• 제목/요약/키워드: Counting Device

검색결과 70건 처리시간 0.029초

압전필름을 센서로 사용한 접촉식 계수장치 개발 (Development of a Contact-Type Counting Device Using a Piezoelectric Film as a Sensor)

  • 유완동;김진오;박광훈
    • 한국소음진동공학회논문집
    • /
    • 제15권2호
    • /
    • pp.239-247
    • /
    • 2005
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

압전 센서를 사용한 계수 장치 개발 (Development of a Counting Device Using a Piezoelectric Sensor)

  • 유완동;김진오;박광훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1089-1092
    • /
    • 2004
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

  • PDF

자동제어식 파종조절장치 개발 (Development of Automatic Seed Metering Device)

  • 이용국;이대원;오영진
    • Journal of Biosystems Engineering
    • /
    • 제19권2호
    • /
    • pp.91-98
    • /
    • 1994
  • Planting, transplanting, and harvesting are important processes for the successful production of farm products in Korea because those require the high labor intensity during limitted period. Recently, many researches of using automatic control with a microcomputer are carried in the agricultural field, but are not much spread to the seeder development. Automatic sowing technology would be much attractive if there was a way to assure that each seed was count accurately in the seed metering device. Thus, an automatic seed metering device was designed and constructed to be controlled by microcomputer. This device could be improved in not only counting the number of seeds in but also sowing seeds between row spacings. Automatic seed metering device consisted of conveyor belt and temporary storage device. Performance of seed metering device depends on the apparatus including sensor, stepping motor and DC-solenoid. Research contents and results are summarized as follows. 1. The seed metering device involving seed hopper, sorter and temporary storage device was designed and constructed. 2. A seed counting system with six photo electric sensors, designed and built for this project, was adequate for tranferring and counting seeds accurately. 3. Operating algorithm for stepping motor and photo electric DC-solenoid was developed. The Seed metering device proved to be a smooth and accurate operating device using the algorithm. 4. The performance of second prototype metering device was examined with five kinds of seeds ; mung beans, red beans, white beans, black beans and corn to transfer and count the seeds. The error ratio of seed metering was less than 3.5%.

  • PDF

지폐계수기의 테이프권 검출장치 개발에 관한 연구 (A study on the taped banknotes detecting device of banknote counting machine)

  • 임경택;원시태
    • Design & Manufacturing
    • /
    • 제11권1호
    • /
    • pp.19-25
    • /
    • 2017
  • A conventional taped banknotes detecting device in the banknote counting machine have some problems caused by temperature, humidity, dust and other environmental conditions. In order to the improve the detection performance of taped banknote in the banknote counting machine, we developed taped banknotes detecting device that the ultrasonic wave sensor was replaced by mechanical method device. There are many factors for the performance of the taped banknote detecting device of a mechanical method, we considered three main factors that are the amplification ratio of the thickness of banknotes, the pressing force of banknotes and the feeding speed of banknotes. We carried out the experiments with the 27 kinds of combination of these three main factors. As the result, accurate detection was possible to the normal banknotes and taped banknotes regardless of the feeding rate in terms of the amplification rate 27 times and the pressing force 660gf.

항법 기반 웨어러블 스마트 디바이스 동작 카운트 알고리즘 (Navigation based Motion Counting Algorithm for a Wearable Smart Device)

  • 박소영;이민수;송진우;박찬국
    • 제어로봇시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.547-552
    • /
    • 2015
  • In this paper, an ARS-EKF based motion counting algorithm for repetitive exercises such as calisthenics is proposed using a smartwatch. Raw sensor signals from accelerometers and gyroscopes are widely used for conventional smartwatch counting algorithms based on pattern recognition. However, generated features from raw data are not intuitive to reflect the movement of motions. The proposed motion counter algorithm is composed of navigation based feature generation and counting with error correction. The candidate features for each activity are velocity and attitude calculated through an ARS-EKF algorithm. In order to select those features which reveal the characteristics of each motion, an exercise frame from the initial sensor frame is introduced. Counting processes are basically based on the zero crossing method, and misdetected counts are eliminated via simple classification algorithms considering the frequency of the counted motions. Experimental results show that the proposed algorithm efficiently and accurately counts the number of exercises.

지능형 미소비균일체 계수기의 성능개선 (Performance Improvement of Smart Counter for Uneven Small Grain)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.127-131
    • /
    • 2009
  • This paper presents the development of smart counting system that is proper for grains with uneven unit weight or shape. This device can detect the small differences of a light beam and count the pulse from wave shape control, when the grain is going on the light screen, which is made by the light beam screen sensor. It can, different from the former conventional device, distinct the uneven grains for counting detect, by using the dedicated hardware and the software algorithm of the light sensor.

  • PDF

A Micro Cell Counter Integrated with Oxygen Micropump

  • Son, Sang-Uk;Choi, Yo-Han;Lee, Seung-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2441-2444
    • /
    • 2003
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and Sephadex G-25 beads counting experiment. The device utilized a phototransistor, microwindow, and light source of microscope for beads detection. Microheater and microchannel were used for pumping and guiding of beads to the microwindow. Counting capability of the device was tested with a peristaltic pump and the measured signals (${\sim}10\;mV$) with oscilloscope showed peak shape when beads passed the microwindow. Pumping of beads by the oxygen micropump was carried out by heating paraffin, which enveloped manganese dioxide (catalyst), to trigger the decomposition of hydrogen peroxide into water and oxygen. It lasted for 5 min with $7\;{\mu}l$ of wt. 30 % hydrogen peroxide. Beads counting by oxygen micropump showed peaks ($2{\sim}20\;mV$) with $30\;{\mu}l$ of beads sample and the number of peaks by magnitude was acquired.

  • PDF

베타 및 감마선 계측용 서어베이 미터 (Beta Gamma Survey Meter)

  • 박인용;이병선
    • 대한전자공학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 1971
  • G-M 계수관을 이용한 beta와 gamma 선에 민감한 survey meter에 관한 연구이다. 이 장치는 완전 transistor화 되어 있으며 건전지로 동작하게 되어 있고 2.5, 25 및 250MR/HR의 3가지의 full-scale meter range를 직독하게 되어 있다. Counting-rate meter 회로를 이루고 있는 collector 결합 단안정 multivibrator와 전원회로의 de-dc 변환로를 이루고 있는 무안정 blocking 발진기의 해석을 하였고 설계식을 유도하였다. G-M 계수관의 분해시간을 높이기 위하여 0.5v 정도의 낮은 전압으로 triggering할 수 있게 설계하였다.

  • PDF

CamShift 알고리즘의 Hand Tracking 기법을 응용한 Hand Motion 입력 장치 시스템 (The input device system with hand motion using hand tracking technique of CamShift algorithm)

  • 전유나;김수지;이창훈;김형률;이성구
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권1호
    • /
    • pp.157-164
    • /
    • 2015
  • 기존의 대표적인 입력장치는 키보드, 마우스 등으로 한정적이었으나 최근 들어 사용자들의 다양한 요구에 따라 새로운 형태의 입력장치들이 개발되는 추세이다. 이러한 추세에 맞춰 특수한 device 없이 영상의 hand motion을 분석해 명령을 부여하는 새로운 형태의 입력장치를 제안한다. Cam-Shift 기법으로 skin color 영역을 이진화 하여 tracking 한 후, labeling을 통해 분리한 손가락 영역과 손 중심점과의 각도를 동서남북으로 구분해 counting하여 손동작을 인식한다. 손동작에 대한 입력은 맨손에 배경처리를 하지 않은 경우 약 76.8%의 낮은 인식률을 보였으나, 붉은색 장갑을 착용하고 배경을 지정해 줄 경우 잡영 제거의 영향으로 인식률이 90.2%까지 향상된다.

이미지 분석 프로그램을 이용한 액적 내 세포 계수 방법 (Automated Bacterial Cell Counting Method in a Droplet Using ImageJ)

  • 김진경;김재성;이창수
    • Korean Chemical Engineering Research
    • /
    • 제61권2호
    • /
    • pp.247-257
    • /
    • 2023
  • 본 연구에서는 이미지 분석 프로그램을 통해 액적 내 박테리아 세포의 개수를 측정하는 코딩-기반의 자동화된 세포 계수 방법을 제시하였다. 먼저, 형광 이미지 기반의 분석을 위하여, 형광단백질을 발현하는 균주를 담지한 액적을 형성하고 이를 광학 및 형광 현미경을 이용하여 분석 결과를 나타냈다. 액적의 관찰을 용이하게 위하여 유리 그리드에 도포하고, 촬영한 광학 이미지를 통해 분석하고자 하는 영역(Region of Interest)을 지정하였다. 동일한 위치에서 촬영한 형광 이미지에서 앞서 지정된 영역 속 특정 임계 값을 넘는 형광 신호를 계수하여 세포 수를 정량화 하였다. 또한 서로 다른 농도의 항생제를 처리한 액적 내 박테리아의 시간에 따른 세포 개수 변화의 차이를 추적하였다. 30분 간격으로 동일한 위치에서의 형광 이미지들을 동시에 분석함으로써 시간에 따른 세포 개수 변화를 도출하였고, 본 계수법의 성능을 실험적으로 검증하였다. 본 논문의 방법은 외부 분석 프로그램을 이용한 기존 방법 대비 분석 시간을 15배 가량 단축하고, 99%의 정확도를 보이는 것으로 확인되었다. 더 나아가 사용자의 연구의 방향에 맞춰 제시된 코드의 확장 수정을 통해 다양한 종류의 세포 계수 연구에 도움이 될 것으로 기대된다.