• Title/Summary/Keyword: Count rate

Search Result 869, Processing Time 0.022 seconds

Real-time PCR Quantification of White Spot Syndrome Virus (WSSV) and Hepatopancreatic Parvovirus (HPV) Loads in Shrimp and Seawaters of Shrimp Ponds on the West Coast of South Korea

  • Jang, In-Kwon;Gopalakannan, Ayyaru;Suriakala, Kannan;Kim, Jong-Sheek;Kim, Bong-Rae;Cho, Yeong-Rok;Meng, Xian-Hong;Seo, Hyeong-Chul
    • Fisheries and Aquatic Sciences
    • /
    • v.11 no.4
    • /
    • pp.195-204
    • /
    • 2008
  • Viral diseases are major emerging problems of shrimp that have affected the production, and even complete losses for shrimp farms. In this study, we developed a sensitive TaqMan real-time PCR method to quantify white spot syndrome virus (WSSV) and hepatopancreatic parvovirus (HPV) in the shrimp and pond water in which fleshy shrimp, Fenneropenaeus chinensis, and Pacific white shrimp, Litopenaeus vannamei, are reared. WSSV and HPV in pond seawaters ranged from $1.65{\times}10^3$ to $2.43{\times}10^9$ and from 0 to $4.43{\times}10^5$ copies/L of seawater, respectively. Of 20 ponds analyzed, all pond water and shrimp were positive for WSSv. L. vannamei showed higher susceptibility to WSSV than F chinensis. HPV was detected only in the pond water for F chinensis. In shrimp tissue, however, HPV was found in both species, with 23-times higher infection rate in F chinensis than L. vannamei. The total bacterial counts in the pond water ranged from $2.23{\times}l0^3$ to $1.98{\times}l0^5\;CFU/mL$. The variations in total bacterial count for each pond appeared to correlate to the variations of the WSSV load. Statistical analysis indicated that there was no significant difference (P>0.05) between the WSSV load in pond water and shrimp, and there was no relationship between total bacterial load and viral load in the pond water. However, a significant difference (P<0.01) was found between HPV load and L. vannamei and F chinensis pond water.

The Effects of Sophorae Radix Pharmacopuncture Therapy on the Chunchu(ST25) for DSS-induced Colitis in Rats (천추(天樞)(ST25) 고삼약침(苦蔘藥鍼)이 DSS로 유발된 대장염 백서에 미치는 영향)

  • Yang, Tae Jun;Kim, Kyeong Ok;Kim, Kyeong Su;Park, Su Yeon;Yang, Seung Joung;Choi, Chang Won;Wei, Tung Shuen
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.77-85
    • /
    • 2015
  • Objectives : The purpose of this study is to investigate the effects of Sophorae radix pharmacopuncture(SRP) therapy on the Chunchu($ST_{25}$) on intestinal disease in rats with dextran sulfate sodium(DSS)-induced colitis. Methods : The experimental model of colitis was induced by an infection of DSS for fifteen days. After colitis was induced, SRP therapy was practiced on the Chunchu($ST_{25}$) once every three days for a total of five times. Afterward, colon length, damage to the colonic mucosa, complete blood count, aspartate aminotransferase(AST), alanine transferase(ALT), blood urea nitrogen(BUN), creatinine, TNF-${\alpha}$ and IL-6 were measured. Results : The results were obtained as below. 1. Colon length was significantly increased in the SRP group 2 compared to the control group. 2. Damage of colonic mucosa was observed less in the SRP groups than in the other groups. 3. The mean rates of white blood cell(WBC), neutrophils and lymphocytes were significantly increased in SRP group 2 compared to the control group. 4. The mean rates of HGB and hematocrit(HCT) were significantly increased in the SRP compared to the control group. 5. No significant differences were shown in AST, ALT, BUN and Creatinine between the SRP groups and the control group. 6. The mean rate of TNF-${\alpha}$ was significantly decreased in the SRP groups compared to the control group. 7. The mean of IL-6 was significantly decreased in the SRP groups compared to the control group. Conclusions : These results indicated that SRP therapy on Chunchu($ST_{25}$) functions as a treatment to the dextran sulfate sodium-induced colitis.

