• Title/Summary/Keyword: Coupled Charge Device

Search Result 237, Processing Time 0.022 seconds

Error-Correcting 7/9 Modulation Codes For Holographic Data Storage

  • Lee, Kyoungoh;Kim, Byungsun;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.2
    • /
    • pp.86-91
    • /
    • 2014
  • Holographic data storage (HDS) has a number of advantages, including a high transmission rate through the use of a charge coupled device array for reading two-dimensional (2D) pixel image data, and a high density capacity. HDS also has disadvantages, including 2d intersymbol interference by neighboring pixels and interpage interference by multiple pages stored in the same holographic volume. These problems can be eliminated by modulation codes. We propose a 7/9 error-correcting modulation code that exploits a Viterbi-trellis algorithm and has a code rate larger (about 0.778) than that of the conventional 6/8 balanced modulation code. We show improved performance of the bit error rate with the proposed scheme compared to that of the simple 7/9 code without the trellis scheme and the 6/8 balanced modulation code.

Grinding disk detection with image processing and application to face recognition (화상처리를 이용한 연삭공구 인식 및 안면인식 응용)

  • 백재용;송무건;유송민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.115-118
    • /
    • 2001
  • An image processing method was applied to characterize a shape of the flexible grinding disk. A disk surface image was taken by CCD camera. Depth of cut was changed to be 2 and 4mm. Circles marked on the disk were captured to extract the key features of the deflection. Notable correlation has been observed between the intervals and the process conditions. Same methodology has been applied to check the symmetry of the human face. Tentative results revealed that symmetry could be checked using the filtered face image.

  • PDF

Evaluation for 3-D Reconstruction Accuracy Using Zoom-lens CCD Camera (줌 렌즈 CCD 카메라를 이용한 3차원 복원 정확도 평가)

  • 김성삼;정상용;박홍기;유환희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.369-376
    • /
    • 2003
  • 최근 고해상력을 가진 줌 렌즈 CCD(Charge Coupled Device) 카메라가 출시되면서 디지털 영상을 쉽게 취득할 수 있게 되어 일상적인 활용에서부터 컴퓨터 시각(computer vision)이나 사진측량과 같은 전문적인 분야에 이르기까지 다양하게 응용할 수 있는 계기가 마련되고 있다. 현재 상용되고 있는 일반 줌 렌즈 CCD 카메라는 영상을 취득하는 데 많은 장점을 갖고 있으나 실제 영상 취득과정에서 다양한 줌의 이동으로 인하여 표정요소계산 및 카메라 렌즈 오차검정에 상당한 어려움이 발생하여 이에 대한 연구가 진행되어오고 있다. 본 연구에서는 기존에 비측량용 카메라에서 취득된 영상을 해석하는 기법으로 사진측량 분야에서 사용되어온 DLT(Direct Linear Transformation) 모델식과 컴퓨터 시각(computer vision)분야에서 카메라 검정 및 3차원 복원에 사용되고 있는 Tsai 모델식을 도입ㆍ적용하여 표정요소계산 및 3차원 복원정확도를 비교 분석하였다. 그 결과 Tsai 모델식에 의한 결과가 DLT 모델식에 의한 결과보다 정확도 및 안정성면에서 향상된 결과를 보여주고 있어서 Tsai 모델식에 대한 사용이 기대된다.

  • PDF

The Merging Method of Point Data with Point Pattern Matching in 3D Measurement (3차원 형상측정에서 점 패턴매칭을 이용한 점 데이터의 결합방법)

  • 조택동;이호영;양상민
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.714-719
    • /
    • 2003
  • We propose a measuring method of large object using the pattern matching. It is hard and expensive to get the complete 3D data when the object is large and exceeds the limit of measuring devices. The large object is divided into several smaller areas and is scanned several times to get the data of all the pieces. These data are aligned to get the complete 3D data using the pattern matching method such as point pattern matching method and transform matrix algorithm. The laser slit beam and CCD camera are applied for the experimental measurement. Visual C++ on Windows 98 is implemented in processing the algorithm.

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

Two Step on-axis Digital Holography Using Dual-channel Mach-Zehnder Interferometer and Matched Filter Algorithm

  • Lee, Hyung-Chul;Kim, Soo-Hyun;Kim, Dae-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.363-367
    • /
    • 2010
  • A new two step on-axis digital holography (DH) is proposed without any assumptions, phase shifting, or complicated optical components. A dual-channel Mach-Zehnder interferometer was employed. Using that setup, the object field can be reconstructed requiring only two step measurements. To eliminate position difference between two charge-coupled device (CCD) cameras, a matched filter algorithm was used. Experimental results are compared to those of the traditional phase shifting technique. The proposed approach can also be applied to single-exposure on-axis DH for real time measurement.

