• Title/Summary/Keyword: Coupled channel analysis

Search Result 68, Processing Time 0.025 seconds

Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System (2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析))

  • Kim, Y.D.;Min, M.K.;Lee, S.H.;Kim, W.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

Dielectric Waveguide Channel Dropping Filter (유전체 도파관을 이용한 채널 드로핑 필터)

  • 김신기;박동철;오승엽
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 1988
  • A new type broadband channel dropping filter which has a potential use as a millimeter-wave multiplexer has been realized by properly connecting 3-dB directional couplers and bandstop filters. 90\ulcorner3-dB directional couplers have been designed using two nonuniformly coupled dielectric image guides, while bandstop filters with Chebyshev passbands have been designed using dielectric image-guide grating structure. Effective dielectric constant method has been aplied to the image-guide dispersion analysis and to the design of bandstop gratings and 3-dB couplers. Experimental results in excellent agreement with computed responses are demonstrated.

  • PDF

Coupled Operation of the Lake Youngsan and Yeongam for the Flood Control in the Downstream of the Youngsan River (영산강 하류부 홍수조절을 위한 영산호-영암호 연계운영 방안)

  • Kim, Dae Geun;Lee, Jae Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.297-306
    • /
    • 2008
  • In order to determine the effects of lock gate expansion at the Lake Youngsan and Yeongam as well as increase in the width of the connecting channel of the two lakes on flood control downstream of the Youngsan River, an unsteady hydraulic flood routing was conducted by combining the Lake Youngsan and Yeongam as a single connected system. The coupled operation of the two lakes was found to have little effect when the widths of the lock gates and the connecting channel are set at the current level. It was also found that increasing the width of the connecting channel as well as the lock gate of the Lake Yeongam is an effective means of reducing the stage of the Lake Youngsan, whereas an increase in the width of the Lake Youngsan's lock gate had a relatively smaller effect. The extended width of the connecting channel leads to a rise in the stage of the Lake Yeongam. In order to reduce the elevated stage, The Lake Yeongam's lock gate must be expanded along with the Lake Yeongsan's lock gate. The analysis found that the stage of the Lake Yeongsan can be effectively controlled through adjustment of opening and shutting criteria of the connecting channel's lock gate, when diversion discharge between the lakes is increased as a result of expanding the width of the connecting channel.

Determination of the Depletion Depth of the Deep Depletion Charge-Coupled Devices

  • Kim Man-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.233-236
    • /
    • 2006
  • A 3-D numerical simulation of a buried-channel CCD (Charge Coupled Device) with a deep depletion has been performed to investigate its electrical and physical behaviors. Results are presented for a deep depletion CCD (EEV CCD12; JET-X CCD) fabricated on a high-resistivity $(1.5k\Omega-cm)\;65{\mu}m$ thick epi-layer, on a $550{\mu}m$ thick p+ substrate, which is optimized for X-ray detection. Accurate predictions of the Potential minimum and barrier height of a CCD Pixel as a function of mobile electrons are found to give good charge transfer. The depletion depth approximation as a function of gate and substrate bias voltage provided average errors of less than 6%, compared with the results estimated from X-ray detection efficiency measurements. The result obtained from the transient simulation of signal charge movement is also presented based on 3-Dimensional analysis.

Analysis of the Critical Characteristics in the Superconducting Strip Lines by ICP Etching System (ICP 식각 시스템에 의한 초전도 스트립 라인의 임계 특성 분석)

  • 고석철;강형곤;최효상;양성채;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.7
    • /
    • pp.782-787
    • /
    • 2004
  • Superconducting flux flow transistor (SFFT) is based on a control of the Abrikosov vortex flowing along a channel. The induced voltage by moving of the Abrikosov vortex in an SFFT is greatly affected by the thickness, the width, and the length of channel. In order to fabricate a reproducible channel in the SFFT, we studied the variation of the critical characteristics of ${YBa}_2{Cu}_3{O}_7-\delta(YBCO)$ thin films with the etching time using ICP (Inductively coupled plasma) system. From the simulation, it was certified that the vortex velocity was increased in a low pinning energy at channel width 0,5 mm. The surfaces of YBCO thin film were etched by ICP etching system. We observed the etched channel surfaces by AFM (Atomic Force Microscope) and measured the critical current density with etching time. As a measured results, the etching thickness of channel should be optimized to fabricated a flux flow transistor with specified characteristics.

A Study of Transonic Premixed Combustion in a Diverging Channel Using Asymptotic Analysis (점근해석을 이용한 확대형 채널 내의 천음속 예혼합 연소에 관한 연구)

  • Lee, Jang-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.75-83
    • /
    • 2005
  • A steady transonic dilute premixed combustion in a diverging channel is investigated by using asymptotic analysis. This model explores the nonlinear interactions between the near-sonic speed of the flow, the small changes in geometry from a straight channel, and the small heat release due to the one-step first-order Arrhenius chemical reaction. The reactive flow is described by a nonhomogeneous transonic small-disturbance (TSD) equation coupled with an ordinary differential equation for the calculation of the reactant mass fraction in the combustible gas. Also the asymptotic analysis reveals the similarity parameters that govern the reacting flow problem. The results show the complicated nonlinear interaction between the convection, reaction, and geometry effects and its effect on the flow behavior.