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

CONSTRUCTION OF RECOMBINANT HSCC-1 ADENOVIRUS VECTOR FOR ORAL CANCER GENE THERAPY (구강암 유전자 치료를 위한 재조합 HSCC-1 아데노바이러스의 개발)

  • Kim, Chang-Hyen;Kim, Jin-Woo;Kim, Myung-Jin;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.103-109
    • /
    • 2005
  • In spite of the ongoing advances, standard therapies for oral cancer still has some limitations in efficacy and in ability to prolong survival rate of advanced disease and result in significant functional defect and severe cosmetic deformity. Currently gene therapy using tumor suppressor gene is considered as a potent candidate for new therapeutic approaches that can improve efficacy and reduce complications. The purpose of this research is to identify the role of adenoviral vector to transfer HCCS-1 tumor suppressor gene in oral cancer cells and to find out whether there is a possibility for it to serve in the field of gene therapy. The human SCC-25 cell line was used for transfection. To determine the efficiency of the adenovirus as a gene delivery vector cell line was transduced with LacZ gene and analysed with X-gal staining. Northern blot was performed to confirm the tranfection with HSCC-1 gene and cell viability was assessed by cell cytotoxicity assay. We had successfully construct the recombinant HSCC-1 adenovirus(Ad5CMV-HCCS-1). DNA extracted from Ad5CMV-HCCS-1 revealed HCCS-1 gene is incorporated. The transduction efficiencies were over than 50% of SCC-25 cells with a MOI of 2 and over 95% with a MOI of 50. Northern blot analysis showed that a single 0.6kb mRNA transcript was expressed in Ad5CMV-HCCS-1 transduced SCC-25 cells. There was no or very low transcription HCCS-1 mRNA in wild and Ad5CMV-LacZ transduced SCC-25 cells. Cells transduced with Ad5CMV-HCCS-1 showed significant growth inhibition. By day 6, Ad5CMV-HCCS-1 treated cell count was decreased to 30% of mock-infected cells, while that of Ad5CMV-LacZ treated cells was 90% of mock-infected cells (p<0.05). Finally, these result suggest that the Ad5CMV-HCCS-1 has potential as a gene therapy tool for oral cancer.

Preservatory Effect of Sweet Persimmons, Mandarin Oranges and Apples Stored in the Ear-Infrared Radiated Chamber (원적외선 방사체 시설내에 저장한 단감, 감귤 및 사과의 선도유지효과)

  • 정준호;조성환
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.435-440
    • /
    • 2003
  • Such fruits as nut persimmons, mandarin oranges and apples stored in the far-infrared radiated chamber at 5$^{\circ}C$ under 90% of relative humidity had been maintained in the fresh state for longer times than the control stored only in the cold chamber. Fruits stored in the far-infrared radiated chamber showed lower values in weight loss rate, microbial colony count and decay ratio and higher ascorbic acid content than the control stored only in the told room through the storage period. We confirmed that fruits stored in the far-infrared radiated chamber under low temperature and high humidity showed least changes in quality properties through the storage period and the far-infrared radiated facilities could be a good storage system.

Changes in Quality Properties of Cherry Tomatoes, Cucumbers and Zuchinis Stored in the Ear-Infrared Radiated Chamber Equipped with Autoclaved tight Weight Concrete (원적외선 방사체인 경량기포콘크리트 시설내에 저장한 방울토마토, 오이 및 호박의 품질특성 변화)

  • 정준호;조성환
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.441-446
    • /
    • 2003
  • Cherry tomatoes, cucumbers and zuchinis stored in the far-infrared radiated chamber at 5$^{\circ}C$ or 10$^{\circ}C$ under 90% of relative humidity had been maintained in the fresh state for longer times than the control stored only in the cold chamber. Vegetables stored in the far-infrared radiated chamber showed lower values in weight loss rate, microbial colony count and decay ratio and higher ascorbic acid content than the control stored cold in the cold room through the storage period. We confirmed that vegetables stored in the far-infrared radiated chamber under low temperature and high humidity showed least changes in quality properties through the storage period and the far-infrared radiated facilities could be a good storage system.

Changes of Postharvest Quality and Microbial Population in Jujube-Shaped Cherry Tomato (Lycopersicon esculentum L.) by Stem Maintenance or Removal (수확 후 꼭지 유지, 제거에 따른 대추형 방울토마토의 품질 및 미생물 변화)