대장내시경검사의 최신지견

  • Jeong, In-Seop
    • Journal of radiological science and technology
    • /
    • v.27 no.1
    • /
    • pp.13-16
    • /
    • 2004
  • 대장내시경검사는 역사적으로 돌아보면 원래 히포크라테스의 치루치료과정에서 직장경 사용으로부터 유래되며 그 후 Kelly의 25 cm 표준 S상 결장경의 발견으로 진전되었고 조명 및 각종 부속기구들이 많이 개선되면서 직장암의 발견에 기여해 왔다. 1911년에 독일 뮌헨의 Michael Hoffman이라는 광학 기술자가 프리즘을 여러 개를 연결하면 직선이 아닌 곡선에서도 빛을 그대로 전달할 수 있다는 사실을 발견하였고 이를 기초로 하여 1958년에 미국에서 Hirschowitz가 처음으로 섬유경(fiberscope)을 선보였고 그 이후 이용한 상부소화관에 대한 내시경 기술이 급속히 발전하기 시작하였고, 이를 기초로 1969년부터 ACMI, Olympus, Fujinon, Pentax 등 세계 유수의 내시경 회사들이 대장내시경을 제작하기 시작하였다. 1983년에 미국의 Welch-Allyn사가 CCD(Charge Coupled Device)라는 집광 장치를 만들어서 마치 내시경의 눈과 같은 작용을 해서 이것을 내시경 선단에 장치하고 전파를 이용하여 영상을 전달하여 이 상이 TV 모니터에 비치는 것을 보게 되는 전자내시경을 개발하여 현재는 상부내시경 뿐 아니라 대장내시경도 대부분이 전자 내시경으로 대체되어서 오늘에 이르고 있다.

  • PDF

Discharge Dynamics of AC Plasma Display Panel

  • Whang, Ki-Woong;Seo, Jeong-Hyun;Yoon, Cha-Keun;Chung, Woo-Joon;Kim, Joong-Kyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.53-57
    • /
    • 1999
  • To investigate the discharge dynamics of alternating current plasma display panel (ACPDP), we measured the spatio-temporally resolved VUV and IR emission by an intensified charge coupled device (CCD). The breakdown beings around the anode inner edge and moves towards the cathode surface. As the ionization intensifies in front of the cathode surface, another emission region appears on the anode surface. While the anode side emission does not move but grows, the cathode side emission moves out and spreads over the entire cathode surface. The discharge dynamics emission by a 2 dimensional numerical simulation suggests that a cathode-directed streamer formation play an important role.

  • PDF

A Study on CAD/CAM Pocket Processing using the High Speed Machine (고속가공기를 이용한 CAD/CAM 포켓가공에 관한 연구)

  • Yoo, Chun-Hea;Lee, Yuk-Hyung;Song, Joon-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.3
    • /
    • pp.32-38
    • /
    • 2004
  • Recently, the system of high speed milling(HSM) is widely used for reducing the operation time and maximizing efficiency of work. The most research of high speed milling system is still leaves much to be desired. Specially the research of mass pocket high speed processing with high precision is the first and probably the last. So this paper showed mass pocket processing of high precision with a duralumin and then confirmed a cause of inferior goods through the CAD/CAM pattern simulation and experimentation. And this paper showed high speed processing system reduce the rate of inferior from this optimal pattern.

  • PDF

Tabular Methods for the Design of Multivalued Logic Circuits Using CCD (CCD를 이용한 다치논린회로의 설계에 관한 Tabular법)

  • 송홍복;정만영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.5
    • /
    • pp.411-421
    • /
    • 1988
  • This paper offers a method to design CCD four-valued circuits using the tabular method. First, the four-valued logic function is decomposed by hand-calculation or computer program. Nest, the algorithm is derived form the tabular method based on the decomposition process to realize the DDC four-valued circuit. According to this algorithm, the two-variable four valued logic function is decomposed and realized by CCD network with four basic gates. The synthesis method in this paper proves that the number of devices and cost is considerably reduces as compared with the existing methods to realize the same logic functions.

  • PDF