• Title/Summary/Keyword: Cover Depth

Search Result 430, Processing Time 0.022 seconds

Repid Corrosion Test on Reinforcing Steels in Chloride-Penetrating Concrete Structures with Various Crack Patterns (균열특성에 따른 콘크리트 구조물의 염분침투에 관한 실험적 연구)

  • 이상국;정영수;문홍식;안태송;유환구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.345-350
    • /
    • 2001
  • Reinforced concrete is, in general, known as a high durability material due to a strong alkalinity of cement. Probable concrete cracks could incur steel corrosion of RC structures and then could easily deteriorate the concrete durability, which can be fully secured by a systematic quality control for the construction of concrete structures. For the corrosion protection of reinforcing steels in concrete, however, current design specifications of concrete cover depth do not in-depth consider the effect of the cracks as well as the chloride content of RC structures. Therefore, appropriate provisions for concrete cover depth should be coded by considering the influence of concrete cracks on the corrosion of reinforcing steels. The objective of this research is to investigate pertinent cover depth, which can prohibit rebar corrosion, on the basis of experimental corrosion measurements of reinforcing steels on crack characteristics such as the width, depth and frequency of concrete cracks.

  • PDF

Extraction of Snowmelt Parameters using NOAA AVHRR and GIS Technique for 5 River Basins in South Korea (NOAA AVHRR 영상 및 GIS 기법을 이용한 국내 5대강 유역의 융설 매개변수 추출)

  • Shin, Hyung-Jin;Park, Geun-Ae;Kim, Seong-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.119-124
    • /
    • 2007
  • The few observed data related snowmelt was the major cause of difficulty in extracting snowmelt factors such as snow cover area, snow depth and depletion curve. Remote sensing technology is very effective to observe a wide area. Although many researchers have used remote sensing for snow observation, there were a few discussions on the characteristics of spatial and temporal variation. Snow cover maps were derived from NOAA AVHRR images for the winter seasons from 1997 to 2006. Distributed snow depth was mapped by overlapping between snow cover maps and interpolated snowfall maps from 69 meteorological observation stations. Model parameters (Snow Cover Area: SCA, snow depth, Snow cover Depletion Curve: SDC) building for 5 major watersheds in South Korea. Especially SDC is important parameter of snowmelt model.

Comparison of Snow Cover Fraction Functions to Estimate Snow Depth of South Korea from MODIS Imagery

  • Kim, Daeseong;Jung, Hyung-Sup;Kim, Jeong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.4
    • /
    • pp.401-410
    • /
    • 2017
  • Estimation of snow depth using optical image is conducted by using correlation with Snow Cover Fraction (SCF). Various algorithms have been proposed for the estimation of snow cover fraction based on Normalized Difference Snow Index (NDSI). In this study we tested linear, quadratic, and exponential equations for the generation of snow cover fraction maps using data from the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua satellite in order to evaluate their applicability to the complex terrain of South Korea and to search for improvements to the estimation of snow depth on this landscape. The results were validated by comparison with in-situ snowfall data from weather stations, with Root Mean Square Error (RMSE) calculated as 3.43, 2.37, and 3.99 cm for the linear, quadratic, and exponential approaches, respectively. Although quadratic results showed the best RMSE, this was due to the limitations of the data used in the study; there are few number of in-situ data recorded on the station at the time of image acquisition and even the data is mostly recorded on low snowfall. So, we conclude that linear-based algorithms are better suited for use in South Korea. However, in the case of using the linear equation, the SCF with a negative value can be calculated, so it should be corrected. Since the coefficients of the equation are not optimized for this area, further regression analysis is needed. In addition, if more variables such as Normalized Difference Vegetation Index (NDVI), land cover, etc. are considered, it could be possible that estimation of national-scale snow depth with higher accuracy.

Self-terminated carbonation model as an useful support for durable concrete structure designing

  • Woyciechowski, Piotr P.;Sokolowska, Joanna J.
    • Structural Engineering and Mechanics
    • /
    • v.63 no.1
    • /
    • pp.55-64
    • /
    • 2017
  • The paper concerns concrete carbonation, the phenomena that occurs in every type of climate, especially in urban-industrial areas. In European Standards, including Eurocode (EC) for concrete structures the demanded durability of construction located in the conditions of the carbonation threat is mainly assured by the selection of suitable thickness of reinforcement cover. According to EC0 and EC2, the thickness of the cover in the particular class of exposure depends on the structural class/category and concrete compressive strength class which is determined by cement content and water-cement ratio (thus the quantitative composition) but it is not differentiated for various cements, nor additives (i.e., qualitative composition), nor technological types of concrete. As a consequence the selected thickness of concrete cover is in fact a far estimation - sometimes too exaggerated (too safe or too risky). The paper presents the elaborated "self-terminated carbonation model" that includes abovementioned factors and enables to indicate the maximal possible depth of carbonation. This is possible because presented model is a hyperbolic function of carbonation depth in time (the other models published in the literature use the parabolic function that theoretically assume the infinite increase of carbonation depth value). The paper discusses the presented model in comparison to other models published in the literature, moreover it contains the algorithm of concrete cover design with use of the model as well as an example of calculation of the cover thickness.

Field Research for the Durability Assessment Factor for deriving the Carbonation of Concrete Bridges in the Marine Environment (해양 환경하 콘크리트 교량의 탄산화 내구성능 평가 인자 도출을 위한 현장조사 연구)

  • Chai, Won-Kyu;Lee, Myeong-Gu;Son, Young-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.102-109
    • /
    • 2015
  • In this study, on the basis of the results of the field survey and the theoretical consideration for Korean Standard Specification for concrete durability and maintenance, the following conclusions are derived. From the survey, the prediction equation of carbonation depth for the southwest region in Korea is experimentally proposed, $y_p=5.865{\sqrt{t}}$, which predicts about 60mm of the carbonation depth for the concrete structures of 100 years, a 1st class of target endurance period, under a combined deterioration environment like a marine environment. Considering that the marginal value for a carbonation depth limitation under very severely marine environment is 25mm, in accordance with the Specification, it is found that the predicting carbonation depth for the concrete cover depths, 100mm and 60mm are 63mm and 29.4mm, respectively. In conclusion, according to the equation and the Specification, it is strongly required that the reinforced concrete structures with the cover depth under 100mm have to make a protection from combined deterioration factors by any methods like a surface coating, an increment of cover depth or an application of a special concrete.

Service Life Variation for RC Structure under Carbonation Considering Korean Design Standard and Design Cover Depth (국내설계기준과 피복두께를 고려한 RC 구조물의 탄산화 내구수명의 변동성)

  • Kim, Yun-Shik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.15-23
    • /
    • 2021
  • In this paper, service life for RC(Reinforced Concrete) substructure subjective to carbonation was evaluated through deterministic and probabilistic method considering field investigation data and Design Code(KDS 14 20 40). Furthermore changes in service life with increasing COV(Coefficient of Variation) and equivalent safety index meeting the same service life were studied. From the investigation, the mean and its COV of cover depth were evaluated to 70.0 ~ 90.0 mm and 0.2, respectively. With intended failure probability of 10.0 % and 70 mm of cover depth, service life decreased to 137 years, 123 years, and 91 years with increasing COV of 0.05, 0.1, and 0.2, respectively. In the case of 80 mm of cover depth, it changes to 179 years, 161 years, and 120 years with increasing COV. The equivalent safety index meeting the same service life from deterministic method showed 1.66 ~ 3.43 for 70 mm of cover depth and 1.61 ~ 3.24 for 80 mm of cover depth, respectively. The various design parameters covering local environment and quality condition in deterministic method yields a considerable difference of service life, so that determination of design parameters are required for exposure conditions and parameter variation.

Relationship between Corrosion in Reinforcement and Influencing Factors Using Half Cell Potential Under Saturated Condition (습윤 상태에서의 반전위를 이용한 철근 부식과 영향 인자 간의 상관성 분석)

  • Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • In this study, the correlation between the influencing factors on corrosion and Half Cell Potential(HCP) measurement was analyzed considering the three levels of W/C ratio, cover depth, and chloride concentration. The HCP increased with enlarged cover depth, so it was confirmed that the increment of cover depth was effective for control of corrosion. Based on the criteria, the case of 60mm cover depth showed excellent corrosion control with under -200mV, indicating increase of cover depth is an effective method for reducing intrusion of external deterioration factors. When fresh water was injected to the upper part of specimens, very low level of HCP was monitored, but in the case that concentrations of chloride were 3.5% and 7.0%, HCP dropped under -200mV. In addition, the case with high volume of unit binder showed lower HCP measurement like increasing cover depth. Multiple regression analysis was performed to evaluate the correlation between the corrosive influence factors and HCP results, showing high coefficient of determination of 0.97. However, there were limitations such as limited number of samples and measuring period. Through the additional corrosion monitoring and chloride content evaluation after dismantling the specimen, more reasonable prediction can be achieved for correlation analysis with relevant data.