  • Choi, Ji Weon;Lee, Woo Moon;Do, Kyung Ran;Cho, Mi Ae;Kim, Chang Kug;Park, Me Hea;Kim, Ji Gang
    • Food Science and Preservation
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 2013
  • Red-ripe 'Betatiny' jujube-shaped cherry tomato fruits via stem maintenance or stem removal were stored at $20^{\circ}C$ for 12 days. Their quality and microbial safety parameters like their respiration rate, weight loss, soluble solids content (SSC), titratable acidity (TA), firmness, hue value, aerobic microflora, coliform, yeast and mold count, and decay were evaluated during their storage. The jujube-shaped cherry tomato fruits whose stems were removed lost less weight than the fruits whose stems were maintained during their 12 days of storage. The stem removal lowered the respiration more significantly than the stem maintenance, and the formation of novel tissues at the stem scar that resulted from the stem removal was observed morphologically. The SSC, TA and hue value of the skin color decreased after eight storage days, but showed no difference between the stem maintenance and removal. The stem had higher microbial counts like aerobic microflora, coliform, and yeast and mold counts. The stem maintenance showed a short shelf-life because molds grew on the attached stem after five storage days. The shelf-life of the jujube-shaped cherry tomato fruits whose stems were removed was about eight days, but that of the fruits whose stems were maintained and that were stored at $20^{\circ}C$ was only about six days.

Effect of a Combinacon of Mental Activity with Experimental Subway Noise on Hematology (실험적 지하철 소음에서의 지적활동이 혈액생리에 미치는 영향)

  • Choi, Seok-Cheol;Hyun, Kyung-Yae;Park, Jae-Hyun;Kwon, Heun-Young
    • Journal of Life Science
    • /
    • v.16 no.7 s.80
    • /
    • pp.1174-1180
    • /
    • 2006
  • The present study was sought to clarify whether the combination of mental activity with subway noise affects hematological variables. Fifty-six healthy volunteers participated in this experiment and underwent a stress task consisting of combination_of mental activity (mental arithmetic) with subway noise for 50 min and 60min of recovery after the end of the stress task. Venous blood samples were collected for measuring CBC, prothrombin time (PT), activated partial thromboplastin time (aPTT), erythrocyte sedimentation rate (ESR), fibrinogen concentration, D-dimer and high sensitive C-reactive protein (H-CRP) levels before (baseline), 50min of stress task (S-50m), and 60 min of recovery (R-60m). Total leukocyte, neutrophil and lymphocyte counts significantly increased at R-60m compared with baselines. RBC count at S-50m was higher, while monocyte counts at S-50m and R-60m were lower than those of baselines. aPTTs shortened at S-50m and R-60m, but PT reduced at R-60m as compared with baselines. D-dimer and H-CRP levels at S-50m and R-60m were significantly higher than those of baselines. These findings imply that a combination of mental activity with subway noise nay cause leukocytosis, homo-concentration, shortened PT and aPTT, decreased ESR, and raised D-dimer and H-CRP levels, suggesting possible development of inflammation and prothrombogenic reaction attributable to a subway environment.

Failure Analysis of Corroded Coating Materials by Acoustic Emission (음향방출법에 의한 용사코팅 피막부식재의 파손 해석)

  • KIM GUI-SHIK;HYUN CHANG-HAE;HONG YONG-UI;SHON CHANG-HWAN
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.43-49
    • /
    • 2005
  • This paper is to investigate the effect of corrosion by acoustic emission method in tensile loading and the adhesiveness between substrate and coating layer. The powders used are Zn and Amdry625, respectively. They are coated on brass alloy substrate. AE signals of Zn and Amdry625 coating layer increase drastically in strain $2\%$. However, those of Zn specimen have more than those of Amdry625 specimen. When the specimens executed the corrosion test under $3.5\%$ NaCl solution for 500, 1000 hours, the salt solution penetrated into the surface of the substrate through the pores of the coating layer. As a result, corrosion production formed on the surface of the substrate. The adhesiveness between coating layers is weakened by the polarization and corrosion itself. The AE event, count, and energy of corroded coating specimens decrease, compared to specimens without corrosion. The results are summarized as follows : 1. In the tensile tests, the time that it took to start and develop the cracks and exfoliations between the surface of the substrates and the plasma spray coatings were different according to the type of plasma sprayed material, which are Zn and Amdry625. These phenomena were obvious at the strain rate 1 to $5\%$, and few available data were found after that stage. 2. The specimens with Zn coating showed the characteristics of crack, according to the changes of the tensile strength applied on the substrates while those with Amdry625 showed exfoliation as a result of low adaptation to the tensile strength. 3. The anti-corrosion specimens showed that the adhesive properties between the substrate and the plasma spray coating were strong in the order of Zn, Amdry. It showed that Corroded specimens cracked or exfoliated easily, even with the small energy, because those had a comparatively weakened adhesive property, due to corrosion. 4. Zn specimen showed no corrosion phenomena on the surface of the substrates, because they had the function of sacrifice anode however, Amdry625 specimen showed the corrosion, because it did not have that function.

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF