• Title/Summary/Keyword: Count rate

Search Result 862, Processing Time 0.028 seconds

A Simple Temperature Dependent Model to Predict the Bloom of Aurelia Aurita Polyps (보름달물해파리 폴립의 대량출현 예측을 위한 온도 종속 모델)

  • Jin, Hong Sung;Oh, Choon Young;Choi, Il Soo;Hwang, Doo Jin;Yoon, Yang Ho;Han, Dong Yeob
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.336-342
    • /
    • 2014
  • Asexual benthic polyp reproduction plays a major role in the jellyfish bloom. Recent studies found that temperature is the most important factor to regulate the budding rate of the polyps. We established a simple dynamic model to count the number of polyps depending on the variation of temperature with two data sets from different places. The population of polyps was counted through the budding rate and the number of budding times by Fibonacci sequence. It is assumed that the budding rate depends on the temperature only. The budding rate of the asexual reproduction shows very sensitive to the distribution of the seawater temperature. The model was tested to the temperature data of Ansan located in the west sea of Korea. The results indicate that this model can be useful to predict the blooms of Aurelia aurita polyps, which may have considerable influence on the bloom of medusa. The shape of temperature curve plays a key role in the predicting the bloom of Aurelia aurita polyps.

Development of a Computer Vision System to Measure Low Flow Rate of Solid Particles (컴퓨터 시각에 의한 고형 입자의 소량 유동율 측정장치 개발)

  • 이경환;서상룡;문정기
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.481-490
    • /
    • 1998
  • A computer vision system to measure low flow rate of solid particles was developed and tested to examine its performance with various sized 7 kinds of seeds, perilla, mung bean, paddy, small red bean, black soybean, Cuba bean and small potato tuber. The test was performed for two types of particle flow, continuous and discontinuous. For the continuous flow tested with perilla, mung bean and paddy, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method about 0.98. Average errors of the computer vision measurement were in a range of 6∼9%. For the discontinuous flow tested with small red bean, black soybean, Cuba bean and small potato tuber, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method 0.98∼0.99. Average errors of the computer vision measurement were in a range of 5∼10%. Performance of the computer vision system was compared with that of the conventional optical sensor to count particles in discontinuous flow. The comparison was done with black soybean, Cuba bean and small potato tuber, and resulted that the computer vision has much better performance than the optical sensor in a sense of precision of the measurement.

  • PDF

A Synthetic Chart to Monitor The Defect Rate for High-Yield Processes

  • Kusukawa, Etsuko;Ohta, Hiroshi
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Kusukawa and Ohta presented the $CS_{CQ-r}$ chart to monitor the process defect $rate{\lambda}$ in high-yield processes that is derived from the count of defects. The $CS_{CQ-r}$ chart is more sensitive to $monitor{\lambda}$ than the CQ (Cumulative Quantity) chart proposed by Chan et al.. As a more superior chart in high-yield processes, we propose a Synthetic chart that is the integration of the CQ_-r chart and the $CS_{CQ-r}$chart. The quality characteristic of both charts is the number of units y required to observe r $({\geq}2)$ defects. It is assumed that this quantity is an Erlang random variable from the property that the quality characteristic of the CQ chart follows the exponential distribution. In use of the proposed Synthetic chart, the process is initially judged as either in-control or out-of-control by using the $CS_{CQ-r}$chart. If the process was not judged as in-control by the $CS_{CQ-r}$chart, the process is successively judged by using the $CQ_{-r}$chart to confirm the judgment of the $CS_{CQ-r}$chart. Through comparisons of ARL (Average Run Length), the proposed Synthetic chart is more superior to monitor the process defect rate in high-yield processes to the stand-alone $CS_{CQ-r}$ chart.

Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator (광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

Intrusion Detection System for In-Vehicle Network to Improve Detection Performance Considering Attack Counts and Attack Types (공격 횟수와 공격 유형을 고려하여 탐지 성능을 개선한 차량 내 네트워크의 침입 탐지 시스템)

  • Hyunchul, Im;Donghyeon, Lee;Seongsoo, Lee
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.622-627
    • /
    • 2022
  • This paper proposes an intrusion detection system for in-vehicle network to improve detection performance considering attack counts and attack types. In intrusion detection system, both FNR (False Negative Rate), where intrusion frame is misjudged as normal frame, and FPR (False Positive Rate), where normal frame is misjudged as intrusion frame, seriously affect vechicle safety. This paper proposes a novel intrusion detection algorithm to improve both FNR and FPR, where data frame previously detected as intrusion above certain attack counts is automatically detected as intrusion and the automatic intrusion detection method is adaptively applied according to attack types. From the simulation results, the propsoed method effectively improve both FNR and FPR in DoS(Denial of Service) attack and spoofing attack.

