• Title/Summary/Keyword: Counter-ion

검색결과 166건 처리시간 0.022초

진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가 (Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments)

  • 안강호;김용민;권용택
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

Effects of the Counter Ion Valency on the Colloidal Interaction between Two Cylindrical Particles

  • Lee, In-Ho;Dong, Hyun-Bae;Choi, Ju-Young;Lee, Sang-Yup
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권3호
    • /
    • pp.567-572
    • /
    • 2009
  • In this study, the effects of counter ion valency of the electrolyte on the colloidal repulsion between two parallel cylindrical particles were investigated. Electrostatic interactions of the cylindrical particles were calculated with the variation of counter ion valency. To calculate the electrical repulsive energy working between these two cylindrical particles, Derjaguin approximation was applied. The electrostatic potential profiles were obtained numerically by solving nonlinear Poission-Boltzmann (P-B) equation and calculating middle point potential and repulsive energy working between interacting surfaces. The electrical potential and repulsive energy were influenced by counter ion valency, Debye length, and surface potential. The potential profile and middle point potential decayed with the counter ion valency due to the promoted shielding of electrical charge. On the while, the repulsive energy increased with the counter ion valency at a short separation distance. These behaviors of electrostatic interaction agreed with previous results on planar or spherical surfaces.

고진공에서 이온 카운터를 사용한 실시간 입자 모니터링 시스템의 개발

  • 안강호;김용민;윤진욱;권용택
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 춘계학술대회
    • /
    • pp.255-258
    • /
    • 2006
  • In this paper, the new method which is monitoring quantity of particles using by ion-counter has been developed. ISPM system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. Ion-counter applied positive voltage could detect only positive charged particles. Therefore charged particles to Boltzmann equilibrium distribution or to some identified charge distribution can be detected by ion-counter. Ion-counter could install on the exhaust line of process equipment since pressure loss is structurally low. ISPM system has been certified by comparison with the result of SMPS (Scanning Mobility Particle Sizer) system. The relation coefficiency is above 0.98 about $20{\sim}300nm$ particles with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

Counter Ion Effect on Photoinduced Electron Transfer Reaction between Ruthenium Complexes

  • Sonoyama, Noriyuki;Kaizu, Youkoh
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.481-486
    • /
    • 1995
  • Quenching experiments by photoinduced electron transfer between a charged donor and a neutral acceptor were carried out in acetonitrile, dichloromethane and mixed solvents of acetonitrile and dichloromethane. Tris(2, 2'-bipyridine) ruthenium(II) ($[Ru(bpy)_3]^{2+}$) which has 2+ charge and dicyanobis (2, 2'-bipyridine) ruthenium(II) ($Ru(bpy)_2(CN)_2$) which has no charge were used as electron donors, and a series of tris(${\beta}$-diketonato) ruthenium (III) was used as acceptor. In dichloromethane, $[Ru(bpy)_3]^{2+}$ and its counter ions ($ClO{_4}^-$) form ion pair. In the estimate of ${\Delta}G$ of electron transfer, the electrostatic potential between counter ions and product ion pair produced by electron transfer must be taken into account. A similar effect of counter ions was found in mixed solvents of 10, 30, 50, 70 and 90% acetonitrile ratio in volume. The effect of counter ion on ${\Delta}G$ became smaller with the increase in acetonitrile ratio. The result in mixed solvents suggests that $[Ru(bpy)_3]^{2+}$ and its counter ions form ion pair even in 90% acetonitrile solution.

  • PDF

Dispersion of Aqueous $Al_2O_3$Suspensions with Electrolytes; Influence of the Counter Ion

  • Cecile Pagnoux;Richard Laucournet;Thierry Chartier;Baumard, Jean-Francois
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.280-285
    • /
    • 2000
  • The electrolyte, $(HO)_2C_6H_2(SO_3Na)_2H_2O $(Tiron), disperses efficiently alumina powder in aqueous media and stable suspensions with 60 vol% solid loading can be prepared. The strong adsorption of this additive is mainly due to the ability of the molecule to form chelate rings with the particle surface but electrostatic interactions between the surface charge and the anionic dispersant strongly influence the amount of Tiron adsorbed. By using a cationic exchange route to substitute the counter ion which neutralizes the sulfonate groups, new molecules of dispersant have been prepared, either with mineral cations as $Li^+,\; Na+^,\; NH_4^\;+$, or with organic cations as counter ion but organic counter ions lead to less to less viscous suspensions than $Na^+$ in particular when the number of carbon atoms of the aliphatic chain increases from 1 to 3.

  • PDF

Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam

  • Hirai, Masaaki;Kanai, Tatsuaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.231-232
    • /
    • 2002
  • We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm$^2$ and 2mm (depth).

