Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Energy Loss of Hydrogen Atom due to Charge Exchange in Neutral Particle Energy Analyzer (중성입자 에너지 분석장치에서 전하교환용 탄소박막에 의한 수소원자의 에너지 손실특성)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.179-187
    • /
    • 1998
  • A neutral particle energy analyzer, which has the carbon stripping foil and the $90^{\circ}$ cylindrical electrostatic deflection plate, was designed and constructed for measuring of ion temperature in plasma. The energy calibration and energy resolution were studied in detail for a hydrogen ion at the $0.5{\sim}3.0\;keV$ energy using a duoplasmatron ion source. An energy of hydrogen ion to the deflection plate voltage at the peak ion count rate could be fitted by the expression $E_{o}(keV)$=3.83V(kV). The measured energy resolution, which was about 2 % at the energy of 3.0 keV and 9 % at the energy of 0.5keV, was better for the increased hydrogen ion energy. For the charge exchanged hydrogen atom due to the carbon stripping foil, the energy calibration, energy loss and resolution were measured to the $0.5{\sim}2.0{\mu}g/cm^{2}$ thickness of the carbon stripping foil. An energy of the charge exchanged hydrogen atom as a function of the deflection plate voltage and carbon foil thickness could be fitted by the expression $E_{o}(keV)=(0.53d+4.4){\cdot}V(kV)$. The energy loss was $0.23{\sim}0.89\;keV $ to the $0.5{\sim}2.0{\mu}g/cm^{2}$ carbon foil thickness and the $0.5{\sim}3.0\;keV$ energy of the incident neutral hydrogen atom, it could be fitted by the expression ${\Delta}E=(0.12d+0.27){\cdot}{E_{o}}^{1/2}(keV)$. The measured energy resolution for the neutral hydrogen atom, which was between 7 % and 35 % in this experiment region, was increased for the increasing neutral hydrogen atom energy and the decreasing carbon stripping foil thickness.

  • PDF

A Suvey on Satisfaction Measurement of Automatic Milking System in Domestic Dairy Farm (자동착유시스템 설치농가의 설치 후 만족도에 관한 실태조사)

  • Ki, Kwang-Seok;Kim, Jong-Hyeong;Jeong, Young-Hun;Kim, Yun-Ho;Park, Sung-Jai;Kim, Sang-Bum;Lee, Wang-Shik;Lee, Hyun-June;Cho, Won-Mo;Baek, Kwang-Soo;Kim, Hyeon-Shup;Kwon, Eung-Gi;Kim, Wan-Young;Jeo, Joon-Mo
    • Journal of Animal Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present survey was conducted to provide basic information on automatic milking system (AMS) in relation to purchase motive, milk yield and quality, customer satisfaction, difficulties of operation and customer suggestions, etc. Purchase motives of AMS were insufficient labor (44%), planning of dairy experience farm (25%), better performance of high yield cows (19%) and others (6%), respectively. Average cow performance after using AMS was 30.9l/d for milk yield, 3.9% for milk fat, 9,100/ml for bacterial counts. Sixty-eight percentage of respondents were very positive in response to AMS use for their successors but 18% were negative. The AMS operators were owner (44%), successor (44%), wife (6%) and company worker (6%), respectively. The most difficulty (31%) in using AMS was operating the system and complicated program manual. The rate of response to system error and breakdown was 25%. The reasons for culling cow after using AMS were mastitis (28%), reproduction failure (19%), incorrect teat placement (12%), metabolic disease (7%) and others (14%), respectively. Fifty-six percentages of the respondents made AMS maintenance contract and 44% did not. Average annual cost of the maintenance contract was 6,580,000 won. Average score for AMS satisfaction measurement (1 to 5 range) was 3.2 with decrease of labor cost 3.7, company A/S 3.6, increase of milk yield 3.2 and decrease of somatic cell count 2.8, respectively. Suggestions for the higher efficiency in using AMS were selecting cows with correct udder shape and teat placement, proper environment, capital and land, and attitude for continuous observation. Systematic consulting was highly required for AMS companies followed by low cost for AMS setup and systematization of A/S.

Changes in Quality Characteristics of Fresh-cut Produce during Refrigerated Storage (냉장 저장 중 신선편이 농산물의 품질특성 변화)

  • Sun, Shih-Hui;Kim, Su-Jin;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.495-503
    • /
    • 2011
  • We evaluated the quality characteristics of fresh-cut produce (potato, sweet potato, carrot, radish, zucchini, cucumber, and green bell pepper) washed with sodium hypochlorite, which were vacuum packaged, and stored at 4 and 10$^{\circ}C$. The L-values of the fresh-cut potato and sweet potato decreased during storage. Lower PPO activities of potato and sweet potato were observed at 4$^{\circ}C$ than those at 10$^{\circ}C$ and development of potato and sweet potato browning was delayed at 4$^{\circ}C$. Total aerobic count and coliform increased continuously at 10$^{\circ}C$ during storage. Diced zucchini and shredded sweet potato had the greatest reduction in hardness among the fresh-cut produce during storage. Differences in the rate of quality change were observed according to the kinds and cut types of produce. Thus, a quality maintenance period for each type of fresh-cut produce must be determined, which will lead to the safe use of fresh cut produce in foodservice establishments.

