• Title/Summary/Keyword: Counter-current

Search Result 452, Processing Time 0.026 seconds

Suitability of Counter-current Model for Biogas Separation Processes using Cellulose Acetate Hollow Fiber Membrane (셀룰로오스 아세테이트 중공사 분리막을 이용한 바이오가스 분리에 대한 향류 흐름 모델의 적용성)

  • Jung, Sang-Chul;Kwon, Ki-Wook;Jeon, Mi-Jin;Jeon, Yong-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.4
    • /
    • pp.43-52
    • /
    • 2020
  • As the membrane gas separation technology grows, various models were developed by numerous researchers to describe the separation process. In this work, the counter-current model was compared thoroughly with experimental data. Experimentally, hollow fiber membrane using CA module was prepared for the separation of biogas. The pure gas permeation properties of membrane module for methane, nitrogen, oxygen, and carbon dioxide were measured. The permeance of CO2 and CH4 were 25.82 GPU and 0.65 GPU, respectively. The high CO2/CH4 selectivity of 39.7 was obtained. the separation test for three different simulated mixed gases were carried out after pure gas test, and the gas concentration of the permeate at various stage-cut were measured from CA membrane module. Results showed that the experimental data agreed with the numerical simulation. A mathematical model has implemented in this study for the separation of biogas using a membrane module. The finite difference method (FDM) is applied to calculate the membrane biogas separation behaviors. Futhermore, the counter-current model can be considered as a convenient model for biogas separation process.

Four Pollution and Safe Measure in Building Demolition (구조물폭파공법 시공시 발파공해 안전대책 - 소음.진동.분진.비석공해를 중심으로 -)

  • 안명석
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.3
    • /
    • pp.91-104
    • /
    • 1993
  • This paper is on the current and prospect of the most advanced explosive technics, special explosive technics. Futhermore, utmost needed and utmost centered interesting basic theory, struction explosive demolition is descirbed with counter Plan on the Problems of carrying out example and cuf out of it. Specified description noted on the four pollution especially noisy vibration, dust and disperse pollution with comprehensive counter plan. Although it has some insufficiency. I expect my paper will be to advance the explosive technics.

  • PDF

On the Pollution & Safe Measure in Building Demolition (구조물폭파의 공해 안전대책 - 소음.진동.분진.비석공해를 중심으로 -)

  • Ahn Myung-Seog
    • Explosives and Blasting
    • /
    • v.11 no.4
    • /
    • pp.9-27
    • /
    • 1993
  • This paper is on the current and prospect of the most advanced explosive technics, Futhermore, utmost needed and centered interesting basic theory, The demolition is described with counter plan on the problems of carrying out example. Specified description noted on the pollution especially noisy, vibration, dust and disperse pollution with comprehensive counter plan. Although it has some insufficiency, 1 expect my paper will be to advance the explosive technics.

  • PDF

Comparison of Counter-Current Cooling and Pool Boiling System Through Modeling and Simulation of a Pilot-Scale Fixed bed Reactor for Dimethyl Ether(DME) Synthesis (Dimethyl Ether(DME) 합성을 위한 파일럿 규모의 고정층 반응기의 모델링과 모사를 통한 향류 냉각방식과 포화액체 풀비등 방식의 비교)

  • Song, Daesung;Go, Jae Wook;Yoon, En Sup
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.446-452
    • /
    • 2009
  • The behavior of a one-step fixed bed reactor which directly synthesizes dimethyl ether(DME) from Natural Gas was simulated. In the reactor, the prevention of the occurrence of hot spots which can cause deactivation of catalysts is pivotal, since methanol synthesis and dehydration reaction involved in the synthesis of DME are highly exothermic. Therefore, we simulated and compared performance of the reactor with counter-current cooling and pool boiling system that can be applied to a commercial plant. As a result, we found that counter-current cooling system is more effective in terms of CO conversion and DME productivity. However, pool boiling system can operate in a small temperature gradient that can decrease problems caused by hot spot. And, the system can operate in a safer range.