Application of a new neutronics/thermal-hydraulics coupled code for steady state analysis of light water reactors

  • Safavi, Amir;Esteki, Mohammad Hossein;Mirvakili, Seyed Mohammad;Arani, Mehdi Khaki
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1603-1610
    • /
    • 2020
  • Due to ever-growing advancements in computers and relatively easy access to them, many efforts have been made to develop high-fidelity, high-performance, multi-physics tools, which play a crucial role in the design and operation of nuclear reactors. For this purpose in this study, the neutronic Monte Carlo and thermal-hydraulic sub-channel codes entitled MCNP and COBRA-EN, respectively, were applied for external coupling with each other. The coupled code was validated by code-to-code comparison with the internal couplings between MCNP5 and SUBCHANFLOW as well as MCNP6 and CTF. The simulation results of all code systems were in good agreement with each other. Then, as the second problem, the core of the VVER-1000 v446 reactor was simulated by the MCNP4C/COBRA-EN coupled code to measure the capability of the developed code to calculate the neutronic and thermohydraulic parameters of real and industrial cases. The simulation results of VVER-1000 core were compared with FSAR and another numerical solution of this benchmark. The obtained results showed that the ability of the MCNP4C/COBRA-EN code for estimating the neutronic and thermohydraulic parameters was very satisfactory.

Transient full core analysis of PWR with multi-scale and multi-physics approach

  • Jae Ryong Lee;Han Young Yoon;Ju Yeop Park
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.980-992
    • /
    • 2024
  • Steam line break accident (SLB) in the nuclear reactor is one of the representative Non-LOCA accidents in which thermal-hydraulics and neutron kinetics are strongly coupled each other. Thus, the multi-scale and multi-physics approach is applied in this study in order to examine a realistic safety margin. An entire reactor coolant system is modelled by system scale node, whereas sub-channel scale resolution is applied for the region of interest such as the reactor core. Fuel performance code is extended to consider full core pin-wise fuel behaviour. The MARU platform is developed for easy integration of the codes to be coupled. An initial stage of the steam line break accident is simulated on the MARU platform. As cold coolant is injected from the cold leg into the reactor pressure vessel, the power increases due to the moderator feedback. Three-dimensional coolant and fuel behaviour are qualitatively visualized for easy comprehension. Moreover, quantitative investigation is added by focusing on the enhancement of safety margin by means of comparing the minimum departure from nucleate boiling ratio (MDNBR). Three factors contributing to the increase of the MDNBR are proposed: Various geometric parameters, realistic power distribution by neutron kinetics code, Radial coolant mixing including sub-channel physics model.

Analysis of Performance Characteristics by Inner Flow Path of Side Channel Type Ring Blower (사이드 채널형 링블로워의 임펠러 내부 유로에 따른 성능변화 분석)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeong, Kyung-Ho;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.67-71
    • /
    • 2012
  • This study analyzed performance changes by an inner flow path of impeller groove for side channel type ring blower using CFD. Two models have the same side channel and clearance while one has an inner flow path and the other doesn't. To analyze the performance change of a ring blower, overall performance and local flow field were analyzed. For the overall performance, pressure increase and impeller torque were checked under the design flow condition. Under the design flow condition, pressure increase was greater for the model with the inner flow path. The model with the inner flow path showed improved efficiency because the area subject to torque decreased due to the creation of inner flow path. To analyze local flow field, a section was created from the representative location of each impeller groove toward the direction of radius. Inner channel pressure distribution depending on the rotation direction shows that the model with the inner flow path has pressure equilibrium of working fluid through the inner flow path. Velocity distribution of inside impeller groove shows that flow field was coupled and appeared to form an inner wall where the flow field was stabilized.

Numerical Simulation of the Oscillating Flow Effect in the Channel of Polymer Electrolyte Membrane Fuel Cell (왕복 유동을 통한 확산증대 효과가 연료전지 성능에 미치는 영향에 대한 수치해석)

  • Kim, Jongmin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.4
    • /
    • pp.7-13
    • /
    • 2018
  • This study investigates the enhancement of the oxygen diffusion rate in the cathode channel of a proton exchange membrane fuel cell (PEMFC) by pure oscillating flow, which is the same as the mechanism of human breathe. Three-dimensional numerical simulation, which has the full model of the fuel cell including electrochemical reaction, ion and electronic conduction, mass transfer and thermal variation and so on, is performed to show the phenomena in the channel at the case of a steady state. This model could analysis the oscillating flow as a moving mesh calculation coupled with electrochemical reaction on the catalyst layer, however, it needs a lot of calculation time for each case. The two dimensional numerical simulation has carried on for the study of oscillating flow effect in the cathode channel of PEMFC in order to reduce the calculation time. This study shows the diffusion rate of the oxygen increased and the emission rate of the water vapor increased in the channel by oscillating flow without any forced flow.