Quality Attributes of Fresh-Cut Green Onion as Affected by Rinsing and Packaging (절단 대파의 품질특성에 미치는 세척 및 포장재의 효과)

  • Hong, Seok-In;Jo, Mi-Na;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.659-667
    • /
    • 2000
  • Quality attributes of fresh-cut green onion(Allium fistulosum L.) as affected by rinsing and packaging were investigated in terms of flesh weight, color, viable cell counts, sensory properties during storage at $10^{\circ}C$. Fresh green onions were trimmed, cut, and rinsed with cold water(approximately $5^{\circ}C$) as well as chlorine solution(100 mg/L) and then packaged in low density polyethylene film pouches of $63\;{\mu}m$ thickness. Rinsing treatments with cold water or chlorine solution did not significantly influence changes in microbial populations but sensory characteristics, resulting in cut green onions of better visual quality as compared to the control without rinsing. Fresh-cut green onions were also rinsed with cold water and packaged in sealed bags of low density polyethylene films with different thickness(22, 36, $63\;{\mu}m$), and stored at $10^{\circ}C$ for 18 days. Thickness of polyethylene film was a significant factor for microorganisms populations and sensory attributes. Mesophilic aerobic bacterial count after 13 days for the control, packed in punched film bags, was $3.07{\times}10^6}$ CFU/g, while those for samples in hermetically sealed bags ranged only $1.74{\sim}2.02{\times}10^5}$ CFU/g. Gas composition within the sealed packages changed from normal air to about $1.3{\sim}5.4%\;O_2$ and $4.0{\sim}8.0%\;CO_2$ after 13 days of storage. Particularly, the visual sensory quality of cut green onion samples was retained better in polyethylene film bags of $63\;{\mu}m$ thickness(gas transmission rate: 600 $O_2\;mL/day{\cdot}m^2{\cdot}atm;\;2,500\;CO_2\;mL/day{\cdot}m^2{\cdot}atm$) than in the others.

  • PDF

The Effect of Surfactant Therapy for Acute Lung Injury Induced by Intratracheal Endotoxin Instillation in Rats (기관내 내독소 투여로 유발된 흰쥐의 급성폐손상에서 surfactant의 치료효과)

  • Kang, Yun-Jung;Park, Yong-Bum;Jee, Hyun-Suk;Choi, Jae-Chol;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.487-499
    • /
    • 2000
  • Background : Acute lung injury is an hypoxic respiratory failure resulting from damage to the alveolar-capillary membrane, which can be developed by a variety of systemic inflammatory diseases. In this study the therapeutic effects of intra-tracheal pulmonary surfactant instillation was evaluated in the intratracheal endotoxin induced acute lung injury model of a rat. Methods : Twenty Sprague-Dawley rats were divided into 4 groups, and normal saline (2 ml/kg, for group 1) or LPS (5 mg/kg, for group 2, 3, and 4) was instilled into the trachea respectively. Either normal saline (2 ml/kg, for group 1 & 2, 30 min later) or bovine surfactant (15 mg/kg, 30 min later for group 3, 5 hr later for group 5) was instilled into the trachea. The therapeutic effect of intratracheal surfactant therapy was evaluated with one chamber body plethysmography (respiratory frequency, tidal volume and enhanced pause), ABGA, BAL fluid analysis (cell count with differential, protein concentration) and pathologic examination of the lung. Results : Intratracheal endotoxin instillation increased the respiration rate decreased the tidal volume and int creased the Penh in all group of rats. Intratracheal instillation of surfactant decreased Penh, increased arterial oxygen tension, decreased protein concentration of BAL fluid and decreased lung inflammation at both times of administration (30 minute and 5 hour after endotoxin instillation). Conclusion : Intratracheal instillation of surfactant can be a beneficial therapeutic modality as discovered in the acute lung injury model of rats induced by intratracheal LPS intillation. It deserves to be evaluated for treatment of human acute lung injury.

