A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding (보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의)

  • Kwak, Joo-Sik;Shim, Jeong-Woon;Shim, Eung-Bo;Choi, Jong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

Fabrication of computer-interfaced photon counter for single molecule detection in solution (용액내 단일 분자 검출을 위한 컴퓨터 인터페이싱 광자계수기의 제작)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.42-46
    • /
    • 1997
  • In order to acquire the fluorescence burst signals emitted from single dye molecules that pass through a detection space defined by a confocal microscope, a computer-interfaced photon counter has been fabricated. The maximum count rate is about 80 MHz, which is limited by the counter devices used. Using both the operating computer program written by BASIC and the 486 PC computer, the minimum bin-width of 25 $mutextrm{s}$ has been achieved. The characteristics of fluorescence burst signals emitted from JA22 molecules at about 1$\times$$10^{-11}$m mol/L in ethylene glycol are discussed briefly.

  • PDF

IO BOARD DESIGN OF NEXT GENERATION SATELLITE USING THE SPACE WIRE INTERFACE

  • Kwon Ki-Ho;Kim Day-Young;Choi Seung-Woon;Lee Jong-In
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.223-226
    • /
    • 2004
  • This paper presents a feasibility study of an advanced IO board design for the next generation of low-earth orbit satellites. Advanced IO board design includes sensor interface, NO, D/A, Digital Module, Serial Module etc, and allows to process increasing data rates between IO board and CPU board. The higher data rate involved in modem IO board additionally introduce issues such as noise, fault tolerance, command and data handling, limited pin count and power consumption problems. The experience in KOMPSAT-l and 2 program with this kind of problems resulted in using SMCS chip set, a high speed serial link technology based on IEEE-1355 (Space Wire Protocol) (ESA-ESTEC 2003, Parkes 1999), as a standard for next generation of satellite IO board design.

  • PDF

Efficacy of Anthelmintic According to Guide for Fasciola spp. Infected Cattle( III ) (간질방제에 대한 지도효과( III ))

  • 손봉환;황현순;한태호
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 1992
  • For evaluation on effects guiding fasciola prevention of which the specimens collected from 6,011 cows rears at 387 farms in inchon were tested to egg count examination for 4 years(1987-1990), and the questionnaire checked up 181 dairy farms for 2 years (1989-1990). The results were summarized as follows. 1. A yearly variation of fasciola infection rate above 31% were 83% In 1987, 58% in 1988, 25% in 1989, noninfection in 1990. 2. The average concentration in feces of infected dairy cattle was 79.4% below 1-10 eggs for 4 years(1987-1990) 3. In the results of the questionnaire for 2 years(1989-1990) the farmers gradually took interest in fasciola prevention. 4. To re-dose anthelmintics was 75.4% in 1989 and 82.5% in 1990 after 5∼7 months from previous dosage.

  • PDF

Do ancient people have 9 breaths per minute respiratory rate? (고인들은 1분에 9회 빈도의 호흡을 하였는가? : "일만삼천오백식(一萬三千五白息)"에 대한 고찰)

  • Kim, Kiwang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Objectives Some major Chinese medical classics like Huangdineijing (黃帝內經) and Nanjing (難經) assert that a normal person breaths 13,500 times every day. It's just half of real breathing cycles of human. So I tried to find a reasonable explanation to solve this conflict between truth and literal description. Materials and methods To find breath count descriptions in Chinese ancient books, I used Kanseki Repository (http://kanripo.org/). To find precedent research on this topic, I used China National Knowledge Infrastructure (http://cnki.net). Results 33 books refers to human breath cycles for a day, and most of them introduce 13,500 as human breathing frequency of one day. Some recent papers on Laoguanshan (老官山) Western Han dynasty manuscripts show new clues on this topic. Conclusion I assume that 13,500 cycles, the incorrect human breathing frequency of a day, might be originated from adjusting the meaning and usage of the word "Xi (息)".

Detection of Ultrasonic Signals Associated with Tree Growth in Epoxy resin (애폭시수지의 트리성장에 따른 초음파 신호검출)

  • 이상우;송현직;이광식;이동인;김인식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.285-288
    • /
    • 1998
  • Ultrasonic signal characteristics related with the growth of electrical trees in epoxy resin are examined under 67[Hz] ac voltage application along with a CCD camera and PD current method. The ultrasonic sensor with a resonant frequency of 200[Hz] supported by a mechanical spring is attached directly to the lower-side of plane electrode. The magnitude of Partial discharge and count rate of ultrasonic signals have been measured according to the tree growth from a needle tip in an epoxy sample.

