• 제목/요약/키워드: Cost of $CO_2$ avoided

검색결과 7건 처리시간 0.019초

KEPCO-China Huaneng Post-combustion CO2 Capture Pilot Test and Cost Evaluation

  • Lee, Ji Hyun;Kwak, NoSang;Niu, Hongwei;Wang, Jinyi;Wang, Shiqing;Shang, Hang;Gao, Shiwang
    • Korean Chemical Engineering Research
    • /
    • 제58권1호
    • /
    • pp.150-162
    • /
    • 2020
  • The proprietary post-combustion CO2 solvent (KoSol) developed by the Korea Electric Power Research Institute (KEPRI) was applied at the Shanghai Shidongkou CO2 Capture Pilot Plant (China Huaneng CERI, capacity: 120,000 ton CO2/yr) of the China Huaneng Group (CHNG) for performance evaluation. The key results of the pilot test and data on the South Korean/Chinese electric power market were used to calculate the predicted cost of CO2 avoided upon deployment of CO2 capture technology in commercial-scale coal-fired power plants. Sensitivity analysis was performed for the key factors. It is estimated that, in the case of South Korea, the calculated cost of CO2 avoided for an 960 MW ultra-supercritical (USC) coal-fired power plant is approximately 35~44 USD/tCO2 (excluding CO2 transportation and storage costs). Conversely, applying the same technology to a 1,000 MW USC coal-fired power plant in Shanghai, China, results in a slightly lower cost (32~42 USD/tCO2). This study confirms the importance of international cooperation that takes into consideration the geographical locations and the performance of CO2 capture technology for the involved countries in the process of advancing the economic efficiency of large-scale CCS technology aimed to reduce greenhouse gases

연소 후 $CO_{2}$ 포집공정이 적용된 500MWe 석탄화력발전소의 성능 및 경제성평가 (Performance and Economic Analysis of 500 MWe Coal-Fired Power Plant with Post-Combustion $CO_{2}$ Capture Process)

  • 이지현;김준한;이인영;장경룡;심재구
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.244-249
    • /
    • 2011
  • 연소 후 $CO_{2}$ 포집기술이 적용된 500 MWe 석탄화력발전소의 경제성평가를 수행하고 $CO_{2}$ 저감비용(Cost of $CO_{2}$ avoided)을 산출하였다. 본 연구에서 고려된 $CO_{2}$ 포집기술은 이미 상업적으로 적용이 가능하고, 기존의 화력발전에 적용이 용이한 화학 흡수법을 기초로 하였으며 투자비용 산출을 위해 IEA Greenhouse Gas R&D Programme에서 제시하는 데이터를 활용하였다. 또한 $CO_{2}$ 포집공정 중 가장 많은 발전효율 저하를 가져오는 재열기(리보일러)에 투입되는 열에너지(재생에너지)를 대상으로 민감도분석을 수행하고 각각의 경우에서의 $CO_{2}$ 저감비용을 산출하였다. 분석결과 $CO_{2}$ 포집공정에 적용될 흡수제로 MEA(모노에탄올아민)가 사용되고 재생탑에서 필요한 재생에너지가 3.31 GJ/ton$CO_{2}$ 인 경우 발전효율은 $CO_{2}$ 포집설비 설치 전의 41.0에서 31.6%로 9.4% 감소하고 이때의 $CO_{2}$ 저감비용은 43.3 $/ton$CO_{2}$ 로 산출되었다. 그러나, 흡수제 재생에너지를 변수로 한 민감도분석에서 재생에너지가 2.0 GJ/ton$CO_{2}$로 낮아질 경우 $CO_{2}$ 저감비용은 36.7 $/ton$CO_{2}$까지 낮아질 것으로 분석되었다.

국내 초임계 석탄화력발전소에 연소 후 CO2 포집공정 설치 시 성능 및 경제성 평가 (Performance and Economic Analysis of Domestic Supercritical Coal-Fired Power Plant with Post-Combustion CO2 Capture Process)

  • 이지현;곽노상;이인영;장경룡;심재구
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.365-370
    • /
    • 2012
  • 국내 초임계 석탄화력발전소에 연소 후 $CO_2$ 포집공정을 설치하였을 경우에 예상되는 발전단가와 $CO_2$ 저감비용(Cost of $CO_2$ avoided)을 산출하였다. 본 연구에서 고려된 연소 후 $CO_2$ 포집기술은 이미 상업적으로 적용이 가능하고, 기존의 화력발전에 적용이 용이한 아민 화합물을 이용한 화학 흡수법을 기초로 하였으며, 경제성 평가를 위해 연간 발생하는 비용 및 발전량을 연간 균등화(Levelized)하여 발전단가를 산정하는 수명기간 중 발전단가 분석(LCCA: Life Cycle Cost Analysis) 방식을 활용하여 분석하였다. 경제성 평가에서 가장 중요한 항목 중 하나인 설비 투자비(건설비 등) 및 운영비 산출을 위해, 기존의 $CO_2$ 포집 설비가 없는 기준 석탄화력발전소의 건설비는 IEA(국제에너지기구)에서 제시하는 국내 초임계석탄화력 발전소(순출력 767 MW급)의 데이터를 활용하였으며, 석탄화력발전소에 $CO_2$ 포집설비가 추가된 경우에도 IEA에서 제시하는 기준 석탄화력발전소와 $CO_2$ 포집설비 설치 후의 OECD 평균 순공사비(Overnight cost) 증감분을 참조하여 계산하였다. 상기 데이터를 이용하여 기존 석탄화력발전소 및 $CO_2$ 포집 설비 설치 후의 발전단가 및 $CO_2$ 포집비용을 분석한 결과 $CO_2$ 포집설비 설치 후 발전 효율은 기존 초임계 석탄화력발전소의 발전효율 41%에서 31.6%로 약 9.4%가 저하되었으며, 발전단가는 기존의 45.5 USD/MWh에서 73.9 USD/MWh로 약 62%가 증가되었고 $CO_2$ 포집비용은 41.3 USD/$tCO_2$로 산출되었다.

신재생에너지 경제성 평가 결과 분석 및 평가지표 연구 (Indicators of Economic Evaluation and Case Studies on New & Renewable Energy)

  • 안은영;김성용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.600-603
    • /
    • 2005
  • U.S. National Research Council proposed benefits framework for energy R&D project as economic benefits, environmental benefits, security benefits and knowledge benefits. Following this framework, U.S. National Renewable Energy Laboratory evaluated the projected benefits of Federal Energy Efficiency and Renewable Energy Programs in the indicators of energy-expenditure savings, energy system cost savings, $CO_2$ emissions reductions. oil savings, natural gas saving and avoided additions to central conventional power. As this result, geothermal energy have predominant position in the energy-expenditure savings, natural gas saving and avoided addi t ions to central conventional power to FY2050. The projected benefits, in monetary value, of the whole supply-potential of geothermal energy in Korea were evaluated as 480.2 billion Won, 43.1 billion Won and 135.8 billion Won for the private energy-cost savings, social environmental-cost savings, and import energy-cost saving, respectively.

  • PDF

CCS (Carbon Capture & Sequestration) 기술·경제성 평가 분석 (Development of Techno-Economic Evaluation Model for CCS (Carbon Capture & Sequestration))

  • 이지현;곽노상;이동욱;심재구;이정현
    • 한국기후변화학회지
    • /
    • 제7권2호
    • /
    • pp.111-120
    • /
    • 2016
  • In this study, Techno-economic evaluation model for carbon capture & sequestration (CCS) technologies are reviewed. Based on a key parameters of Korea's electricity market, performance data of 10 MW-scale post-combustion $CO_2$ capture pilot plant in Boryong station, the cost of $CO_2$ avoided was evaluated followed by international guideline suggested by IEA CCS costing methods task force. The result showed that Korea's Electricity cost including CAPEX & OPEX of reference power plant is relatively low compared to OECD nations which lead to a lower CCS cost ($33USD\;t/CO_2$). And future work using newly evaluated CAPEX & OPEX data of power plant with/without CCS is recommended.

도시식생의 주택에너지절약 및 탄소배출저감 기능 -춘천시를 대상으로- (Function of Home Energy Savings and Carbon Emission Reduction by Urban Vegetation- Case of Chuncheon-)

  • 조현길;서옥하;한갑수
    • 한국조경학회지
    • /
    • 제26권3호
    • /
    • pp.104-117
    • /
    • 1998
  • Rising concern about climate change has evoked interest in the potential for urban vegetation to help reduce the level of atmospheric CO\sub 2\, a major heat-trapping gas. This study quantified the functio of home energy savings and carbon emission reduction by shading, evapotranspiration and windspeed reduction of urban vegetatioin in Chuncheon. Tree and shrub cover averaged approximately 13% in residential land. The effects of shading, evapotranspiration and windspeed reduction annually saved heating energy by 2.2% and cooling energy by 8.8%. The heating and cooling energy savings reduced carbon emissions by 3.0% annually. These avoided emissions equaled the amount of carbon emitted annually from fossil fuel consumption by a population of about 1,230. Carbon emission reduction per residential building was 55kg for detached buildings and 872 kg for multifamily buildings. Urban vegetation annually decreased heating and cooling energy cost by ₩1.1 billions, which were equivalent to annual savings of ₩10,000 savings and carbon emission reduction due to tree plantings in the wrong locations, while windspeed reduction had a great effect. Plantings fo large trees close to the west and east wall of buildings, full tree plantings on the north, and avoidance of shade-tree plantings or selection of solar-friendlytrees on the south were recommended to improve the function of building energy savings and carbon emission reduction by urban vegetation.

  • PDF

고효율 습식 아민 CO2 흡수제(KoSol-4)를 적용한 Test bed 성능시험 (Test Bed Studies with Highly Efficient Amine CO2 Solvent (KoSol-4))

  • 이지현;곽노상;이인영;장경룡;장세규;이경자;한광수;오동훈;심재구
    • Korean Chemical Engineering Research
    • /
    • 제51권2호
    • /
    • pp.267-271
    • /
    • 2013
  • KEPCO 전력연구원에서 개발한 고효율 습식 아민 $CO_2$ 흡수제(KoSol-4)를 적용하여 Test bed 성능시험을 수행하였다. 국내에서는 처음으로 석탄화력발전소에서 발생되는 연소 배가스를 적용하여 하루 2톤의 $CO_2$를 처리할 수 있는 연소 후 $CO_2$ 포집기술의 성능을 확인하였으며 또한 국내에서는 유일하게 공정운전에 소요되는 재생에너지 소비량을 실험적으로 측정함으로써 KoSol-4 흡수제의 성능에 대한 신뢰성 있는 데이터를 제시하였다. 흡수제 순환량 및 재생탑 운전압력을 대상으로 한 변수 실험 결과 Test bed 연속운전은 안정적으로 수행되었고, 흡수탑에서의 $CO_2$ 제거율은 국제에너지기구 온실가스 프로그램(IEA-GHG)에서 제시하는 $CO_2$ 포집기술 성능평가 기준치($CO_2$ 제거율: 90%)를 안정적으로 유지하였다. 또한 흡수제(KoSol-4)의 재생을 위한 스팀 사용량(재생에너지)은 3.0~3.2 GJ/$tCO_2$이 소비되는 것으로 산출되었는데 이는 기존 상용 흡수제(MEA, Monoethanolamine)의 재생에너지 수준(약 4.09 GJ/$tCO_2$, 본 연구) 대비 약 25% 이상 저감된 수치일 뿐만 아니라 우리나라에서 연구 중인 모든 $CO_2$ 포집기술을 통틀어 가장 우수한 성능이다. 본 연구를 통해 KEPCO 전력연구원에서 개발한 KoSol-4 흡수제 및 공정의 우수한 $CO_2$ 포집 성능을 확인할 수 있었을 뿐만 아니라, 향후 고효율 흡수제(KoSol-4)를 상용 $CO_2$ 포집플랜트에 적용할 경우 $CO_2$ 포집비용을 크게 낮출 수 있을 것으로 기대되었다.