• Title/Summary/Keyword: Coupled Charge Device

Search Result 237, Processing Time 0.028 seconds

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Imaging Performance Analysis of an EO/IR Dual Band Airborne Camera

  • Lee, Jun-Ho;Jung, Yong-Suk;Ryoo, Seung-Yeol;Kim, Young-Ju;Park, Byong-Ug;Kim, Hyun-Jung;Youn, Sung-Kie;Park, Kwang-Woo;Lee, Haeng-Bok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.174-181
    • /
    • 2011
  • An airborne sensor is developed for remote sensing on an aerial vehicle (UV). The sensor is an optical payload for an eletro-optical/infrared (EO/IR) dual band camera that combines visible and IR imaging capabilities in a compact and lightweight package. It adopts a Ritchey-Chr$\'{e}$tien telescope for the common front end optics with several relay optics that divide and deliver EO and IR bands to a charge-coupled-device (CCD) and an IR detector, respectively. The EO/IR camera for dual bands is mounted on a two-axis gimbal that provides stabilized imaging and precision pointing in both the along and cross-track directions. We first investigate the mechanical deformations, displacements and stress of the EO/IR camera through finite element analysis (FEA) for five cases: three gravitational effects and two thermal conditions. For investigating gravitational effects, one gravitational acceleration (1 g) is given along each of the +x, +y and +z directions. The two thermal conditions are the overall temperature change to $30^{\circ}C$ from $20^{\circ}C$ and the temperature gradient across the primary mirror pupil from $-5^{\circ}C$ to $+5^{\circ}C$. Optical performance, represented by the modulation transfer function (MTF), is then predicted by integrating the FEA results into optics design/analysis software. This analysis shows the IR channel can sustain imaging performance as good as designed, i.e., MTF 38% at 13 line-pairs-per-mm (lpm), with refocus capability. Similarly, the EO channel can keep the designed performance (MTF 73% at 27.3 lpm) except in the case of the overall temperature change, in which the EO channel experiences slight performance degradation (MTF 16% drop) for $20^{\circ}C$ overall temperate change.

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

A Study on the Method of High-Speed Reading of Postal 4-state Bar Code for Supporting Automatic Processing (우편용 4-state 바코드 고속판독 방법에 관한 연구)

  • Park, Moon-Sung;Kim, Hye-Kyu;Jung, Hoe-Kyung
    • The KIPS Transactions:PartD
    • /
    • v.8D no.3
    • /
    • pp.285-294
    • /
    • 2001
  • Recently many efforts on the development of automatic processing system for delivery sequency sorting have been performed in ETRI, which requires the use of postal 4-state bar code system to encode delivery points. This paper addresses the issue on the extension of read range and the improvement of image processing method. For the improvement of image processing procedure, applied information acquisition method through basic two thresholds onto the horizontal axial line of gray image based on reference information of 4-state bar code symbology. Symbol values are computed after creating two threshold values based on the obtained information through search of horizontal axial values. The implementation result of 4-state bar code reader are obtained the symbol values within 30~60 msec (58,000~116,000 mail item/hour)without noise removal or image rotation in spite of the incline $\pm 45^{\circ}$.

  • PDF

Effect of alternative farrowing pens with temporary crating on the performance of lactating sows and their litters

  • Si Nae, Cheon;So Hee, Jeong;Guem Zoo, Yoo;Se Jin, Lim;Chan Ho, Kim;Gul Won, Jang;Jung Hwan, Jeon
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.574-587
    • /
    • 2022
  • This study was performed to development the alternative farrowing pen (AFP) and to investigate performance and behavior of lactating sows and their litter. A total of 64 multiparous sows were randomly divided into two groups and were allocated to farrowing crates (FCs) and AFPs. The AFPs contained a crate and support bars that could be folded to provide the sows with extra space on day 5 postpartum. Behavior was recorded by charge-coupled device cameras and digital video recorders, and the data were scanned every 2 min to obtain an instantaneous behavioral sample. Farrowing systems did not affect feed intake, back-fat thickness, litter size and piglet weight at birth and weaning (p > 0.05). In addition, there were no differences in the number of crushed piglets between the two farrowing systems (p > 0.05). However, the weaning-to-estrus interval was shorter in the sows of the AFPs than in thous of the FCs (p < 0.05). The sows spent most of their time lying down during the lactating period, at about 80% lateral recumbency and 10%-15% ventral recumbency. The only significant differences were in the feeding and drinking behavior between sows in the two farrowing systems (p < 0.05). The FC sows displayed more feeding and drinking behavior than the AFP sows, especially in the late lactating period (p < 0.05). Piglets in the FCs tended to spend more time walking than piglets in the AFPs (p < 0.05), whereas there were no differences in suckling and lying behavior between piglets in the two farrowing systems (p > 0.05). It is concluded that the AFPs with temporary crating until day 4 postpartum did not negatively affect performance and crushed piglet compared with the FCs. It also may improve animal welfare by allowing sows to move and turn around during the lactating period. Further research is needed to find suitable housing designs to enhance productivity and animal welfare.

Effect of the Flavonoid Luteolin for Dextran Sodium Sulfate-induced Colitis in NF-${\kappa}B^{EGFP}$ Transgenic Mice (Dextran Sodium Sulfate 유발 장염 모델에서 루테올린의 치료효과)

  • Jang, Byung-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.26-35
    • /
    • 2006
  • Background: Luteolin, a flavone found in various Chinese herbal medicines is known to possess anti-inflammatory properties through its ability to inhibit various proinflammatory signaling pathways including NF-${\kappa}B$ and p38 MAPK. In this study, we investigated the potential therapeutic effect of luteolin on dextran sodium sulfate (DSS)-induced colitis. Materials and Methods: We used a transgenic mouse model expressing the enhanced green fluorescent protein (EGFP) under the transcriptional control of NF-${\kappa}B$ $cis$-elements. C57BL/6 NF-${\kappa}B^{EGFP}$ mice received 2.5% DSS in their drinking water for six days in combination with daily luteolin administration (1mg/kg body weight, 0.1ml vol, intragastric) or vehicle. NF-${\kappa}B$ activity was assessed macroscopically with a Charge-Coupled Device (CCD) camera and microscopically by confocal analysis. Results: A significant increase in the Disease Activity Index (DAI), histological score (p<0.05), IL-12 p40 secretion in colonic stripe culture (p<0.05) and EGFP expression was observed in luteolin and/or DSS-treated mice compared to water-treated mice. Interestingly, a trend toward a worse colitis (DAI, IL-12p40) was observed in luteolin-treated mice compared to non-treated DSS-exposed mice. In addition, EGFP expression (NF-${\kappa}B$ activity) strongly increased in the luteolin-treated mice compared to control mice. Confocal microscopy showed that EGFP positive cells were primarily lamina propria immune cells. Conclusions: These results suggest that luteolin is not a therapeutic alternative for intestinal inflammatory disorders derived for primary defects in barrier function. Thus, therapeutic intervention targeting these signaling pathways should be viewed with caution.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.