• Title/Summary/Keyword: Counting efficiency

Search Result 153, Processing Time 0.028 seconds

A study on prediction of whipping effect of very large container ship considering multiple sea states

  • Kim, Beomil;Choung, Joonmo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.387-398
    • /
    • 2020
  • In the design stage of the very large container ships, some methodologies for the whipping effects have been developed, but most of them are based on single sea state. We developed a methodology that considers multiple sea states. Fluid-structure Interaction (FSI) analyses with one dimensional structural model were carried out to capture slamming-induced transient whipping behaviors. Because of the nature of random phases of the applied wave spectra, the required period for entire FSI analyses was determined from the convergence study where the whipping effect became stable. Low pass filtering was applied to the transient whipping responses to obtain the hull girder bending moment processes. Peak counting method for the filtered whipping responses was used to obtain collection of the vertical bending moment peaks. The whipping effect from this new method is compared with that from based on single sea state approach. The efficiency and advantage of the new methodology are presented.

The Analysis of Financial of Condition: the Features of the Application of Concentric Matric Modeless

  • Nikolaevna, Vyborova Elena
    • The Journal of Economics, Marketing and Management
    • /
    • v.7 no.1
    • /
    • pp.39-50
    • /
    • 2019
  • Purpose - The article views the theoretical basis of adaptation concentric matrix models in the analysis of the financial condition of the organization. Presented the elements counting procedures in the assessment of economic stability. Research design, data, and Methodology - Used the economic indicates in the concentric matrix models. The article views the specific using the concentric matrix models in the analysis of the financial condition of the organization. Results - The concentric matrix models can be adaptation to the analysis of financial conditions of organizations and to the comparative analysis. In the process of analysis of economic stability can be used "a field of efficiency". The classical variant of methods is transformed. The detailed assessment of influence of individual factors defined the additional methods. Conclusions - In the article the methods are demonstrated on the material of organization (Hyundai Elevator Co, China Communications Construction Company).

A TabNet - Based System for Water Quality Prediction in Aquaculture

  • Nguyen, Trong–Nghia;Kim, Soo Hyung;Do, Nhu-Tai;Hong, Thai-Thi Ngoc;Yang, Hyung Jeong;Lee, Guee Sang
    • Smart Media Journal
    • /
    • v.11 no.2
    • /
    • pp.39-52
    • /
    • 2022
  • In the context of the evolution of automation and intelligence, deep learning and machine learning algorithms have been widely applied in aquaculture in recent years, providing new opportunities for the digital realization of aquaculture. Especially, water quality management deserves attention thanks to its importance to food organisms. In this study, we proposed an end-to-end deep learning-based TabNet model for water quality prediction. From major indexes of water quality assessment, we applied novel deep learning techniques and machine learning algorithms in innovative fish aquaculture to predict the number of water cells counting. Furthermore, the application of deep learning in aquaculture is outlined, and the obtained results are analyzed. The experiment on in-house data showed an optimistic impact on the application of artificial intelligence in aquaculture, helping to reduce costs and time and increase efficiency in the farming process.

On Implementing the Digital DTMF Receiver Using PARCOR Analysis Method (PARCOR 분석 방법에 의한 디지털 DTMF 수신기 구현에 관한 연구)

  • Ha, Pan Bong;ANN, Souguil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.196-200
    • /
    • 1987
  • The following methods are proposed for implementing digital dual tone multi-frequency (DTMF) receiver: using infinite impulse response(IIR) digital filters, period-counting algorithm, discrete Fourier transform(DFT), and fast Fourier transform(FFT)[2]. The PARCOR(Partical Correlation) analysis method which has been widly used in the speech signal processing area is applied to the dual tone multi-frequency(DTMF) signal detection. This method is easy to implement digitally and stronger to digit simulation of speech than any other methods proposed up to date. Since sampling rate of 4KHz is used in the DTMF receiver for the detection of input DTMF signal originally sampled at 8KHz, it effects two times higher multiplexing efficiency.

  • PDF

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

3D Fusion Imaging based on Spectral Computed Tomography Using K-edge Images (K-각 영상을 이용한 스펙트럼 전산화단층촬영 기반 3차원 융합진단영상화에 관한 연구)

  • Kim, Burnyoung;Lee, Seungwan;Yim, Dobin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.523-530
    • /
    • 2019
  • The purpose of this study was to obtain the K-edge images using a spectral CT system based on a photon-counting detector and implement the 3D fusion imaging using the conventional and spectral CT images. Also, we evaluated the clinical feasibility of the 3D fusion images though the quantitative analysis of image quality. A spectral CT system based on a CdTe photon-counting detector was used to obtain K-edge images. A pork phantom was manufactured with the six tubes including diluted iodine and gadolinium solutions. The K-edge images were obtained by the low-energy thresholds of 35 and 52 keV for iodine and gadolinium imaging with the X-ray spectrum, which was generated at a tube voltage of 100 kVp with a tube current of $500{\mu}A$. We implemented 3D fusion imaging by combining the iodine and gadolinium K-edge images with the conventional CT images. The results showed that the CNRs of the 3D fusion images were 6.76-14.9 times higher than those of the conventional CT images. Also, the 3D fusion images was able to provide the maps of target materials. Therefore, the technique proposed in this study can improve the quality of CT images and the diagnostic efficiency through the additional information of target materials.

Signal Level Analysis of a Camera System for Satellite Application

  • Kong, Jong-Pil;Kim, Bo-Gwan
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.220-223
    • /
    • 2008
  • A camera system for the satellite application performs the mission of observation by measuring radiated light energy from the target on the earth. As a development stage of the system, the signal level analysis by estimating the number of electron collected in a pixel of an applied CCD is a basic tool for the performance analysis like SNR as well as the data path design of focal plane electronic. In this paper, two methods are presented for the calculation of the number of electrons for signal level analysis. One method is a quantitative assessment based on the CCD characteristics and design parameters of optical module of the system itself in which optical module works for concentrating the light energy onto the focal plane where CCD is located to convert light energy into electrical signal. The other method compares the design\ parameters of the system such as quantum efficiency, focal length and the aperture size of the optics in comparison with existing camera system in orbit. By this way, relative count of electrons to the existing camera system is estimated. The number of electrons, as signal level of the camera system, calculated by described methods is used to design input circuits of AD converter for interfacing the image signal coming from the CCD module in the focal plane electronics. This number is also used for the analysis of the signal level of the CCD output which is critical parameter to design data path between CCD and A/D converter. The FPE(Focal Plane Electronics) designer should decide whether the dividing-circuit is necessary or not between them from the analysis. If it is necessary, the optimized dividing factor of the level should be implemented. This paper describes the analysis of the electron count of a camera system for a satellite application and then of the signal level for the interface design between CCD and A/D converter using two methods. One is a quantitative assessment based on the design parameters of the camera system, the other method compares the design parameters in comparison with those of the existing camera system in orbit for relative counting of the electrons and the signal level estimation. Chapter 2 describes the radiometry of the camera system of a satellite application to show equations for electron counting, Chapter 3 describes a camera system briefly to explain the data flow of imagery information from CCD and Chapter 4 explains the two methods for the analysis of the number of electrons and the signal level. Then conclusion is made in chapter 5.

  • PDF

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Study on Gross-alpha Characteristics of Groundwater for Drinking in Korea (국내 음용지하수중 전알파 특성 연구)

  • Jeong, Do-Hwan;Lee, Young-Joon;Ju, Byoung-Kyu;Noh, Hoe-Jung;Yu, Soon-Ju;Kim, Moon-Su
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.5
    • /
    • pp.67-73
    • /
    • 2011
  • Groundwaters were sampled from 730 wells being used for drinking purposes during 2007-2009. These samples were analysed using a gas-flow type GPC (Gas Proportional Counter) according to the USEPA method (900.0). We obtained a gross-alpha counting TDS (total dissolved solid) efficiency curve (Y = 0.0017X2 - 0.3122X + 19.165, X = TDS, Y = efficiency, $R^2$ = 0.9734) using natural uranium standard to get gross ${\alpha}$ value of the samples. The gross alpha values ranged from MDA (minimum detectable activity) to 14.88 pCi/L and 429 samples showed values higher than MDA (< 0.9 pCi/L). Correlations of the uranium values with the total alpha values and the gross-alpha values indicate that uranium values have high impacts on gross-alpha values. Groundwater samples of study areas were classified into four regions according to the rock types; plutonic (granite) rock region (427 areas), metamorphic rock region (181 aeras), sedimentary rock region (70 areas), volcanic rock region (52 areas). Groundwater of Cretaceous granite presented the highest gross-alpha value. Gross alpha in groundwaters showed no relationship with uranium in terms of the geological ages, rocks and minerals.

In-Situ Gamma Spectrometry Research Analysis and Radiation Efficiency Sensitivity Evaluation (감마핵종 In-Situ 측정 연구 동향 분석 및 방사능 측정 효율 민감도 평가)

  • Hyun Jun Na;Hyeok Jae Kim;Seong Yeon Lee;Min Woo Kwak;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Since a large amount of radioactive waste is expected to be generated due to permanent shutdown of many nuclear power plants, it is necessary to prepare efficient management methods for radioactive waste. Therefore, there is a need for a based study to apply the In-Situ gamma spectrometry, which can simplify the measurement procedure. The purpose of this study is to analyze research cases of In-Situ gamma spectrometry and to analyze the sensitivity of measurement according to influencing factors on In-Situ gamma spectrometry. Research cases of five institutions, including the CERN and the Imperial College Reactor Centre (ICRC), were selected as the institutions to be investigated. Research on the In-Situ gamma spectrometry was conducted on the satisfaction of the acceptance criteria for radioactive waste and the analysis of residual radioactivity in the site. In-Situ Objective Counting System (ISOCS) was used as a major measuring device. Sampling and computer code were used to verify the analysis results. For evaluation of measuring sensitivity according to influencing factors on In-Situ gamma spectrometry, the thickness of the measurement target, the distance between the detector and the target, the angle of the collimator, and the contamination location were performed using ISOCS's Geometry Composer. In every case, based on 122 keV, the efficiency decreased as the energy increased in the high energy region, and the efficiency decreased as the energy decreased in the low energy region. As the target thickness increased, the efficiency decreased, and as the distance between target and detector increased, the efficiency decreased. As the distance between contamination and detector increased, the efficiency decreased, and as the angle of the collimator increased, the measurement efficiency increased. However, when simulating the measurement situation using Geometry Composer, the background is not considered, and the probability of incident in the background increases as the angle increases, so further research needs to be conducted in consideration of these. This study can be utilized when applying the In-Situ gamma spectrometry of radioactive waste clearance in the future.