  • PDF

Quality Changes of Minimally Processed Sliced Deodeok (Codonopsis lanceolata) during Storage by Packaging Method (포장방법 차이에 따른 신선편이 슬라이스 더덕의 저장 중 품질 변화)

  • Choi, Duck-Joo;Lee, Yun-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Park, In-Seon;Cha, Hwan-Soo;Youn, Aye-Ree
    • Food Science and Preservation
    • /
    • v.19 no.5
    • /
    • pp.626-632
    • /
    • 2012
  • In this study, the changes that occurred in the quality of minimally processed sliced Deodeok (Codonopsis lanceolata) in relation to the packing method during storage at $7^{\circ}C$ were investigated. The storage tests were conducted for seven days using PE sealing, but PP sealing and vacuum packaging preserved the Deodeok for 14 days. On the seventh day, the vinyl-packaged Deodeok showed a remarkable fall in quality with 4.5 °Brix, but the PP-sealed and vacuum-packaged Deodeok showed slight falls with 6.4 and $6.8^{\circ}Brix$, respectively. The PE- and PP-sealed Deodeok did not show significant differences in texture and moisture content for two days, and the moisture content was highest in the vacuum-packaged Deodeok during storage. In relation to the total viable cell and the coliform count, the vacuum-packaged Deodeok showed the lowest rate of increment during storage, followed by the others. Thus, the bubble-washed and vacuum-packaged minimally processed sliced Deodeok was found to have the best quality.

Comparison of quality changes in brined cabbage with deep sea water salt and a commercial brined cabbage product (해양심층수염 절임배추와 시판 절임배추의 품질변화 비교)

  • Lim, Ji Hoon;Jung, Jee Hee;Kim, Dong Soo;Kim, Young Myoung;Kim, Byoung Mok
    • Food Science and Preservation
    • /
    • v.21 no.5
    • /
    • pp.676-687
    • /
    • 2014
  • This study investigated the quality changes in cabbage brined with deep sea water salt and in a commercial brined cabbage product. The subject cabbages were separated into two groups: those manufactured in the Lab (ML) and the commercial brined cabbage product (CP). Each group had three brining treatments: with sun-dried salt (S, CS), refined salt (R, CR), and deep sea water salt (D, CD). The salinity level of the ML group was 2.1~2.3%, higher than that of the CP group (1.1~1.5%). The total plate count (TPC) was detected as 5.0 log CFU/g with the S, R, and D treatments at Day 7, but the growth rate of the TPC with the CS, CR, and CD treatments was faster than that with the S, R, and D treatments (6.9~7.7 log CFU/g). A lactic acid bacteria (LAB) level of 5.0~6.6 log CFU/g was also detected in the S, R, and D samples, but only 7.0~7.6 log CFU/g was detected in the CP groups at Day 14. The instrumental hardness levels of the cabbage brined with the deep sea water salts (D and CD) were 3,971 g and 3,932.4 g, respectively, which were significantly higher than those of the samples that were salted with sun-dried salt and refined salt (p<0.05). As for the sensory attributes, S, D, and CD maintained their marketability scores until the end of the storage period for all the properties. CD presented the highest total free amino acid (478.9 mg%), glutamic acid (107.0 mg%), citric acid (428 mg%), and sodium (189 ppm) contents.

Analysis of Bronchoalveolar Lavage Fluid cells from the Patients of Diffuse Interstitial Lung Diseases (미만성 간질성 폐질환에서 기관지 폐포세척액내의 세포 검사)

  • Kim,, Hyo-Seok;Moon, Soo-Nam;Cheong, Seung-Whan;Lee, Sang-Moo;Kim, Hyeon-Tae;Lee, Guang-Cho;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik;Jin, Byung-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.604-615
    • /
    • 1994
  • Background: Analysis of cells in bronchoalveolar lavage(BAL) fluid had been used to predict the histologic changes of the bronchioles and alveoli in patients with interstitial lung diseases(ILD). Definitive diagnosis can be a1so made in some cases of ILD, such as histiocytosis. However, there are a few data of the cellular components in BAL fluid in normal Korean individuals and in patients with ILD. In order to evaluate the role of the cellular analysis of BAL fluid in prediction of alveolitis and differential diagnosis among ILDs, we compared the cellular components in BAL fluid from 50 normal individuals and 86 ILD patients. Method: BAL was performed by instillation and retrievement of normal saline with fiberoptic bronchoscopy. The cell number was counted by Hemocytometer. Differential count was done up to 500 cells on slides prepared by Diff-Quik stain and non-specific esterase stain. We compared the recovery rate(RR), cell numbers(CN), and percentages of each cellular components(CP). Results: The results were as follows: 1) There was no difference in RR, CN and CP between the normal smoker group and normal non-smoker group. 2) Total cell numbers recoverd in BAL fluid increased in collagen vascular diseases(CVD), hypersensitivity pneumonitis(HP), idiopathic pulmonary fibrosis(IPF), and miliary tuberculosis(Mil TBC) groups. 3) The percentage of lymphocytes increased in HP, IPF and Mil TBC groups. Macrophage percentages increased in HP, IPF, and Mil TBC groups. Neutrophil percentages were increased in CVD, HP, IPF and Mil TBC groups. Eosinophil percentages were increased in HP, IPF and Mil TBC groups. The numbers of each cells showed same findings as the percentages did. Conclusion: The analysis of cellular components of BAL fluid can predict the presence of alveolitis in many cases of ILDs. However, It was not helpful in differential diagnosis among ILDs.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.