• Title/Summary/Keyword: Coupled-Feed

Search Result 138, Processing Time 0.026 seconds

Complete genome sequence of Paenibacillus konkukensis sp. nov. SK3146 as a potential probiotic strain

  • Jung, Hae-In;Park, Sungkwon;Niu, Kai-Min;Lee, Sang-Won;Kothari, Damini;Yi, Kwon Jung;Kim, Soo-Ki
    • Journal of Animal Science and Technology
    • /
    • v.63 no.3
    • /
    • pp.666-670
    • /
    • 2021
  • Paenibacillus konkukensis sp. nov., SK3146 is a novel strain isolated from a pig feed. Here, we present complete genome sequence of SK3146. The genome consists of a single circular genome measuring 7,968,964 bp in size with an average guanine + cytosine (G+C) content of 53.4%. Genomic annotation revealed that the strain encodes 151 proteins related to hydrolases (EC3), which was higher than those in Bacillus subtilis and Escherichia coli. Diverse kinds of hydrolases including galactosidase, glucosidase, cellulase, lipase, xylanase, and protease were found in the genome of SK3146, coupled with one bacteriocin encoding gene. The complete genome sequence of P. konkukensis SK3146 indicates the immense probiotic potential of the strain with nutrient digestibility and antimicrobial activity functions.

Profile Position Control of Extractive Thermally Coupled Distillation System (추출 열 통합 증류계의 프로필 위치 제어)

  • Cho, Hoon;Choi, Yu-Mi;Lee, Jin-Hong;Cho, Im-Pyo;Han, Myung-Wan
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.815-824
    • /
    • 2012
  • Extractive distillation system can be used when the components to be separated have close boiling points or form azeotropes. Extractive distillation is one of the most important and widely used separation methods in chemical process industry. The main disadvantage of the distillation is its high-energy requirements. Thermally coupled distillation system (TCDS) can provide significant savings in energy consumption and capital cost over the operation of sequences based on conventional distillation column. Despite such advantages of the thermally coupled distillation system, the process is not widely used in industry because control and operation of the column are difficult. In this study, we propose several control schemes for thermally coupled distillation system to overcome the difficulties and make the column stable when the process is confronted with feed disturbances. Profile position control scheme shows best control performance among the proposed control schemes.

Study on the Characteristics of Turbopump+Gas generator Closed-loop coupled test (터보펌프+가스발생기 폐회로 연계시험 특성 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.38-41
    • /
    • 2009
  • For the technology development of LOx/kerosene liquid rocket engine, turbopump-gas generator closed-loop coupled tests using 30tonf main engine components such as turbopump and gas generator except combustion chamber are performed. In the engine system operation environment, simulating combustion chamber by flow control units, the chill-down procedure, startup characteristics, nominal operability and smooth shutdown of turbopump+gas generator closed-loop coupled Test Plant are successfully confirmed. The serviceability of the turbopump and gas generator are evaluated. The feed-back control system for the turbopump rotational speed and gas generator mixture ratio are also verified. The results of closed-loop coupled test will be used as the technology development for the liquid rocket engine.

  • PDF

Iterative Feed-forward Control of Shaking Table System Based on FRF of Hydraulic Actuator (유압 서보 구동기의 동특성을 고려한 진동 시험기의 반복 피드포워드 제어)

  • Lee, Dong-Jae;Park, Young-Jin;Park, Youn-Sik;Kim, Hyoung-Eui;Park, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.556-560
    • /
    • 2007
  • In this paper, the research results for the improvement of tracking performance of a hydraulic shaking table are presented. A servo-hydraulic shaking table is not only highly nonlinear but also has a lot of time delay. In addition, the shaking table, which consists of multi axial hydraulic actuators, is a MIMO system coupled by kinematics and dynamics of each other's actuators. And it is demanded for the shaking table to track arbitrary trajectories up to high frequency even at the extreme situations such as substantial external loads and large disturbances. For this purpose, an iterative feed-forward control based on the inverse of a measured frequency response function is used for the shaking table. To solve the dynamic coupling, a pressure feedback control as numerical damping is used. It is shown through numerical simulations that the tracking performance of shaking table is improved up to 100Hz.

  • PDF

Design of Three-elements CRPA Arrays Using Improved Low-elevation Gain (저고도각 고이득 특성을 이용한 3 소자 CRPA 배열 안테나 설계)

  • Yoo, Sungjun;Byun, Gangil;Lee, Jun-yong;Choo, Hosung
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • In this paper, we propose a three-element CRPA array with improved low-elevation gain. The proposed antenna consists of a feed patch and a radiating patch, and the feed patch is connected by a coaxial cable. The radiating patch is electromagnetically coupled to the feed patch, which allows to improve the low-elevation gain of the antenna. To demonstrate the suitability of the proposed antenna, the antenna characteristics are measured in a full anechoic chamber. The resulting bore-sight gain is 2.8 dBic with an axial ratio of 2.7 dB, and the average gain at the low-elevation direction of $75^{\circ}$ is -1.4 dBic. The results verify that the proposed antenna is suitable for CRPA arrays with anti-jamming capability.

Theory and Experiment of the Cylindrical Edge-Slot Antenna with Coaxial Line Feed (동축선로로 급전된 원통형 에지-슬롯 안테나의 이론 및 실험)

  • 유상기;홍재표;조영기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.39-44
    • /
    • 1994
  • A theoretical method has been considered for the analysis of a cylindrical edge-slot antenna which belongs to a class of circumferential slot antennas that are suitable for conformal mounting on conducting bodies of revolution. A coupled integral equation is formulated for unknown magnetic currents of both the coaxial aperture and the edge slot, and solved by the moment method. Theoretical values for reflection coefficient obtained based upon the method are compared with our experimental values and other author's results available. There arre good agreement between them.

  • PDF

A printed coupled-feed WLAN antenna (인쇄형 결합급전 무선랜 안테나)

  • Chae Gyoo-Soo;Lim Joong-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.203-205
    • /
    • 2004
  • 본 논문에서는 휴대용 무선기기에 응용 될 수 있는 이중대역 무선랜 안테나가 소개되었다. 소개된 디자인은 두개의 방사부를 가지는 1/4파장 안테나를 모델로 개발되었다. 수치해석 결과에 따라 견본안테나가 제작되었고 최적의 특성을 얻기 위해 몇 번의 수정을 거친 후에 본 논문에서 제안된 안테나가 제작되었다. 본 논문에서 제안된 안테나는 2.4/5GH 주파수 대역에서 동작하고 주로 노트북PC에 장착되어 사용 될 수 있다. 제시된 모든 결과들은 실제 실험용 노트북PC에 장착된 상태에서 얻어진 것이다.

  • PDF

Residue of Harmful Heavy Metals in Swine Tissue and Feedstuff (돈육 및 양돈사료중 유해중금속의 잔류량 조사)

  • 조태행;정갑수;손성완;박종명;박근식
    • Journal of Food Hygiene and Safety
    • /
    • v.2 no.3
    • /
    • pp.103-108
    • /
    • 1987
  • ABSTRACT-The study was to investigate the residue of the harmful heavy metals in the random samples of feed from piggery, formula feeed for swine and ingredient feed from feed mill and analyzed for Cd, Pb and As by using Atomic Absorption Spectrophotometer and Inductively Coupled Argon Plasmas. Mean concentrations of Cd, Pb and As (ppm) were, for feed from piggery 1.08-0.85, 5.34-4.29 and 4.30-2.37, for formula feed from feed mill, 0.90-0.51, 5.84-5.25 and 2.41-0.84, and for ingredient feed from feed mill, 0.35-0.38, 4.38-4.94 and 2.66-1.12, respectively. It showed the highest amount of Cd, Pb and As in kidney and liver than in the other organs, and the lowest amount in the muscle.muscle.

  • PDF

Mecrostrip Array Antenna Directly Coupled to E-Plane (E-면으로 직접 결합된 마이크로스트립 어레이 안테나)

  • Kim, Tae-Hyung;Hong, Jae-Pyo;Pak, Chin-Taek;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.23-29
    • /
    • 1991
  • In order to improve the radiation characteristics of the microstrip antenna, microstrip array antenna consisting of one center patch fed by a coaxial probe and several patches directly coupled to the E-plane by microstrip line is analyzed. The equivalent circuit of the array antenna is represented by the conventional transmission line and the various parameters, such as the mdicrostrip line length, the patch length and the feed point location are calculated to improve the radiation pattern for 5-patch array antenna which has the equal patch width. The 5-patch array antenna with the radiation pattern which has low sidelobe level and narrow beam width is fabricated and then the measured results are compared with the computed values and the results of the single patch microstrip antenna too.

  • PDF