• Title/Summary/Keyword: Counter rotation position

Search Result 13, Processing Time 0.018 seconds

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Analysis on Forces Acting on the Contact Lens Fitted on the Cornea (콘택트 렌즈에 작용하는 힘의 해석)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.1-11
    • /
    • 2002
  • A mathematical model is proposed to analyze the force; acting on the hard contact lens fitted on the cornea. The model incorporates the nonlinear equations and their numerical solution program, based on the formulations of surface tension force arising from the capillary action in the tear-film layer between the lens and cornea. The model simulates how the adhesion between lens and cornea varies according to the base curves and diameters of the lenses. When the spherical lens is fitted on the spherical cornea it is to rotate downward due to the weight of lens itself until it reaches an equilibrium position along the cornea where the counter(upward) moment caused by net force between the upper and lower portion of the periphery of lens. It is found that both the adhesion and displacement of lens along the cornea, where the gravity of lens balances the capillary-induced upward force, increases rapidly as the base curve of lens increases, i.e., as the lens gets flatter, while the increase in the diameter of lenses has resulted in the less increase in the rotation and adhesion. With the base curve and diameters of lenses being remained constant the increase in surface tension of tear film yields the increase in the adhesion between the cornea and lens while the initial rotation of lens is inversely proportional to the surface tension of the tear film.

  • PDF

ANALYSIS OF FACIAL SOFT-TISSUE CHANGES AFTER MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY (하악 전돌증 환자의 하악지 시상 골절단술후 경조직 변화에 따른 안모 연조직 변화 분석)

  • Park, Hee-Dae;Kwon, Tae-Geon;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.1
    • /
    • pp.87-108
    • /
    • 1996
  • This study was intended to perform cephalometric analysis of the facial soft tissue profile after surgical correction of skeletal Class III malocclusion after SSRO in 29 patients (Males 12, females 17). Lateral cephalograms were taken in centric occlusion before and immediate, long term after surgeries. 1. Counter-clockwise rotation of mandible was observed after the surgery, average relapses of mandibular set back were 1.23-1.28mm. The net effects of the mandibular set-back after surgeries were 81.7-82.2%. Because these relapse tendencies may reduce the effects of the surgical outcomes, surgeon must consider these net before the surgical treatment planning. 2. The ratio of horizontal changes of hard tissue to soft tissue at lower lip, mentolabial sulcus, pogonion were 72.7-93.7%, 100.3%, 99.1-102.1% respectively. There were little changes at upper lip position anteroposteriorly. 3. The relationship of upper and lower lips were improved after surgery. Lower lip was posteriorly repostioned and upper lip was flattend and elongated in conjunction with deepening of inferior lobial sulcus. But profile of chin was still prominent after surgery. 4. Hard tissue horizontal changes and tissue vertical changes were significantly correlated with each other and there were reverse correlations with hard tissue vertical changes and soft tissue horizontal changes.

  • PDF