• 제목/요약/키워드: Counter-current

검색결과 452건 처리시간 0.025초

유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성 (Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction)

  • 권경민;정시영;김병주;정은수
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

다공판 유로 내의 유동한계(CCFL)에 대한 실험적 연구 (The Experimental Study on The Counter-Current Flow Limit in The Flow Path with a Porous Plate)

  • 양승우;이진기;권정태;김상녕;강용태
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.156-161
    • /
    • 2007
  • A set of experiments of counter-current flow limit (CCFL) was performed to improve the drawbacks of Wallis' correlation which neglected the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In this study, CCFL was observed by changing the shape of porous plate using air and water. The results show that as the size of porous increases, CCFL with a round shape of the porous plate start to disappear, In this study, the CCFL correlation was calculated and the corresponding CCFL map was developed based on the experimental results.

Effect of Counter-doping Thickness on Double-gate MOSFET Characteristics

  • George, James T.;Joseph, Saji;Mathew, Vincent
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제10권2호
    • /
    • pp.130-133
    • /
    • 2010
  • This paper presents a study of the influence of variation of counter doping thickness on short channel effect in symmetric double-gate (DG) nano MOSFETs. Short channel effects are estimated from the computed values of current-voltage (I-V) characteristics. Two dimensional Quantum transport equations and Poisson equations are used to compute DG MOSFET characteristics. We found that the transconductance ($g_m$) and the drain conductance ($g_d$) increase with an increase in p-type counter-doping thickness ($T_c$). Very high value of transconductance ($g_m=38\;mS/{\mu}m$) is observed at 2.2 nm channel thickness. We have established that the threshold voltage of DG MOSFETs can be tuned by selecting the thickness of counter-doping in such device.

Novel Claw Pole Eddy Current Load for Testing DC Counter Rotating Motor - Part II: Design and Modeling

  • Kanzi, Khalil;Roozbehani, Sam;Dehafarin, Abolfazl;Kanzi, Majid
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.412-418
    • /
    • 2012
  • Eddy current brakes are electromechanical devices used as variable mechanical loads for testing electrical machines. Accurate modeling of eddy current loss is an important t factor for optimum design of eddy brake systems. In this second part, we propose novel formulations of eddy current loss in novel claw-pole eddy brake system. The proposed model for eddy current loss in novel claw-pole eddy brake system depends on the size of the claw poles. Also, in this paper, the flux density is measured by using the magnetic circuit of the novel claw pole. The model results are compared with experimental results and they are found to be in good agreement.

영국의 일반의약품(Over-the-counter drugs) 관리법의 의료정책적 함의 (The NHS Over-the-Counter Drugs Policy in UK: Its Experiences and Implications)

  • 한동운
    • 의료법학
    • /
    • 제12권2호
    • /
    • pp.265-291
    • /
    • 2011
  • Changes in a drug's availability from prescription only to over-the-counter (OTC) status is of concern to physicians from both public health and individual patient perspectives. Government has generally been supportive of changes in medications from prescription(Rx) to over-the-counter (OTC) status in Korea, however, recognizing that there are both benefits and risks to any health care intervention, health care professionals are conservative in implementing changes to either the process or structure of health care. Changes in status of a drug from Rx to OTC can represent a change in both structure and process. Cost and convenience seem to be major factors in determining whether, given the choice, patients purchase a medicine over the counter or obtain it on prescription. With current arrangements, exemption from prescription charges provides an incentive to continue to obtain products on NHS prescription even when they are available over the counter. There is therefore no simple relation between the availability of over the counter medicines and the level of prescribing of deregulated products. The appropriate use of over the counter medicines-particularly those that have only recently been deregulated-places a burden of care on community pharmacists and calls for closer working relationships with general practitioners. In particular, systems for referral and for recording details of both prescribed and over the counter medicines need to be developed, and a direct route needs to be established for community pharmacists to report adverse drug reactions to over the counter products. Reclassification of prescription medicines-by making them available through pharmacies without a prescription-provides the opportunity for consumers to purchase a wider range of medicinal products without making a demand on NHS resources. There is, however, no simple relation between availability of over the counter medicines and demand for NHS prescriptions. In the late 1980s the UK government fuelled the over the counter market by making it easier to reclassify certain medicines from prescription only status to allow over the counter sale in pharmacies. To explore the influence of deregulation of medicines on NHS prescribing, this article presents analyses of consumer behaviour in using medicines and prescribers' attitudes to over the counter medication and collates findings from research. Policy makers should be aware that patients' expectations in relation to OTC medicines may be in conflict with evidence-based practice.