Probabilistic service life of box culvert due to carbonation of concrete cover

  • Woo, Sang-Kyun;Chu, In-Yeop;Lee, Yun;Lee, Byung-Jae
    • Advances in concrete construction
    • /
    • v.12 no.6
    • /
    • pp.517-525
    • /
    • 2021
  • More underground structures are increasingly being constructed such as box culverts for electric power transmission, and the life extension of these structures is very important. It is well known that the steel embedded in concrete is usually invulnerable to corrosion because the high alkalinity of the pore solution in concrete generates a thin protective oxide layer on the surface of the steel. Recent observations in the field and experimental evidence have shown that even steel in concrete can be corroded through the carbonation reaction of cover concrete. Carbonation-induced corrosion in concrete may often occur in a high carbon dioxide environment. In this study, the risk of carbonation of underground box culverts in Korea was evaluated by measuring the car¬bonation rate and concrete cover depth in the field. Then, the carbonation-free service life for the cover depth of the steel was calcu¬lated with in situ information and Monte Carlo simulation. Additionally, an accelerated carbonation test for a cracked beam specimen was performed, and the effect of a crack on the service life of a box culvert was numerically investigated with Monte Carlo simulation based on experimental results.

Studies on Growth Characteristics and Shallow Green-Roof Systems of Sedum album L. Introduced in Korea (국내에 도입된 Sedum album L.의 생육 특성 및 저토심 옥상 녹화 시스템에 관한 연구)

  • Kim In-Hye;Huh Moo-Ryong;Huh Keun-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.5 s.112
    • /
    • pp.69-82
    • /
    • 2005
  • These studies were carried out (1) to investigate the growth characteristics of Sedum album L. in the field, (2) to propose a suitable shallow peen roof system for this plant, and (3) to evaluate plant growth in the proposed system over the long term. The growth characteristics, such as morphological properties, growth habit, shade tolerance, and flowering, were surveyed. In experimental shallow green-roof systems, the effects of drainage type, substrate type, and soil depth on plant growth were investigated. Then drought tolerance was investigated. After planting Sedum album L. in the proposed system survival rate, cover, and resistance to insects, heal and cold were evaluated for about 2 years. The results of these studies are summarized below. 1. In the field, the aboveground part of Sedum album L. did not die back during the winter. Plant height was 4$\sim$7 cm. Roots were distributed to a depth of 5$\sim$7 cm. Sedum album L. is a compact ground-cover plant that spreads vigorously. Shading condition of less than $30\%$ of full sunlight didn't cause any trouble, but shading conditions above $87\%$ made the shape of the shoots and leaves abnormal. The plant bloomed from June to August and had a rather large compound umbel of white, star-shaped flowers. 2. Two systems, a drainage-blend-10 cm soil depth and a reservoir$\cdot$drainage-blend-15 cm soil depth, performed best in terms of cover, fresh weight, and dry weight. The first has an advantage for green roofs because it is lighter than the latter. 3. In drainage-blend-10 m soil depth and modified reservoir · drainage-blend-10 cm soil depth system no plants died for about 4 months after stopping the irrigation. The visual quality of the latter system was above 5 for 4 months and that of the former was under 5 after 2 months. In the field, however, the drought tolerance of Sedum album L. grown in the former would be enough to withstand the dry season. Considering the urban ecosystem and the importance of healthy growth the modified reservoir $\cdot$ drainage-blend-10 cm soil depth system was finally recommended. This system was composed of a 4 cm thick drainage layer and drain outlets placed at a height of 2.5 cm. 4. In the proposed system, the survival rate was $100\%$, and there was no injury induced by insects and heat. The leaf density decreased a little in winter. Cover increased throughout the year. Sedum album L. was planted with a cover of 72$cm^{2}$ on 3 April 2003; on 16 June 2003 and 15 June 2004, cover was $132.66\pm$5.87 $cm^{2}$(1.8 times) and $886.98\pm$63.51 $cm^{2}$(12.3 times), respectively.

A Preliminary Study on the Corrosion Monitoring Sensor of Chloride Permeation into Concrete (콘크리트내 염분침투 모니터링을 위한 부식 센서 개발에 관한 기초적 연구)

  • Joh, Sung-Hyung;Lee, Hyun-Seok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.5-7
    • /
    • 2010
  • Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored in cover concrete of reinforced concrete structures. For making sensor which is similar to rebar author uses Screen printer machines, Ag paste and Fe powder. Appropriate portion of Ag and Fe is over 1:2. The resistance of sensors increased as the degree of corrosion increased. And according to cover depth author suggests sensor system which has a demanded cover depth. It was therefore confirmed that the corrosion sensor can monitor chloride permeation by change of resistance.

  • PDF