Development of Pt-free counter electrode for dye-sensitized solar cell (Pt free 염료감응형 태양전지 전극에 대한 연구)

  • Hwang, Hyun Suk;Park, Yong Seob
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.107-109
    • /
    • 2014
  • Dye-sensitezed solar cell(DSSC) has aroused intense interest owing to its competitive price and stabilized properties than Si based solar cells. Recently, many studies have been reported on the DSSC, especially development of Pt-free counter electrode. In this paper, graphene is chosen counter electrode for low cost material and developed its properties. To estimate the properties of counter electrode, graphene and Pt thin films have been fabricated on FTO substrates respectively, than the films are tested AFM and J-V evaluation method. A graphene of 0.1 wt% has shown current density of 11.68 mA/cm2, maximum efficiency of 4.34% which is similar with that of Pt counter electrode. It confirmed that graphene could be good material for counter electrode if its synthesizing conditions were developed.

High accuracy, Low Power Spread Spectrum Clock Generator to Reduce EMI for Automotive Applications

  • Lee, Dongsoo;Choi, Jinwook;Oh, Seongjin;Kim, SangYun;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.404-409
    • /
    • 2014
  • This paper presents a Spread Spectrum Clock Generator (SSCG) based on Relaxation oscillator using Up/Down Counter. The current is controlled by a counter and the spread spectrum of the Relaxation Oscillator. A Relaxation Oscillator with temperature compensation using the BGR and ADC is presented. The current to determine the frequency of the Relaxation Oscillator can be controlled. The output frequency of the temperature can be compensated by adjusting the current according to the temperature using the code that is the output from the ADC and BGR. EMI Reduction of SSCG is 11 dB, and Spread down frequency is 150 kHz. The current consumption is $600{\mu}A$ from 5V and the operating frequency is from 2.3 MHz to 5.75 MHz. The rate of change of the output frequency with temperature was approximately ${\pm}1%$. The SSCG is fabricated in a 0.35um CMOS process with active area $250um{\times}440um$.

The BASF Laser Optical Pitch Particle Counter - Current Applications and Future Developments

  • Champ Simon;Hughes David;Lee Woo-Suk;Esser Anton;Kaub Hans Peter
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.73-78
    • /
    • 2006
  • The occurrence of detrimental substances in the paper machine leads to reduced economic performance of paper mills through reduced capacities due to increased paper breaks and cleaning times. In this article the latest generation of BASF's laser optical pitch particle counter is employed in the examination of a paper mill operating two paper machines and using a mixture of thermo-mechanical pulp and recycled fibres. The potential of the new instrument to differentiate between particles on the basis of size and chemical composition is discussed. In addition, direct evidence of the periodic and locational variation of detrimental substances in the paper machine is given. Finally, an example of the application of BASF's laser optical pitch particle counter in the selection of a suitable fixative system for a complex furnish is presented.

  • PDF

Micro Cell Counter Integrated with An Oxygen Micropump (산소 미세 펌프가 내장된 미세 세포 계수기)

  • Son, Sang-Uk;Choi, Yo-Han;Lee, Seung-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1159-1165
    • /
    • 2004
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and counting experiment with Sephadex G-25 beads ($70{\sim}100\;{\mu}m$). The pumping part consisted of a microheater, catalyst (manganese dioxide) enveloped with paraffin, hydrogen peroxide, and microchannel, and the counting part consisted of collimated light, a microwindow, and a phototransistor including an external circuit. The micropump generated oxygen gas by decomposing hydrogen peroxide with manganese dioxide, which was initiated by melting the paraffin with the microheater, and pumped beads in the microchannel. When the beads passed the microwindow, they shaded the collimated light and changed the illumination on the phototransistor, which caused the current variation in the circuit. The signals, according to the bead size, reached up to 22 mV with noise level of 2 mV during 50 seconds and the numbers of peaks were analyzed by magnitude.

Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators (암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석)

  • Ji, Je-Hwan;Jeong, Eun-Soo;Jeong, Si-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF