• 제목/요약/키워드: Coupled magnetic resonance system

검색결과 28건 처리시간 0.027초

A Novel Impedance Matching Topology for Magnetically Coupled Wireless Power Transfer

  • Lee, Gunbok;Park, Wee Sang
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.16-19
    • /
    • 2012
  • A modified 4-coil magnetic resonance wireless power transfer (MRWPT) system is proposed. Four coils based on 2-coil system with additional two matching coils were used in this topology. When Tx-Rx distance is changed, the input impedance is changed. However, it can be adjusted by coil parameters of matching coils to maintain impedance matching for maximum efficiency. The equivalent circuit of MRWPT system was analyzed for both transmission function and optimum coupling coefficient of the matching coils. By using four spiral resonant coils, these design considerations was experimentally verified. The measured data agreed well with the calculated data and the transmission function of the proposed system was more efficient than that of conventional 2-coil system.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

Wireless Synchronous Transfer of Power and Reverse Signals

  • Li, Yang;Li, Yumei;Feng, Shaojie;Yang, Qingxin;Dong, Weihao;Zhao, Jingtai;Xue, Ming
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.827-834
    • /
    • 2019
  • Wireless power transfer via coupled magnetic resonances has been a hot research topic in recent years. In addition, the number of related devices has also been increasing. However, reverse signals transfer is often required in addition to wireless power transfer. The structure of the circuit for a wireless power transfer system via coupled magnetic resonances is analyzed. The advantages and disadvantages of both parallel compensation and series compensation are listed. Then the compensation characteristics of the inductor, capacitor and resistor were studied and an appropriate compensation method was selected. The reverse signals can be transferred by controlling the compensation of the resistor. In addition, it can be demodulated by extracting the change of the primary current. A 3.3 MHz resonant frequency with a 100 kHz reverse signals transfer system platform was established in the laboratory. Experimental results demonstrate that wireless power and reverse signals can be transferred synchronously.

Determination of a Weak Exchange Interaction in Magnetically Coupled Cluster System by EPR Singlet-Triplet Transition Lines

  • Cho, Young-Hwan;Hyunsoo So
    • 한국자기공명학회:학술대회논문집
    • /
    • 한국자기공명학회 2002년도 International Symposium on Magnetic Resonance
    • /
    • pp.70-71
    • /
    • 2002
  • Exchange-coupled cluster of transition-metal ions are relevant to many different scientific areas, ranging from chemistry to solid-state physics, biology, material science and has been the subject of much research in recent years(1,2). Single crystal EPR spectroscopy works as a very effective tool for the measurement of J values for small exchange interactions. This makes EPR technique very suitable for detection of weak exchange coupling transmitted over long distances via extended atomic and melecular bridges. Large polyoxometallates (3) may provide ideal structural environments for the study of interactions between paramagnetic ions. The detailed nature of magnetic interaction (positive sign and magnitude of J~0.006 $cm^{-1}$ /) was clearly determined for di-copper(II) system by single crystal EPR spectroscopy (4). The single-triplet (S-T) transitions are forbidden by different symmetries of the wave functions. However, when the singlet ground state is mixed into triplet states, the S-T transitions can be allowed and observed as weak lines. These weak S-T lines are positioned symmetrically with respect to the main transitions in the distance equals to 2J from the center of the spectrum. This lines allow one to determine the J-value with very high accuracy when │J│ < hv 0.32 $cm^{-1}$ /. Unfortunately, the S-T transitions in the single crystal were detected by EPR method only in a few complexes until now. We have measured single-triplet transition lines for several magnetically coupled cluster systems and determined their J values accurately. The temperature dependency of J was studied by monitoring the changes in S-T.

  • PDF

Wireless Energy Transfer System with Multiple Coils via Coupled Magnetic Resonances

  • Cheon, Sanghoon;Kim, Yong-Hae;Kang, Seung-Youl;Lee, Myung Lae;Zyung, Taehyoung
    • ETRI Journal
    • /
    • 제34권4호
    • /
    • pp.527-535
    • /
    • 2012
  • A general equivalent circuit model is developed for a wireless energy transfer system composed of multiple coils via coupled magnetic resonances. To verify the developed model, four types of wireless energy transfer systems are fabricated, measured, and compared with simulation results. To model a system composed of n-coils, node equations are built in the form of an n-by-n matrix, and the equivalent circuit model is established using an electric design automation tool. Using the model, we can simulate systems with multiple coils, power sources, and loads. Moreover, coupling constants are extracted as a function of the distance between two coils, and we can predict the characteristics of a system having coils at an arbitrary location. We fabricate four types of systems with relay coils, two operating frequencies, two power sources, and the function of characteristic impedance conversion. We measure the characteristics of all systems and compare them with the simulation results. The flexibility of the developed model enables us to design and optimize a complicated system consisting of many coils.

