• Title/Summary/Keyword: Cover ratio

Search Result 574, Processing Time 0.029 seconds

Performance Analysis of NOMA-based Relaying Networks with Transceiver Hardware Impairments

  • Deng, Chao;Zhao, Xiaoya;Zhang, Di;Li, Xingwang;Li, Jingjing;Cavalcante, Charles Casimiro
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4295-4316
    • /
    • 2018
  • In this paper, the performance of non-orthogonal multiple access (NOMA) dual-hop (DH) amplify-and-forward (AF) relaying networks is investigated, where Nakagami-m fading channel is considered. In order to cover more details, in our analysis, the transceiver hardware impairments at source, relay and destination nodes are comprehensively considered. To characterize the effects of hardware impairments brought in NOMA DH AF relaying networks, the analytical closed-form expressions for the exact outage probability and approximate ergodic sum rate are derived. In addition, the asymptotic analysis of the outage probability and ergodic sum rate at high signal-to-noise ratio (SNR) regime are carried out in order to further reveal the insights of the parameters for hardware impairments on the network performance. Simulation results indicate the performance of asymptotic ergodic sum rate are limited by levels of distortion noise.

Seismic Performance of High-Stringth RC Short Columns Confined in Rectangular Steel Tube (강관구속 고강도 철근콘크리트 기둥의 내진성능)

  • 한병찬
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.182-190
    • /
    • 1997
  • A new method to prevent reinforced concrete columns from brittle failure. The method is called transversely reinforcing method in which only the critical regions are confined in steel tube. The steel tubes can change the failure mode of the latter columns from the shear to the flexure. The steel tubes also increase the compressive strength, shear strength and deformation capacity of the infilled concrete. The following conclusions are reached on bases of the study on the seismic performance of the high-strength RC rectangualr short columns confined in steel tube with shear span tho depth ratio of 2.0 The brittle shear failure of high-strength reinforced concrete short columns with large amount of longitudinal bars, which cannot prevented by using the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the concrete inclusive of cover concrete. High-strength RC short columns confined in rectangular steel tube provided excellent enhancement of seismic performance but, found that plastic buckling of the steel tube in the hinge regions tended to occur when the columns were subjected to large cyclic lateral displacements. In order to prevent the plastic buckling when the columns lies on large on cyclic lateral displacements, the steel ribs were used for columns. Tests have established that the columns provide excellent enhancement of seismic performance of inadequately confined columns.

  • PDF

The Use of Water Treatment Sludge as a Landfill Cover Material (정수장(淨水場) 슬러지의 매립장(埋立場) 복토재(覆土材)로의 활용(活用)에 관(關)한 연구(硏究))

  • Lee, Kee-chool;Oh, Joon-seong
    • Clean Technology
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • Dewatered sludge of 400,000t/y from water treatment plants in Korea is being disposed through landfill and ocean dumping. However, the disposal is posing more and more serious environmental problems at the same time not only because of landfill site shortage in municipal suburbs, but because of the concern it will contaminate the oceans. In this study, the research on utilizing the sludge dried by flash dryer as covering soil in the landfill sites was carried out to solve these problems on environmental affinity. Both dewatered and dried sludge were exposed to the natural condition and observed according to the atmospheric changes. An experiment of soil engineering characteristics of the dried sludge and tests on mixed sludge(silty sandy soil : dried sludge = 10:90 ~ 30:70) such as particle size distribution, liquid and plastic limit, moisture content, specific gravity and compaction test were carried out. According to the compaction test, the compaction was confirmed as the optimum water content ratio was observed in the condition of SM-silty sand of particle size distribution, NP of liquid and plastic limit, 101.4% of moisture content, 2.04~2.12 of specific gravity. The results showed that dried sludges mixed with at least 30% of natural soil could be used as daily covering soil in the landfill sites.

  • PDF

Estimation of Precipitation Recharge in the Pyungchang River Basin Using SCS-CN Method (SCS-CN방법을 이용한 평창강 유역의 강수 함양량 선정)

  • Lee Seung Hyun;Bae Sang Keun
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1033-1039
    • /
    • 2004
  • The methodology developed by Soil Conservation Service for determination of runoff value from precipitation is applied to estimate the precipitation recharge in the Pyungchang river basin. Two small areas of the basin are selected for this study. The CN values are determined by considering the type of soil, soil cover and land use with the digital map of 1:25,000. Forest covers more than $94{\%}$ of the study area.. The CN values for the study area vary between 47 in the forest area and 94 in the bare soil under AMC 2 condition. The precipitation recharge rate is calculated for the year when the precipitation data is available since 1990. To obtain the infiltration rate, the index of CN and five day antecedent moisture conditions are applied to each precipitation event during the study period. As a result of estimation, the value of precipitation recharge ratio in the study area vary between $15.2{\%}\;and\;35.7{\%}$ for the total precipitation of the year. The average annual precipitation recharge rate is $26.4{\%}\;and\;26.8{\%}$, meaning 377.9mm/year and 397.5mm/year in each basin.

An Watermarking Method Based on Singular Vector Decomposition and Vector Quantization Using Fuzzy C-Mean Clustering (특이치 분해와 Fuzzy C-Mean(FCM) 군집화를 이용한 벡터양자화에 기반한 워터마킹 방법)

  • Lee, Byung-Hee;Jang, Woo-Seok;Kang, Hwan-Il
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.7
    • /
    • pp.964-969
    • /
    • 2007
  • In this paper, we propose the image watermarking method for good compression ratio and satisfactory image quality of the cover image and the embedding image. This method is based on the singular value decomposition and the vector quantization using fuzzy c-mean clustering. Experimental results show that the embedding image has invisibility and robustness to various serious attacks. The advantage of this watermarking method is that we can achieve both the compression and the watermarking method for the copyright protection simultaneously.

A Study on Classifying Body Forms for the Standards Regarding Size and Grading Method(II) (치수규격 및 그레이딩을 위한 체형 유형화에 관한 연구(II))

  • 권숙희;전은경
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.10
    • /
    • pp.45-51
    • /
    • 2000
  • This study illucidated the importance of drop Value in the resets of surveying the current values of sizing and grading. Therefore, it is meaningful to get the classification of body form with the appropriate distribution of drop values of the body. The distribution of drop value and the frequency of each form is very helpful to name the combined sizing or coverage of ready-made clothes. This study aimed at classifying body forms with various drop values using multivariate analysis for sizing and grading. Factor analysis and cluster analysis were done using measured values from unmarried women. The resets are as follows; The factor which explains body forms was obtained by factor analysis, and the representative major 18 items which have important roles in classifying body forms were selected among the measured values with high factor loading and communality. 1) The body forms were classified into 3 groups based on the characteristics, frequencies and distributions of them obtained from cluster analysis. 2) Each classified body form showed conspicuous difference in drop value and the difference of body form mainly resulted from the difference between bust and hip(drop value) in Korean unmarried women. 3) Discriminant analysis showed that the most significant discriminant factor of the trunk classification were bust circumference, upper bust circumference, hip circumference and stature. 4) The cover ratio of size studied in this study for the Korean Sizing system for women's garment were founded high.

  • PDF

Current Limit Strategy of Voltage Controller of Delta-Connected H-Bridge STATCOM under Unbalanced Voltage Drop

  • Son, Gum Tae;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.550-558
    • /
    • 2018
  • This paper presents the current limit strategy of voltage controller of delta-connected H-bridge static synchronous compensator (STATCOM) under an unbalanced voltage fault event. When phase to ground fault happens, the feasibility to heighten the magnitude of sagging phase voltage is considered by using symmetric transformation method in delta-structure STATCOM. And the efficiency to cover the maximum physical current limit of switching device is considered by using vector analysis method that calculate the zero sequence current for balancing the cluster energy in delta connected H-bridge STATCOM. The result is simple and obvious. Only positive sequence current has to be used to support the unbalanced voltage sag. Although the relationship between combination of the negative sequence voltage with current and zero sequence current is nonlinear, the more negative sequence current is supplying, the larger zero sequence current is required. From the full-model STATCOM system simulation, zero sequence current demand is identified according to a ratio of positive and negative sequence compensating current. When only positive sequence current support voltage sag, the least zero sequence current is needed.

A Study for Development of Durability of the Subway Concrete Structure exposed to Choride Environment (염해 환경에 있는 지하철 콘크리트 구조물의 내구성 향상 대책수립에 관한 연구)

  • Lee Moo-Kwan;Kim Eun Kyum;Kim Dae Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1184-1189
    • /
    • 2005
  • Durability of concrete has been currently issued in the engineering societies and a large number of studies on the concrete corrosion in salty environment have been performed. The reinforcement corrosion, which is the primary reason of deterioration of the concrete structure exposed to chloride environment. is caused by the chloride ions infiltration owing to underground water seeping into the concrete. In this study. the endurance periods using the diffusion equation of the concrete specification have been evaluated on the concrete structures with different addictives for the brand new R/C subway structure exposed to seashore underground water. Furthermore. the guidance for proper use of the addictives and the reasonable thickness of concrete cover are derived for concrete mixing. From the result of the evaluation corresponding to salt damage for Inchon subway line I, the endurance periods of the ordinary Portlandcement concretes are represented as $42\~75$ years and fail to achieve the objective period of 100 years. However, the lower water-cement ratio expands the endurance periods and the blast furnace slag concrete with small quantity of the silica fume, which shows the best performance of corrosion resistance in this study, represents more than 170 years of the endurance period. Moreover, the case of use of blast furnace slag and fly ash together shows the endurance period of $134\~171$ years and it means that the result very satisfies the objective endurance period.

  • PDF

An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots (성능선도에 의한 다통로 판형열교환기의 간이설계법)

  • 유호선;이근휘;방보청
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

Design and Implementation of Multiband Internal Antenna for LTE Mobile Handset

  • Cho, Young Min;Jung, Pil Hyun;Yang, Woon Geun
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.124-132
    • /
    • 2015
  • In this paper, we proposed a multiband internal antenna for LTE mobile handset that could be used for mobile devices. The proposed antenna has a volume of $50mm(W){\times}21mm(L){\times}5mm(H)$, ground plane size is $60mm(W){\times}100mm(L)$, and covers 9 service frequency bands including LTE(Long Term Evolution) band with VSWR(Vlotage Standing Wave Ratio) less than 3. With rapid change of technologies, people wants to include more function into one device. In addition, each country uses different frequency band for traffic service, it is necessary to design multiband antenna for mobile phone since traveling foreign country needs roaming. And if we can cover several services with one antenna, cost and volume needed for antennas are minimized. A HFSS (High Frequency Structure Simulator) of the Ansoft Corporation based on a finite element method is employed to analyze the proposed antenna in the design process and to compare the simulation and experimental results.