  • PDF

Low Voltage-Driven CNT Cathode and It's Applications

  • Lee, Chun-Gyoo;Lee, Sang-Jo;Cho, Sung-Hee;Chi, Eung-Joon;Lee, Byung-Gon;Jeon, Sang-Ho;Ahn, Sang-Hyuck;Hong, Su-Bong;Choe, Deok-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.851-854
    • /
    • 2004
  • By approaching the counter electrode to the CNT emitter, remarkable reduction of the cathode operating voltage has been accomplished in the under-gate CNT cathode structure. The peak emission current density of 2.5 ms/$cm^2$, which is sufficient for high brightness CNT field emission display, was obtained at the cathode-to-gate voltage of 57 V when the CNT-to-counter electrode gap was 2.2 ${\mu}m$. The gate current was less than 10 % of the anode current. The CNT cathode with low driving voltage can help the cost-effective field emission display implemented.

  • PDF

병렬 공진형 인버터에서 사용되는 새로운 형태의 이산시간 예측 전류 제어기 (A Novel Type of Discrete Time Predictive Current Controllers for Parallel Resonant Inverters)

  • 허성회;최익;김권호;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.309-311
    • /
    • 1996
  • In this paper, we propose two types of novel discrete time current control methods of modified fixed band hysteresis control and optimal control for Parallel Resonant DC Link Inverters(PRDCLI). Because zero bus voltage intervals are generated on the DC link of PRDCLI, we can obtain the information of counter electromotive force(emf) by a simple estimation strategy. The proposed current controllers predict the currents of the next resonant cycle using the obstained information of counter emf and the average values of DC link voltages. The computer simulation results for a simple equivalent circuit of induction motor show that the proposed control methods are more effective than conventional methods.

  • PDF

암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석 (Analysis of Falling-film Generator in Ammonia-water Absorption System)

  • 김병주;손병후;구기갑
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

카운터 기반 디지털 보상 기법을 이용한 위상 고정 루프 (Phase-Locked Loops using Digital Calibration Technique with counter)

  • 정찬희;;이관주;김훈기;김수원
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.320-324
    • /
    • 2011
  • A digital technique is adopted to calibrate the current mismatch of the charge pump (CP) in phase-locked loops. A 2 GHz charge pump PLL (CPPLL) is used to justify the proposed calibration technique. The proposed digital calibration technique is implemented simply using a counter. The proposed calibration technique reduces the calibration time by up to a maximum of 50% compared other with techniques. Also by using a dual-mode CP, good current matching characteristics can be achieved to compensate $0.5{\mu}A$ current mismatch in CP. It was designed in a standard $0.13{\mu}m$ CMOS technology. The maximum calibration time is $33.6{\mu}s$ and the average power is 18.38mW with 1.5V power supply and effective area is $0.1804mm^2$.

등가회로 모델에 의한 레이저다이오드의 누설전류 해석 (Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model)

  • 최영규;김기래
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.330-336
    • /
    • 2007
  • 본 논문에서는 디지털 의료 영상 및 진단 분야 그리고 산업용으로도 활용 가능한 싱글 포톤 계수형 영상센서를 $0.18{\mu}m$ triple-well CMOS(Complementary Metal Oxide Semiconductor) 공정을 사용하여 설계하였다. 설계된 Readout 칩용 싱글 픽셀은 디지털 X-ray 이미지 센서모듈을 간단화 하기 위해 단일 전원전압을 사용하였으며, Preamplifier의 출력 전압인 signal voltage(${\Delta}Vs$)를 크게 하기 위해 Folded Cascode CMOS OP amp를 이용한 Preamplifier를 설계하였으며, 기존의 Readout 칩 외부에서 인가하던 threshold voltage를 Readout 칩 내부에서 생성해 줄 수 있도록 Externally Tunable Threshold Voltage Generator 회로를 새롭게 제안하였다. 그리고, Photo Diode에서 발생하는 Dark Current Noise를 제거하기 위한 Dark Current Compensation 회로를 제안하였으며, 고속 counting이 가능하고, layout 면적이 작은 15bit LFSR(Linear Feedback Shift Resister) Counter를 설계하였다.