• 제목/요약/키워드: Counting efficiency

검색결과 151건 처리시간 0.028초

고효율 사이클론의 집진효율에 관한 연구 (A Study of High Particle Collection Efficiency of Cyclone)

  • 정진도;이상권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2227-2232
    • /
    • 2003
  • For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

  • PDF

광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구 (A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application)

  • 박지군;노시철;최일홍;정봉재;강상식
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.423-428
    • /
    • 2014
  • 현재까지 TFT 기반의 평판형 어레이를 이용한 디지털 X선 영상장치가 이용되어 왔다. 그러나, 최근 광계수형 센서 기술에 대한 많은 연구가 수행되고 있다. 본 연구에서는 광계수형 X선 영상 센서의 정량적 성능 평가를 위한 기시법 제시를 통해 광도전체 물질의 물성을 평가하였다. 먼저 광계수형 X선 영상 센서의 검출물질인 광도전체의 누설전류 및 X선 민감도 측정을 수행하였으며, 신호 정형 시간 결정을 위한 상승시간 특성을 평가하였다. 또한 광도전체에 입사하는 단위면적당 포톤수를 정의하기 위해 IEC 62220-1-2 권고안을 바탕으로 셋업 연구를 수행하였으며, 이를 바탕으로 전하수집효율를 평가하였다. 그 결과 광도전체 층의 누설전류는 $200pA/mm^2$, X선 민감도는 $7{\mu}C/cm^2R$이며, 상승 시간은 $0.765{\mu}s$으로 평가되었다.

CHEST WALL THICKNESS MEASUREMENTS AND THE DOSIMETRIC IMPLICATIONS FOR MALE RADIATION WORKERS AT THE KAERI

  • Lee, Tae-Young;Lee, Jong-Il;Chang, Si-Young;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.299-303
    • /
    • 2001
  • Using ultrasound techniques, the Korea Atomic Energy Research Institute has measured chest wall thicknesses of a group of male workers at the Korea Atomic Energy Research Institute. A site-specific biometric equation has been developed for these workers. Chest wall thickness is an important modifier on lung counting efficiency. These data have been put into the perspective of the ICRP recommended dose limits for occupationally exposed workers: 100 mSv in a 5-year period with a maximum of 50 mSv in anyone year. For measured chest wall thicknesses of 1.9 cm to 4.1 cm and a 30 min counting time, the achievable MDAs for natural uranium in the KAERI lung counter vary from 5.75 mg to 11.28 mg. These values are close to, or even exceed, the predicted amounts of natural uranium that will remain in the lung (absorption type M and S) after an intake equal to the Annual Limit on Intake corresponding to a committed dose of 20 mSv. This paper shows that the KAERI lung counter probably cannot detect an intake of Type S natural uranium in a worker with a chest wall thickness equal to the average value (2.7 cm) under routine counting conditions.

  • PDF

$^14C$년대측정을 위한 벤젠 합성 및 액체섬광계측의 최적 조건 (Optimum conditions of benzene synthesis and liquid scintillation counting fir radiocarbon dating)

  • 강형태;나경임
    • 보존과학연구
    • /
    • 통권15호
    • /
    • pp.21-32
    • /
    • 1994
  • Optimum conditions for benzene synthesis and liquid scintillation counting have been studied for the determination of radiocarbon age. In benzene synthesis the carbon dioxide converted to benzene with high efficiency of 91%. Yields of each step with 10L of carbon dioxide were $CO_2$ $\rightarrow$$C_2H_2$(94%), $C_2H_2$$\rightarrow$$C_6H_6$(96%) and$CO_2$$\rightarrow$$C_6H_6$(91%), respectively. Benzene synthesized from oxalate was measured with purity of 95% by GC /MS. $\delta^13$(C$^13$C/$^12$C) of oxalate was measured to $-24.7\{textperthousand}$ by massspectrometer. For liquid scintillation counting of benzene sample low background and highest FOM were measured in 0.5 ml cocktail and 3 ml standard solution with the range of 15.4∼74.9 KeV window setting. Oxalate and background samples weremeasured to $28.7\pm0.12$cpm and $3.92\pm0.04$ cpm in 15.4∼74.9 KeV

  • PDF

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • 제18권2호
    • /
    • pp.56-60
    • /
    • 1975
  • 완두유묘의 자엽 및 뿌리조직중 탄소-14 방사능을 Liquid scintillation counter로 신속히 측정하는 새로운 방법에 관하여 실험하였다. 식물조직을 액체공기에 처리하여 분쇄한 다음 Gel phosphor에 헌탁시켜, Liquid scintillation counter로 측정하였다. 이시료에 다시 내부표준물질을 가한 다음 계측효율을 구하여 Apparent absolute activity를 얻었다. 이렇게 얻은 헌탁시료의 절대방사능은 자기 흡수현상 때문에, 따로 Flask combustion 방법으로 구한 절대방사능 보다는 낮았으나, 항상 비례하였다. 따라서 동일한 실험조건하에서 상술한 비율을 얻으면, 완두조직중 탄소-14의 점대방사능은, 비교적 간편한 헌탁측정(suspension counting) 만으로 가능하였다. 본방법은 완두 외에 다른 식물조직중 탄소-14 분석에도 쓰일 수 있다.

  • PDF

Multi-Frame Face Classification with Decision-Level Fusion based on Photon-Counting Linear Discriminant Analysis

  • Yeom, Seokwon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제14권4호
    • /
    • pp.332-339
    • /
    • 2014
  • Face classification has wide applications in security and surveillance. However, this technique presents various challenges caused by pose, illumination, and expression changes. Face recognition with long-distance images involves additional challenges, owing to focusing problems and motion blurring. Multiple frames under varying spatial or temporal settings can acquire additional information, which can be used to achieve improved classification performance. This study investigates the effectiveness of multi-frame decision-level fusion with photon-counting linear discriminant analysis. Multiple frames generate multiple scores for each class. The fusion process comprises three stages: score normalization, score validation, and score combination. Candidate scores are selected during the score validation process, after the scores are normalized. The score validation process removes bad scores that can degrade the final output. The selected candidate scores are combined using one of the following fusion rules: maximum, averaging, and majority voting. Degraded facial images are employed to demonstrate the robustness of multi-frame decision-level fusion in harsh environments. Out-of-focus and motion blurring point-spread functions are applied to the test images, to simulate long-distance acquisition. Experimental results with three facial data sets indicate the efficiency of the proposed decision-level fusion scheme.

Development of a Real-Time Automatic Passenger Counting System using Head Detection Based on Deep Learning

  • Kim, Hyunduk;Sohn, Myoung-Kyu;Lee, Sang-Heon
    • Journal of Information Processing Systems
    • /
    • 제18권3호
    • /
    • pp.428-442
    • /
    • 2022
  • A reliable automatic passenger counting (APC) system is a key point in transportation related to the efficient scheduling and management of transport routes. In this study, we introduce a lightweight head detection network using deep learning applicable to an embedded system. Currently, object detection algorithms using deep learning have been found to be successful. However, these algorithms essentially need a graphics processing unit (GPU) to make them performable in real-time. So, we modify a Tiny-YOLOv3 network using certain techniques to speed up the proposed network and to make it more accurate in a non-GPU environment. Finally, we introduce an APC system, which is performable in real-time on embedded systems, using the proposed head detection algorithm. We implement and test the proposed APC system on a Samsung ARTIK 710 board. The experimental results on three public head datasets reflect the detection accuracy and efficiency of the proposed head detection network against Tiny-YOLOv3. Moreover, to test the proposed APC system, we measured the accuracy and recognition speed by repeating 50 instances of entering and 50 instances of exiting. These experimental results showed 99% accuracy and a 0.041-second recognition speed despite the fact that only the CPU was used.

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

활성탄 및 세라믹 재질에의 세균 부착성에 대한 연구 (An Experimental Study on Bacterial Adhesion onto Activated Carbon and Ceramic)

  • 권성현;조대철;이인형
    • 한국환경과학회지
    • /
    • 제14권12호
    • /
    • pp.1163-1170
    • /
    • 2005
  • The microbial adsorption characteristics of two different media for biological treatment were studied using attached diverse microbes onto activated carbon and ceramic. The results in the experiments of the characteristics of physical adhesion on two different media with addition of high and low concentrated substrate in the culture were observed that the efficient of adhesion onto F-400 activated carbon was higher over that of ceramic due to the surface area of media. The irradiation treatment by ultrasonication with 400 W power and 3 min retention time on the media without addition substrate conditions and subsequent mixing throughly the culture showed the highest efficiency of cell detachment on the media. Three different microbes, P. ovalis, A calcoaceticus, and B. subtillis were used for the study of the characteristics of microbial adhesion on the media. p ovalis showed the highest adhesion capability while B. subtillis showed the lowest capability adhesion onto media either addition of substrate in the culture. The mixed bacterial culture showed $10\%$ lower removal efficiency of DOC in the low concentrated substrate culture compared to the single pure culture. Whileas, it did not show significant difference between two cultures at high concentrated substrate. It was also observed same population density of microorganism by counting of microbes adhered to microbial media with an ultrasound treatment.