• Title/Summary/Keyword: Counter-current

Search Result 452, Processing Time 0.027 seconds

A Novel Claw Pole Eddy Current Load for Testing a DC Counter Rotating Motor Part I: Construction

  • Kanzi, Khalil;Dehafarin, Abolfazl;Roozbehani, Sam;Kanzi, Majid;Vasheghani, Qasem
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.321-329
    • /
    • 2012
  • Providing variable load for testing a motor in high speed conditions is usually a difficult task. The eddy current brake can be used in application of load testing of motors. This paper deals with construction of a novel claw pole eddy current brake which is employed as a load for a DC counter rotating motor (CRM). These kinds of motors have two inner and outer shafts that rotate in opposite directions simultaneously, which are particularly suitable for under water propulsion systems. The prototype 45KW eddy current brake consists of two parts. One of them is installed on the inner shaft of the 60KW DC CRM and the other one is installed on its outer shaft. The simulation and experimental results with prototype brakes are also analyzed by using MATLAB/Simulink and the operational characteristic of the brake is demonstrated as a function of the motor speed and current of the magnetic poles.

Efficiency Improvement of VVCF-Induction Motor Drives with Counter EMF Estimation (역기전력 추정에 의한 VVCF-유도전동기 시스템의 운전효율개선)

  • Moon, Sang-Chun;Lee, Seung-Chul;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.271-273
    • /
    • 1995
  • This paper proposes the efficiency improvement method of vvcf-induction motor drives, which operates always at rated speed, regardless of load conditions, with counter emf estimation. The counter emf is estimated by detecting the fundamental component of motor input current, which is employed in speed control algorithm through the comparison with the actual counter emf during the nonconduction interval. The input power reduction by speed control is confirmed through simulations and experimental results.

  • PDF

Novel Fabrication of Platinum Counter Electrode in Dye-sensitized Solar Cells Using Nano-second Pulsed Laser Sintering

  • Lee, Jin Ah;Yoo, Kicheon;Kim, Woong;Ko, Min Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.234-234
    • /
    • 2013
  • The counter electrodes in dye-sensitized solar cells (DSSCs) play roles in not only collecting electrons from external circuit but also reducing I3- to I- in electrolytes. Generally, conventional counter electrodes for DSSCs are prepared from the high temperature treatment of the H2PtCl6 precursor solution at $400^{\circ}C$ However, the more simplified fabrication process of counter electrodes is required for the commercialization of DSSCs. In this work, we developed novel fabrication process of counter electrodes using nano-second pulsed laser. DSSCs employing counter electrodes prepared by laser process showed conversion efficiency of 6.75% with short-circuit current of 12.73 mA/cm2, open-circuit voltage of 0.74 V and fill factor of 0.72. Closer investigating of photovoltaic properties will be reported.

  • PDF

Visualization of micro-interfacial conditions using Micro PIV

  • OKAMOTO Koji;SHINOHARA Kyosuke;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.111-118
    • /
    • 2004
  • A new micro-resolution PIV (Particle Image. Velocimetry) has been developed. To investigate transient phenomena in a microfluidic device, Dynamic micro-PIV system was realized by combining a high-speed camera and a CW(Continuous Wave) laser. The technique was applied to a micro-counter-current flow, consisting of water and butyl acetate. The velocity fields of water in the micro counter-current flow were visualized for a time resolution of 500 $\{mu}s$ and a spatial resolution of 2.2 x 2.2 $\{mu}m$. Using the Dynamic micro-PIV technique, the vortex-like motions of fluorescent particles at the water-butyl acetate interface were captured clearly

  • PDF

Comparative properties for serial-parallel connection of DSC with CNT and pt counter electrodes (CNT와 Pt 상대전극을 가지는 염료감응형 태양전지의 직렬 ${\cdot}$ 병렬 연결에 따른 특성비교)

  • Choi, Jin-Young;Hong, Ji-Tae;Kim, Mi-Jeong;Lee, Yong-Chul;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.335-338
    • /
    • 2007
  • Cost effectiveness is an important parameter for producing DSSCs as compared to the widely used conventional silicon based solar cells. A fluorine-doped tin oxide (FTO) substrate coated with a catalytic amount of platinum is used as counter electrode in dye-sensitized solar cell. Carbonaceous materials are quite attractive to replace platinum due to their high electronic conductivity, corrosion resistance towards $I_{2}$, good catalytic effect and low cost. In this paper, the unit DSSCs with Pt and CNT as a counter electrode were connected in series-parallel externally, then the current-voltage curves were investigated to find out the connection characteristics of the DSSC with CNT counter electrode. The connection characteristics of the DSSC with CNT counter electrode is superior to that of the DSSC with Pt counter electrode. And a parallel connection of the DSSC with CNT counter electrode has higher efficiency than a series connection of that.