Identification of Xanthium Sibiricum Components using LC-SPE-NMR-MS Hyphenated System

  • Sohn, Ji Soo;Jung, Youngae;Han, Ji Soo;Hwang, Geum-Sook
    • 한국자기공명학회논문지
    • /
    • 제22권2호
    • /
    • pp.26-33
    • /
    • 2018
  • Xanthium sibiricum is used as a traditional folk medicine for the treatment of cancer, fever, headache, nasal sinusitis, and skin pruritus. This study aimed to identify components from Xanthium sibiricum extracts using an SPE-800MHz NMR-MS hyphenated system. The simultaneous acquisition of MS and NMR spectra from the same chromatographic peaks significantly increases the depth of information acquired for the compound and allows the elucidation of structures that would not be possible using MS or NMR data alone. LC -NMR analysis was conducted using a HPLC separation system coupled to 800 MHz spectrometer equipped with a cryoprobe, and a SPE unit was used to automatically trap chromatographic peaks using a HPLC pump. LC-MS analysis was conducted with a Q-TOF MS instrument using ESI ionization in the negative ion mode. Using the hyphenated analysis, several secondary metabolites were identified, such as 3',5'-O-dicaffeoylquinic acid, 1',5'-O-dicaffeoyl- quinic acid, and ethyl caffeate. These results demonstrate that the SPE-800MHz NMR-MS hyphenated system can be used to identify metabolites within natural products that have complex mixtures.

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권4호
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

결합된 자기공명을 통한 무선에너지 전력 전송 시스템의 회로 해석

  • 전상훈;김용해;이명래;강승열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.405-407
    • /
    • 2010
  • Simple equivalent circuit model is developed for wireless energy transfer system via coupled magnetic resonances and practical design method is also provided. Node equations for the resonance system are built with the method expanding transformer's equations and the optimum distances of coils in the system is derived analytically for optimum coupling coefficients for high transfer efficiency. Moreover, to calculate the frequency characteristics for a lossy system the equivalent model is established at an electric design automation tool. The model parameters of the actual system are extracted and the results of modeling are compared with the measurement. Through the developed model, we can understand the principles that the system shows higher efficiency than conventional magnetic coupling systems and impedance matching is important to achieve high efficiency.

  • PDF

디스크 드라이브 스핀들 계의 동특성 해석 프로그램 (Dynamic Analysis Program for Disk Drive Spindle Systems)

  • 오동호;김철순;박노열;노광춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.211-217
    • /
    • 1998
  • A disk rotor dynamic analysis program called by DR. DAP is developed for disk drive spindle systems to analyze dynamic characteristics in operation and to estimate the effects of excitation sources. It is applicable to design for stabilization and to select parts of disk drive spindle systems. The disk drive spindle system in this program is modeled as a flexible shaft with multiple flexible disks, which is supported by bearings and driven by electric motor, and its complicated coupled vibration characteristics are analyzed by using a substructure synthesis technique with the assumed-modes method. All the coupled modes of interest can be well predicted by the example of a three disk hard disk drive with the three tuning parameters. It is also shown that, with the introduction of the excitation sources associated with the defects of ball bearing systems, the magnetic unbalance of spindle motor, the program can well predict the stability of the system, i.e., the possibility of resonance.

  • PDF

Time-Domain Analysis of Wireless Power Transfer System Behavior Based on Coupled-Mode Theory

  • Shim, Hyunjin;Nam, Sangwook;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제16권4호
    • /
    • pp.219-224
    • /
    • 2016
  • In this paper, coupled-mode theory (CMT) is used to obtain a transient solution analytically for a wireless power transfer system (WPTS) when unit energy is applied to one of two resonators. The solutions are compared with those obtained using equivalent circuit-based analysis. The time-domain CMT is accurate only when resonant coils are weakly coupled and have large quality factors, and the reason for this inaccuracy is outlined. Even though the time-domain CMT solution does not describe the WPTS behavior precisely, it is accurate enough to allow for an understanding of the mechanism of energy exchange between two resonators qualitatively. Based on the time-domain CMT solution, the critical coupling coefficient is derived and a criterion is suggested for distinguishing inductive coupling and magnetic resonance coupling of the WPTS.