조하여 그 역학적 성상을 파악하는데 있다. 이에 따른 실험인자로는 물시멘트비, 골재시멘트비, 폴리프로필렌 섬유 첨가량이다. 연구결과 퍼라이트와 폴리프로필렌 섬유를 첨가함으로서 모르타르의 공극구조를 변화시킬 수 있었으며, 단위중량을 감소시킬 수 있었다. 또한, 고강도 콘크리트의 내화피복재로서 경량모르타르를 사용할 수 있는 가능성을 확인하였다.

표면피복재 종류에 따른 철근콘크리트의 철근 부식특성에 관한 실험적 연구 (An Experimental Study on the Corrosion Characteristics of Reinforcement Concrete According to Types of Surface Covering Material)

  • 김갑수;장종호;김재환;김용로;오시덕;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.39-43
    • /
    • 2003
  • Chloride ions are considered to be the major cause of steel corrosion in concrete structures exposed to seashore environments and also permeation of chloride is controlled by chloride diffusion. Therefore, the study on chloride diffusion of concrete have been done so far by many researchers. It is reported that coating material as surface covering material is effect about deterioration of salt damage and carbonation, therefore these materials are important in durability of concrete structure. In this study, corrosion characteristics of reinforcement concrete according to types of surface covering material were evaluated by water-cement ratio, chloride penetration by age on the corrosion area rate and mass decrement of reinforcement. And it is considered that the result of this study on application of the corrosion characteristics of reinforcements under salt damage environmental will be suggested as fundamental data of control performance of salt damage. It is performed that comparison and examination of control performance of salt damage by the corrosion characteristics under salt damage environmental.

  • PDF

지붕 일체형 태양광 발전 시스템의 응용에 관한 연구 - 시스템의 최적길이비 산정을 중심으로 - (A study on the Application of Roof Integrated Photovoltaic System - Focused on the Optimal Length Ratio Calculation of System -)

  • 김의종;최원기;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.27-33
    • /
    • 2005
  • To improve the performance of the top-positioning space in buildings, we suggested the environment-friendly system integrating various design techniques in the previous paper. This work discussed to calculate the length of PV considering a part of metallic radiators for radiative cooling, an critical element of the whole system, for shading not to prevent the PV on roof from generating electricity. In the process of calculating the shading area, we used the geometrical relationship between the sun-rays and the variable roof. For general applications, we utilized DL, the ratio of the length of PV and that of metallic radiator on roof, as a design factor, and then used the maximum insolation and the specific insolation($200W/m^2$) to decide the distance off the axis of rotation. As a result, for DL, we found out the reasonable value of 1.0 with full covering, 1.2 with 90%, and 2.0 with 70% in PV covering.

과수 방제기용 정전대전 노즐의 분무 및 부착특성 (Spray and Depositional Characteristics of Electrostatic Nozzles for Orchard Sprayers)

  • 강태경;이동현;이채식;이공인;최완규;노수영
    • Journal of Biosystems Engineering
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2004
  • Spraying is one of the most efficient methods for pesticide and insecticide control. Generally, orchard sprayers(aircarrier sprayer) are used for such applications. However, when an orchard sprayer is used, only 20% of total amount of spray deposits on the target. The rest of spray are not only wasted but are also potential sources of environmental pollution. The research far the development of electrostatic spraying system for orchard sprayer was conducted to develop the new pesticide application technology for the reduction of environmental pollution and f3r the production of safe agricultural products. The spray characteristics for nozzles with the different charging methods were tested and the effect of electrostatic charge was analyzed, in the laboratory experiments. The results of this study indicate that the capacitive type of electrostatic spraying nozzle exhibits a large current deposition of water sprays on the sample target. The covering area ratio by conventional spraying system was 10.2%, while that of electrostatic sprays with pulse induction charging method gave the increased covering area ratio by 4.3 times.

도시 열환경을 고려한 녹지관리방안 수립 연구 (A Study on Green Space Management Planning Considering Urban Thermal Environment)

  • 주창훈;김정호;윤용한
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

Two Newly Recorded Ciliates, Oxytricha longigranulosa and o. marina (Ciliophora: Spirotrichea: Sporadotrichida) from Korea

  • Kwon, Choon-Bong;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • 제24권1호
    • /
    • pp.81-88
    • /
    • 2008
  • Two oxytrichid ciliates collected from the mosses and estuarine littoral in Korea were identified as Oxytricha longigranulosa Berger and Foissner, 1989 and O. marina Kahl, 1932. These species are reported for the first time from Korea. The description was based on living and protargol impregnated specimens. Diagnostic characters for each species are as follows. Oxytricha longigranulosa: Cell in vivo $80-115{\times}30-50{\mu}m$, mostly $90{\times}40{\mu}m$. Length/width ratio about 2.4/1. Cortical granules about $1{\times}1.5{\mu}m$ in size, colorless, arranged in short and discontinued longitudinal rows. Four frontoventral cirri. Adoral zone of membrane lies (AZM) covering 30-50% of cell length with 25-27 adoral membranelles (AM). Buccal area flat, typical Oxytricha pattern. Five transverse cirri, 19-23 right marginal cirri, 19-24 left marginal cirri, three caudal cirri, five dorsal kineties. Two macronuclear nodules 2 in number and spherical in shape, two micronuclei in number. Oxytricha marina: Cell in vivo $100-150{\times}30-60{\mu}m$. Cytoplasm colorless without cortical granules. Four frontoventral cirri. AZM covering 50% of cell length with 28-44 AMs, Buccal area flat, typical Oxytricha pattern. Five transverse cirri, 23-38 right marginal cirri, 19-25 left marginal cirri, three caudal cirri, five dorsal kineties. Two macronuclear nodules and spherical in shape, 1-5 micronuclei, mostly two in number.