  • PDF

Circuit design of an RSFQ counter for voltage standard applications (전압 표준용 RSFQ counter회로의 설계)

  • 남두우;김규태;김진영;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.127-130
    • /
    • 2003
  • An RSFQ (Rapid Single Flux Quantum) counter can be used as a frequency divider that was an essential part of a programmable voltage standard chip. The voltage standard chip is composed of two circuit parts, a counter and an antenna Analog signal of tens to hundreds ㎓ may be applied to a finline antenna part. This analog signal can be converted to the stream of SFQ voltage pulses by a DC/SFQ circuit. The number of voltage pulses can be reduced by 2n times when they pass through a counter that is composed of n T Flip-Flops (Toggle Flip-Flop). Such a counter can be used not only as a frequency divider, but also to build a programmable voltage standard chip. So, its application range can be telecommunication, high speed RAM, microprocessor, etc. In this work, we have used Xic, WRspice, and L-meter to design an RSFQ counter. After circuit optimization, we could obtain the bias current margins of the T Flip-Flop circuit to be above 31% Our RSFQ counter circuit designs were based on the 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology.

  • PDF

The Opening Efficiency of Anchovy Boat Seine (권현망어구의 전개성능)

  • An, Yeong-Su;Jang, Chung-Sik;Lee, Ju-Hui
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.2
    • /
    • pp.118-131
    • /
    • 1997
  • An opening efficiency experiment of anchovy boat seine has been carried out using a half size of the ordinary seine to reduce the size of the seine net and to improve the fishing efficiency from field operation. The intervals of towing boats were set at 100, 200 and 300m, and the towing speed, at 0.6, 0.9, and 1.2k't by possible combinations of them. The vertical openings of wing net, inside wing net, bagnet and flapper as well as the spreads of the seine net and the towing tension of the warp were measured, to find out efficient fishing gear and method of the anchovy boat seine. The results obtained are as follows : 1. The vertical opening of the inside wing net ranged from 8.7m to 12.0m at the normal current and from 7.0m to 10.0m at the counter current, and that of the wing net, from 8.4m to 19.8m at the normal current and from 4.9m to 16.3m at the counter current. The vertical opening of the wing net and inside wing net decreased as the towing speed and intervals of the boats increase, from 66% to 16% and from 32% to 18% of the normal opening, respectively. 2. The vertical opening of the fore of bag net ranged from 7.9m to 12.8m at the normal current and from 7.4m to 9.7m at the counter current, and that of the flapper, from 3.4m to 5.1m at the normal current and from 4.4m to 5.1m at the counter current, and that of the flapper, from 3.4m to 5.1m at the normal current and from 4.4m to 5.1m at the counter current. The vertical opening of the bag net was from 98% to 57% of the normal opening and the flapper showed a circular shape and it rose up to the upper layer with a slower towing speed. 3. The vertical opening of the end of the bag net ranged from 7.1m to 9.3m at the normal current and from 7.4m to 8.8m at the counter current. The end of the bag net rose up to the upper layer, This phenomenon was more apparent as the towing speed and the interval of the boats increase. 4. The towing tension of the experimental nets increased from 648kg to 2,716kg at the normal current and from 1,050kg to 6,010kg at the counter current with increasing towing speed. 5. The net depth of the anchovy seine was stable with the higher towing speed and the wider interval of the boats, but it was unstable by rising up to the upper layer with the lower towing speed and the narrower interval of towing boats.

  • PDF

Improving Flexibility of External Data Exchange in Count-fire Operation System by Adapting Dynamic Parser Software (동적 구문처리기 소프트웨어 적용을 통한 대화력전 수행체계 연동의 유연성 향상 방안)

  • Hong, Won-Eui
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • The counter-fire operation system performs its mission exchanging information with other related systems such as command & control systems and military information systems. In the process of exchanging information, the counter-fire operation system uses a type of data message which contains exchange data information in the format of KMTF. The requirement of data exchange of count-fire operation will continue to evolve. But the EDX(External Data eXchange) configuration item of the current counter-fire operation system can not effectively cope with the variation of data exchange requirements due to its fixed software structure. In the paper, a solution for improving flexibility of external data exchange in counter-fire operation system is proposed.

A Fault Detection and Self-Recovery System for Space-Borne Dual Ring Counters (우주용 중복구조 링 카운터를 위한 고장 진단 및 자가 복구 시스템)

  • Kwak, Seong Woo;Yang, Jung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.120-126
    • /
    • 2013
  • This paper proposes a novel scheme of fault detection and self-recovery for space-borne dual ring counters subject to transient faults. The considered ring counter is equipped with hardware redundancy, but it has a limited output domain where direct access to the current state is unavailable. We employ the theory of corrective control to detect any transient fault occurring to the counter bits and to realize immediate self-recovery of the ring counter back to the normal state. The structure of the fault-tolerant controller is designed to be minimal regardless of the counter size. To validate the applicability, we implement the proposed system on a commercial FGPA board.

Development of the Lightning Surge Voltage and Current Counters (뇌써지 전압/전류 카운터의 개발)

  • Kil, K.S.;Chang, S.H.;Lee, B.H.;Lee, Y.K.;Lee, B.K.;Ohk, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1882-1884
    • /
    • 1996
  • This paper deals with the lightning surge counter. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. For the purpose of observing the occurrence frequency as a parameter of the amplitude of surge, two type surge counters were designed and fabricated. One is operated by surge currents, and the other is operated by surge voltages. The former consists of current sensor, metal oxide varister (MOV), rectifier, capacitor and electromagnetic counter. The latter consists of rectifier, voltage divider, comparator, photo coupler and counter circuit, and is useful for detecting the surge voltages.

  • PDF