Producing Top LIS Journal Paper List Based on the Yearly Citation Growth Rate (연간 인용 횟수 증가율에 기반한 문헌정보학 학술지 논문 목록의 순위화에 관한 연구)

  • Kim, Eungi
    • Journal of Korean Library and Information Science Society
    • /
    • v.49 no.2
    • /
    • pp.245-266
    • /
    • 2018
  • This study proposes a novel method to rank highly-cited papers that incorporate the likelihood of receiving future citations. Instead of using the total citation count, the proposed method ranks most-papers based on the yearly citation growth rate (YCGR). The rank of YCGR can be obtained by calculating the average ranks of five individual citation related variables: 1) Total Citation Count, 2) Leftside-Slope, 3) Publication Year, 4) Peak Year, and 5) Rightside-Slope. To empirically test the proposed method, yearly citation counts with other relevant bibliographic records of the 50 most-cited papers in Library and Information Science (LIS) journals used in the study conducted by Walters and Wilder were collected from the Scopus database for the years 1996 to 2016. The result indicated that the YCGR appears to reflect the degree to which the paper is likely to receive future citations, and the ranked list based YCGR offered an alternative viewing feature of the highly-cited papers in LIS. Although more empirical analyses are needed, the rank based on YCGR in conjunction with variables related to YCGR can be used as an alternative method in recognizing influential papers in LIS.

Test turnaround Time for Complete Blood Cell Count using Delta and Panic Value Checks and the Q-flag Limit

  • Koo, Bon-Kyung;Ryu, Kwang-Hyun;Lim, Dae-Jin;Cho, Young-Kuk;Kim, Hee-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.66-74
    • /
    • 2012
  • Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) processed around 10% and 1 unit of ADVIA-2120 (Siemens AG, Munich, Germany) processed around 10%. We analyzed the change in the TAT for the CBC for over 7 years, from January of 2005 to December of 2011. The delta check made alterations of delta to WBC, hemoglobin, hematocrit, platelet and metamyelocyte, however, did not made them to band neutrophil, eosinophil, basophil and monocyte. The panic value check made alterations of panic value to hemoglobin, hematocrit, platelet and monocyte. In the criteria of currently slide review, LH-780 and ADVI-2120 analyzers prepared suspect flags of "Blast, Imm NE2, Immature granulocyte, Imm NE1, Left shift, Variant lymphocyte, Atypical lymphocyte, Platelet clumps and NRBC". The New slide review in the XE-2100 analyzer altered the preparations of a smear slide more than a "Platelet clumps flag(${\geq}200unit$), a single flag excluding the "Platelet clumps flag (${\geq}250unit$) and a multiple flag (${\geq}200unit$)". Also, below the 240 unit, medical technologists prepared manual slides selectively according to their evaluations. The automatic reporting rate was 33.4% without alterations, whereas it was 41.0% without alterations, and was thus improved by 7.6%. The slide review rate was 15.2% before using the Q-flag limit, whereas it was 12.1% for a reduce 3.1%. TAT was 45 minutes without the creation alterations of the delta and panic value checks, whereas it was 35 minutes after making alterations of the delta and panic value checks and thus was shortened by 10 minutes. We came to the conclusion that the establishment and operation of delta and panic value checks and slide review criteria suitable for laboratory environment can reduce unnecessary smear slides, re-checking, re-sampling, re-testing, telephone inquiries and concentrated workloads during specific times of the day.

  • PDF

Development of a parking control system that improves the accuracy and reliability of vehicle entry and exit based on LIDAR sensing detection

  • Park, Jeong-In
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.9-21
    • /
    • 2022
  • In this paper, we developed a 100% detection system for entering and leaving vehicles by improving the detection rate of existing detection cameras based on the LiDAR sensor, which is one of the core technologies of the 4th industrial revolution. Since the currently operating parking lot depends only on the recognition rate of the license plate number of about 98%, there are various problems such as inconsistency in the entry/exit count, inability to make a reservation in advance due to inaccurate information provision, and inconsistency in real-time parking information. Parking status information should be managed with 100% accuracy, and for this, we built a parking lot entrance/exit detection system using LIDAR. When a parking system is developed by applying the LIDAR sensor, which is mainly used to detect vehicles and objects in autonomous vehicles, it is possible to improve the accuracy of vehicle entry/exit information and the reliability of the entry/exit count with the detected sensing information. The resolution of LIDAR was guaranteed to be 100%, and it was possible to implement so that the sum of entering (+) and exiting (-) vehicles in the parking lot was 0. As a result of testing with 3,000 actual parking lot entrances and exits, the accuracy of entering and exiting parking vehicles was 100%.

A study on the contamination level of pathogenic microorganisms in beef distribution stages (소고기의 유통 단계별 병원성 미생물 오염도에 관한 연구)

  • 박성도;김용환;고바라다;김철희;윤병철;김조균
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.2
    • /
    • pp.117-126
    • /
    • 2002
  • Contamination levels of pathogenic microorganisms in 145 cases of beef, which were distributed in Gwangju province, had been investigated in each distributed stage and also monitored by general bacterial count and E coli count index. General bacterial count of beef from the slaughterhouse was 10$^4$cfu/g less than the level of promotion(10 cfu/$\textrm{cm}^2$) and E coli count index was also under the level of 10$^2$cfu/$\textrm{cm}^2$ recommended level of the ministry of agriculture and forestry. Pathogenic microorganisms were detected from 23.2% of samples in the consumption stage, 12.5% in the slaughtering stage and 5.6% in the transporting and processing stage. Staphylococcus aureus was isolated in the largest number and its ratio was 9.0%, listeria monocytogenes 5.5% and salmonella spp 1.4%. There were no samples that bacteria had been detected dually. E coli O157:H7 and campylobacter jejuni were not isolated. In raw and chilled beef, isolation rate of pathogenic microorganisms were 13.3% and 16.5% each. Especially in raw beef, L monocytogenes was. isolated in 3 samples among 30 cases (10%) and S aureus in one sample (3.3%). According to a scale of meat store, isolation rates of pathogenic microorganisms were different. It was 28.6% in the small-scale meat store and 16.7% in the large-scale meat store each. Four cases (16.7%) of S aureus were isolated in the large-scale meat store and seven cases (20.0%) of L monocytogenes and 2 cases (5.7%) of salmonella spp were isolated in the small-scale meat store. S aureus was isolated in two places among 10 feeding facilities of the elementary school. This result shows that the sanitation of elementary school feeding facilities is so poor and more careful policy consideration is needed. Eleven strains of S aureus isolated showed ${\beta}$-hemolysis on blood agar, 1 strain ${\alpha}$-hemolysis, and 1 strain ${\gamma}$-hemolysis. Isolated strains of L monocytogenes were reconfirmed in 560 bp by PCR. Conclusively, these results show that the sanitary condition in the stages of slaughtering, transportation-processing and consumption influences the degree of pathogenic microorganisms contamination in beef severely It is necessary to apply thoroughly hazard analysis critical control point in a process of beef distribution and also to develop rapid test methods for microorganism diagnosis. This effort is very important for the supply of safe and clean meat from farm to table and helpful for the improvement of public health.

Effect of Mn and Fe Compound on the Absorption in the Body and Genital Organs, Activity with F344 Rats (F344 rats를 이용 망간 및 철 화합물의 체내 흡수와 생식기 및 운동성에 미치는 영향)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Choi, Sung-Bong;Kang, Min-Gu;Lee, Chae-Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.224-234
    • /
    • 2007
  • This study aimed to examine the harmful effects of Mn and Fe, which may be generated as dust or fume in the industrial sites, on the body and genital organs by their inhalation. It is intended to find the characteristics and differences of the hazardousness by inhaling a single and the mixed materials of Mn and Fe. Male F344 rats were divided into the control group and 3 exposed groups on the basis of the test material compound (Mn $1.5mg/m^3$, Mn 1.5 and Fe $3.0mg/m^3$, Fe $3.0mg/m^3$). The 4 groups were divided into 4 subgroups again on the basis of the exposure period (4 and 13 weeks) and the recovery period (4 and 13 weeks). The exposure condition was 6 hours a day, 5 days a week for the whole body. Clinical tests including changes in weight and feed rate, blood biochemical test, motility change, changes in the number and the amount of spermatozoon (sperm count), daily sperm production (DSP), deformity test of spermatozoon and changes in the accumulation of Mn and Fe in blood and internal organs were performed. Motility was reduced by Mn exposure. Especially, the effect of Mn was exposure period responsible. By mixing with Fe, no significant change in motility Mn and Fe accumulation in organs was observed. Sperm count and daily sperm production (DSP) were decreased by Mn. Additional effect like the reduction of sperm count and DSP, and delayed restoration of sperm count and DSP during the recovery period were observed in the mixed exposure group. These results indicate that Mn and Fe may affect the motility reduced and has male reproductive toxicity. Mixed exposure of Mn and Fe lead to synergic effects on the male reproductive toxicity.