  • PDF

The counter-ion effect in surfactant-based remediation

  • 이달희;손양래;서창일;전권호;유순영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.89-91
    • /
    • 2002
  • 본 연구는 소수성 유기물로 오염된 지하수를 복원할경우, 식품등급의계면활성제와 NaOH 또는 NaCl 의 효과를 연구하기 위하여 주상실험을 실시하였다. 실험결과 게면활성제와 NaOH의 혼합 사용이 가장 효과적이었으며, $Na^{+}$의 counter-ion 효과보다는 OH-의 pH효과가 더욱 중요한 인자가 됨이 밝혀졌다.

  • PDF

Importance of The Location of The Negative-charged Counter-ion against The Protonated Schiff Base on The Chromophore Configuration of pharaonis Phoborhodopsin

  • Shimono, Kazumi;Ikeura, Yukako;Sudo, Yuki;Iwamoto, Masayuki;Kamo, Naoki
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.302-304
    • /
    • 2002
  • pharaonis phoborhodopsin (ppR), a photophobic sensor of haloalkaliphilic bacteria, Natronobacterium phar-aonis, has retinal as a chromophore covalently bound to Lys in G-helix via a protonated Schiff base (PSB), as is the same as bacteriorhodopsin (bR). For ppR, the corresponding counter-ion is Asp residue (Asp75) located in C-helix. Here we investigated the influence of the protonated state of this counter-ion and its location on the chromophore configuration. Under alkaline condition, the chromophore configuration of D75E mutant was analyzed by HPLC. D75E had a much larger content of 13-cis isomer: the ratio of 13-cis to all-trans was 6:4 while the wild-type had this ratio of 1 :9. On the other hand, under acidic condition where Glu was associated, D75E had no 13-cis retinal isomer. Mutants whose Asp75 was replaced by neutral amino acids (D75N and D75Q) did not contain 13-cis retinal. Furthermore, retinal isomer compositions and the change in the visible ab- sorption spectra (indicating the dissociation state of Glu75) were measured under varying pH, and these were almost the same dependencies. These results indicate that an important factor determining the 13-cis isomer content is the presence of negative charge of the counter-ion against PSB, but not the size of this residue. Com- parison between the wild-type and D75E in alkaline solutions indicates the influence of the location of the counter-ion.

  • PDF

Fast Protein Staining in Sodium Dodecyl Sulfate Polyacrylamide Gel using Counter ion-Dyes, Coomassie Brilliant Blue R-250 and Neutral Red

  • Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • 제25권5호
    • /
    • pp.704-708
    • /
    • 2002
  • A fast and sensitive protein staining method in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) using both an acidic dye, Coomassie Brilliant Blue R-250 (CBBR) and a basic dye, Neutral Red (NR) is described. It is based on a counter ion-dye staining technique that employs oppositely charged two dyes to form an ion-pair complex. The selective binding of the free dye molecules to proteins in an acidic solution enhances the staining effect of CBBR on protein bands, and also reduces gel background. It is a rapid staining procedure, involving fixing and staining steps with short destaining that are completed in about 1 h. As the result, it showed two to fourfold increase in sensitivity comparing with CBBR staining. The stained protein bands can be visualized at the same time of staining.

유동방향 변화에 따른 고분자 전해질 연료전지의 성능 및 전달특성에 대한 3차원 수치해석적 연구 (Three Dimensional Computational Study on Performance and Transport Characteristics of PEMFC by Flow Direction)

  • 이필형;한상석;황상순
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.51-58
    • /
    • 2008
  • 고분자 전해질 연료전지의 성능향상을 위한 방법으로 유동채널의 형상을 변경한 많은 연구가 진행되어 왔으나 동일한 유동채널 형상에서 유동방향 변경에 따른 연구는 많이 진행되지 못하였다. 본 연구에서는 동일한 반응면적과 동일한 유동채널의 고분자 전해질 연료전지의 수소와 산소의 유동방향을 Co-flow에서 Counter-flow로 변경될 경우의 연료전지의 성능변화를 분석하기 위하여 연료극과 공기극이 포함된 3차원 수치해석모델을 개발하였다. 개발된 수치해석모델을 활용하여 Co-flow와 Counter-flow의 유동채널 내부의 압력손실, 반응물질의 농도분포, 고분자 전해질 막을 통한 Water Transport, 고분자 전해질 막의 이온전도도 및 I-V 성능곡선을 비교하였다. 그 결과 반응물질의 농도분포, Water Transport, 고분자 전해질 막의 이온전도도가 우수한 Counter-flow 유동조건에서의 성능이 Co-flow 유동조건에 비하여 더욱 우수하였다.