  • PDF

Acoustic Emission and Fracture Process of Hybrid HPFRCCs with Polyethylene Fiber and Steel Cord (PE 섬유와 강섬유를 사용한 하이브리드 HPFRCCs의 파괴특성 및 음향방출특성)

  • Kim, Sun-Woo;Jeon, Su-Man;Kim, Yong-Cheol;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.253-256
    • /
    • 2006
  • The HPFRCCs show the multiple crack and damage tolerance capacity due to the interfacial bonding of the fibers to the cement matrix. For practical application, it is needed to investigate the fractural behavior and of HPFRCCs and understand the micro-mechanism of cement matrix with reinforcing fiber. The objectives of this paper are to examine the compressive behavior, fracture and damage process of HPFRCC by acoustic emission technique. Total four series were tested, and the main variables were the hybrid type, polyethylene (PE) and steel cord (SC), and fiber volume fraction. The damage progress by compressive behavior of the HPFRCCs is characteristic for the hybrid fiber type and volume fraction. And from acoustic emission (AE) parameter value, it is found that the second and third compressive load cycles resulted in successive decrease of the ring-down count rate as compared with the first compressive load cycle.

  • PDF

Production of Retort Food using Soybean Curd Residue (비지를 이용한 Retort Food의 제조)

  • Chun, Kie-Hwan;Kim, Byung-Yong;Hahm, Young-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1327-1332
    • /
    • 1998
  • The optimum thermal condition of retort Biji product was determined by heat penetration curve, aerobic bacteria count and sensory test. Retort Biji showed a simple logarithmic heating curve regardless of solid content. Heating time was a $26{\sim}27$ min until Fo value reached 9 min and the amount of microorganism in the Biji product sterilized for 26 min at $121^{\circ}C$ were decreased to $10^{-4}\;CFU/g$, indicating the safe range for retort product. The rate of heat penetration was reduced as solid content and size of product were increased, whereas sterilization temperature and initial temperature of product influenced the heat penetration curve. Sensory scare indicated that there was no significant difference in color, flavor, and appearance among different thermal processes. However, Biji product sterilized at $121^{\circ}C$ showed the highest score in overall preference value.

  • PDF

An Efficient Interpolation Hardware Architecture for HEVC Inter-Prediction Decoding

  • Jin, Xianzhe;Ryoo, Kwangki
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.2
    • /
    • pp.118-123
    • /
    • 2013
  • This paper proposes an efficient hardware architecture for high efficiency video coding (HEVC), which is the next generation video compression standard. It adopts several new coding techniques to reduce the bit rate by about 50% compared with the previous one. Unlike the previous H.264/AVC 6-tap interpolation filter, in HEVC, a one-dimensional seven-tap and eight-tap filter is adopted for luma interpolation, but it also increases the complexity and gate area in hardware implementation. In this paper, we propose a parallel architecture to boost the interpolation performance, achieving a luma $4{\times}4$ block interpolation in 2-4 cycles. The proposed architecture contains shared operations reducing the gate count increased due to the parallel architecture. This makes the area efficiency better than the previous design, in the best case, with the performance improved by about 75.15%. It is synthesized with the MagnaChip $0.18{\mu}m$ library and can reach the maximum frequency of 200 MHz.

Clinical Analysis of Bjork-Shiley Mechanical Valve Replacement (Bjork-Shiley 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.22 no.3
    • /
    • pp.393-401
    • /
    • 1989
  • Between Dec. 1984, and May, 1988,96 prostheses were implanted in 80 patients at Dept. of Thoracic k Cardiovascular Surgery of National Medical Center. 43 patients had mitral valve replacement, 21 underwent aortic valve replacement, and 15 had double valve replacement [Mitral k Aortic], and 1 had tricuspid valve replacement. Seventy-one cases [88.8 %] were in NYHA Class III or IV. The mean duration of follow up was 22.1 months and follow-up information was available for 74 [92.5 %] of the patients. The overall actuarial survival rate at 45 months was 93.05 % and overall hospital mortality was 10 %, late Mortality was 5 %. The linearlized incidence of thromboembolism [2.4%/pt-yr], thrombotic valve obstruction [1.6 %/pt-yr], anticoagulant related bleeding [0.8 %/pt-yr]. There were no fatal valve related complications. The blood was studied in 40 patients 1 year after valve operation. Hgb and reticulocyte count were within normal values and Serum LDH value was slightly elevated but it was not of clinical significance. In conclusion, Monostrut Bjork-Shiley valve prosthesis to be a reliable valve substitute with an acceptable incidence of complications.