• Title/Summary/Keyword: Counting Device

Search Result 69, Processing Time 0.027 seconds

Development of a Contact-Type Counting Device Using a Piezoelectric Film as a Sensor (압전필름을 센서로 사용한 접촉식 계수장치 개발)

  • Yoo, Wan-Dong;Kim, Jin-Oh;Park, Kwang-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.239-247
    • /
    • 2005
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

Development of a Counting Device Using a Piezoelectric Sensor (압전 센서를 사용한 계수 장치 개발)

  • Yoo, Wan-Dong;Kim, Jin-Oh;Park, Kwang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1089-1092
    • /
    • 2004
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

  • PDF

Development of Automatic Seed Metering Device (자동제어식 파종조절장치 개발)

  • Lee, Y.K.;Lee, D.W.;Oh, Y.Z.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.91-98
    • /
    • 1994
  • Planting, transplanting, and harvesting are important processes for the successful production of farm products in Korea because those require the high labor intensity during limitted period. Recently, many researches of using automatic control with a microcomputer are carried in the agricultural field, but are not much spread to the seeder development. Automatic sowing technology would be much attractive if there was a way to assure that each seed was count accurately in the seed metering device. Thus, an automatic seed metering device was designed and constructed to be controlled by microcomputer. This device could be improved in not only counting the number of seeds in but also sowing seeds between row spacings. Automatic seed metering device consisted of conveyor belt and temporary storage device. Performance of seed metering device depends on the apparatus including sensor, stepping motor and DC-solenoid. Research contents and results are summarized as follows. 1. The seed metering device involving seed hopper, sorter and temporary storage device was designed and constructed. 2. A seed counting system with six photo electric sensors, designed and built for this project, was adequate for tranferring and counting seeds accurately. 3. Operating algorithm for stepping motor and photo electric DC-solenoid was developed. The Seed metering device proved to be a smooth and accurate operating device using the algorithm. 4. The performance of second prototype metering device was examined with five kinds of seeds ; mung beans, red beans, white beans, black beans and corn to transfer and count the seeds. The error ratio of seed metering was less than 3.5%.

  • PDF

A study on the taped banknotes detecting device of banknote counting machine (지폐계수기의 테이프권 검출장치 개발에 관한 연구)

  • Lim, Kyoung-Taek;Won, Si-Tae
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • A conventional taped banknotes detecting device in the banknote counting machine have some problems caused by temperature, humidity, dust and other environmental conditions. In order to the improve the detection performance of taped banknote in the banknote counting machine, we developed taped banknotes detecting device that the ultrasonic wave sensor was replaced by mechanical method device. There are many factors for the performance of the taped banknote detecting device of a mechanical method, we considered three main factors that are the amplification ratio of the thickness of banknotes, the pressing force of banknotes and the feeding speed of banknotes. We carried out the experiments with the 27 kinds of combination of these three main factors. As the result, accurate detection was possible to the normal banknotes and taped banknotes regardless of the feeding rate in terms of the amplification rate 27 times and the pressing force 660gf.

Navigation based Motion Counting Algorithm for a Wearable Smart Device (항법 기반 웨어러블 스마트 디바이스 동작 카운트 알고리즘)

  • Park, So Young;Lee, Min Su;Song, Jin Woo;Park, Chan Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.547-552
    • /
    • 2015
  • In this paper, an ARS-EKF based motion counting algorithm for repetitive exercises such as calisthenics is proposed using a smartwatch. Raw sensor signals from accelerometers and gyroscopes are widely used for conventional smartwatch counting algorithms based on pattern recognition. However, generated features from raw data are not intuitive to reflect the movement of motions. The proposed motion counter algorithm is composed of navigation based feature generation and counting with error correction. The candidate features for each activity are velocity and attitude calculated through an ARS-EKF algorithm. In order to select those features which reveal the characteristics of each motion, an exercise frame from the initial sensor frame is introduced. Counting processes are basically based on the zero crossing method, and misdetected counts are eliminated via simple classification algorithms considering the frequency of the counted motions. Experimental results show that the proposed algorithm efficiently and accurately counts the number of exercises.

Performance Improvement of Smart Counter for Uneven Small Grain (지능형 미소비균일체 계수기의 성능개선)

  • Cho, Si-Hyeong;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.127-131
    • /
    • 2009
  • This paper presents the development of smart counting system that is proper for grains with uneven unit weight or shape. This device can detect the small differences of a light beam and count the pulse from wave shape control, when the grain is going on the light screen, which is made by the light beam screen sensor. It can, different from the former conventional device, distinct the uneven grains for counting detect, by using the dedicated hardware and the software algorithm of the light sensor.

  • PDF

A Micro Cell Counter Integrated with Oxygen Micropump

  • Son, Sang-Uk;Choi, Yo-Han;Lee, Seung-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2441-2444
    • /
    • 2003
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and Sephadex G-25 beads counting experiment. The device utilized a phototransistor, microwindow, and light source of microscope for beads detection. Microheater and microchannel were used for pumping and guiding of beads to the microwindow. Counting capability of the device was tested with a peristaltic pump and the measured signals (${\sim}10\;mV$) with oscilloscope showed peak shape when beads passed the microwindow. Pumping of beads by the oxygen micropump was carried out by heating paraffin, which enveloped manganese dioxide (catalyst), to trigger the decomposition of hydrogen peroxide into water and oxygen. It lasted for 5 min with $7\;{\mu}l$ of wt. 30 % hydrogen peroxide. Beads counting by oxygen micropump showed peaks ($2{\sim}20\;mV$) with $30\;{\mu}l$ of beads sample and the number of peaks by magnitude was acquired.

  • PDF

Beta Gamma Survey Meter (베타 및 감마선 계측용 서어베이 미터)

  • 박인용;이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1971
  • A survey meter which is used a G-M counter sensitive to beta and gamma radiation is studied. This device is completely transistorized, operated with battery, and can be read directly the 3 full-scale meter range: 2.5, 25 and 250 MR/HR respectively. The collector-coupled monostabel multivibrator consisting of a counting-rate meter circuit, and the astable blocking oscillator consisting of a dc-de converter for power supply are analyzed and derived the design dquations. To improve the resolving time of the G-M counter the device is designed to be triggered by low pulse in the order of 0.5v.

  • PDF

The input device system with hand motion using hand tracking technique of CamShift algorithm (CamShift 알고리즘의 Hand Tracking 기법을 응용한 Hand Motion 입력 장치 시스템)

  • Jeon, Yu-Na;Kim, Soo-Ji;Lee, Chang-Hoon;Kim, Hyeong-Ryul;Lee, Sung-Koo
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.157-164
    • /
    • 2015
  • The existing input device is limited to keyboard and mouse. However, recently new type of input device has been developed in response to requests from users. To reflect this trend we propose the new type of input device that gives instruction as analyzing the hand motion of image without special device. After binarizing the skin color area using Cam-Shift method and tracking, it recognizes the hand motion by inputting the finger areas and the angles from the palm center point, which are separated through labeling, into four cardinal directions and counting them. In cases when specific background was not set and without gloves, the recognition rate remained approximately at 75 percent. However, when specific background was set and the person wore red gloves, the recognition rate increased to 90.2 percent due to reduction in noise.

Automated Bacterial Cell Counting Method in a Droplet Using ImageJ (이미지 분석 프로그램을 이용한 액적 내 세포 계수 방법)

  • Jingyeong Kim;Jae Seong Kim;Chang-Soo Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.247-257
    • /
    • 2023
  • Precise counting of cell number stands in important position within clinical and research laboratories. Conventional methods such as hemocytometer, migration/invasion assay, or automated cell counters have limited in analytical time, cost, and accuracy., which needs an alternative way with time-efficient in-situ approach to broaden the application avenue. Here, we present simple coding-based cell counting method using image analysis tool, freely available image software (ImageJ). Firstly, we encapsulated RFP-expressing bacteria in a droplet using microfluidic device and automatically performed fluorescence image-based analysis for the quantification of cell numbers. Also, time-lapse images were captured for tracking the change of cell numbers in a droplet containing different concentrations of antibiotics. This study confirms that our approach is approximately 15 times faster and provides more accurate number of cells in a droplet than the external analysis program method. We envision that it can be used to the development of high-throughput image-based cell counting analysis.