• Title/Summary/Keyword: Cost Variation Range

Search Result 68, Processing Time 0.03 seconds

Optimization of a capacitive sensor for high dynamic range (높은 동적영역을 갖기 위한 정전용량형 센서의 최적화)

  • Kang, Dae-Sil;Kim, Moo-Jin;Moon, Won-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.92-98
    • /
    • 2010
  • The capacitive sensor has a simple structure, compact size and low cost, but a small dynamic range. The small range is caused by use of gap variation. If the sensor takes area variation type with one plate moving horizontally, it can have a large measurable range. While the area variation has relatively low sensitivity, some studies have found methods to improve the sensitivity. Even though the methods are effective, parameters of the results are limited and 2 dimensional. This study provides more practical and 3 dimensional analysis and suggests relations between parameters. Using the results, the optimized design parameters of a high dynamic range capacitive sensor can be found.

Analysis of Cost Variation of Piping Equipment Design of a Steel Manufacturing Plant by Simulation (시뮬레이션을 통한 제철플랜트 배관장치 설계비용의 변동 범위 분석)

  • Bae, Kyung-Suk;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-seon;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.10 no.4
    • /
    • pp.29-34
    • /
    • 2014
  • In this consideration, this research investigated the piping design items and drew out key design items through interview with experts and surveys to apply them to actual project examples and look into piping design item-specific significance and cost variation ranges. Based on this investigation, the Monte-Carlo simulation was employed herein to analyze the cost variation range for the entire piping design costs with a view to presenting a way to calculate a reasonable bidding price for any similar project and verify the appropriateness of joining a bid.

  • PDF

A Study on the Methodology of Determining Proper SOC Operation Range Considering the Economic Characteristics and the Charge and Discharge Voltage Characteristics of BESS (BESS의 경제성과 충방전 전압 특성을 고려한 적정 SOC 운영 영역 설정 기법에 관한 연구)

  • Yoon, Dae-Sik;Choo, Dae-Hyeok;Ki, Byung-Kook;Kim, Joohn-Sheok;Lee, Byung Ha;Chae, Woo-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.529-536
    • /
    • 2015
  • With the growing interest of microgrid all over the world, many studies on microgrid operation are being carried out. The battery energy storage system(BESS) is a key equipment for effective operation of the microgrid. In this paper, we analyze the characteristics of the charge and discharge output voltage of the battery and the characteristics of the life-span variation and the investment cost when the state-of-charge (SOC) changes. The formulas to represent the quality of the charge and discharge output voltage of the battery and the economics due to the life-span variation and the investment cost according to DOD(Depth of Discharge) are derived. The methodology of determining the proper operation ranges of the battery SOC with varying the weighting of the quality of its charge and discharge output voltage of the battery and the economics due to its life-span variation and the investment cost is presented using these formulas.

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

Variation of Hospital Costs and Product Heterogeneity

  • Shin, Young-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.11 no.1
    • /
    • pp.123-127
    • /
    • 1978
  • The major objective of this research is to identify those hospital characteristics that best explain cost variation among hospitals and to formulate linear models that can predict hospital costs. Specific emphasis is placed on hospital output, that is, the identification of diagnosis related patient groups (DRGs) which are medically meaningful and demonstrate similar patterns of hospital resource consumption. A casemix index is developed based on the DRGs identified. Considering the common problems encountered in previous hospital cost research, the following study requirements are estab-lished for fulfilling the objectives of this research: 1. Selection of hospitals that exercise similar medical and fiscal practices. 2. Identification of an appropriate data collection mechanism in which demographic and medical characteristics of individual patients as well as accurate and comparable cost information can be derived. 3. Development of a patient classification system in which all the patients treated in hospitals are able to be split into mutually exclusive categories with consistent and stable patterns of resource consumption. 4. Development of a cost finding mechanism through which patient groups' costs can be made comparable across hospitals. A data set of Medicare patients prepared by the Social Security Administration was selected for the study analysis. The data set contained 27,229 record abstracts of Medicare patients discharged from all but one short-term general hospital in Connecticut during the period from January 1, 1971, to December 31, 1972. Each record abstract contained demographic and diagnostic information, as well as charges for specific medical services received. The 'AUT-OGRP System' was used to generate 198 DRGs in which the entire range of Medicare patients were split into mutually exclusive categories, each of which shows a consistent and stable pattern of resource consumption. The 'Departmental Method' was used to generate cost information for the groups of Medicare patients that would be comparable across hospitals. To fulfill the study objectives, an extensive analysis was conducted in the following areas: 1. Analysis of DRGs: in which the level of resource use of each DRG was determined, the length of stay or death rate of each DRG in relation to resource use was characterized, and underlying patterns of the relationships among DRG costs were explained. 2. Exploration of resource use profiles of hospitals; in which the magnitude of differences in the resource uses or death rates incurred in the treatment of Medicare patients among the study hospitals was explored. 3. Casemix analysis; in which four types of casemix-related indices were generated, and the significance of these indices in the explanation of hospital costs was examined. 4. Formulation of linear models to predict hospital costs of Medicare patients; in which nine independent variables (i. e., casemix index, hospital size, complexity of service, teaching activity, location, casemix-adjusted death. rate index, occupancy rate, and casemix-adjusted length of stay index) were used for determining factors in hospital costs. Results from the study analysis indicated that: 1. The system of 198 DRGs for Medicare patient classification was demonstrated not only as a strong tool for determining the pattern of hospital resource utilization of Medicare patients, but also for categorizing patients by their severity of illness. 2. The wei틴fed mean total case cost (TOTC) of the study hospitals for Medicare patients during the study years was $11,27.02 with a standard deviation of $117.20. The hospital with the highest average TOTC ($1538.15) was 2.08 times more expensive than the hospital with the lowest average TOTC ($743.45). The weighted mean per diem total cost (DTOC) of the study hospitals for Medicare patients during the sutdy years was $107.98 with a standard deviation of $15.18. The hospital with the highest average DTOC ($147.23) was 1.87 times more expensive than the hospital with the lowest average DTOC ($78.49). 3. The linear models for each of the six types of hospital costs were formulated using the casemix index and the eight other hospital variables as the determinants. These models explained variance to the extent of 68.7 percent of total case cost (TOTC), 63.5 percent of room and board cost (RMC), 66.2 percent of total ancillary service cost (TANC), 66.3 percent of per diem total cost (DTOC), 56.9 percent of per diem room and board cost (DRMC), and 65.5 percent of per diem ancillary service cost (DTANC). The casemix index alone explained approximately one half of interhospital cost variation: 59.1 percent for TOTC and 44.3 percent for DTOC. Thsee results demonstrate that the casemix index is the most importand determinant of interhospital cost variation Future research and policy implications in regard to the results of this study is envisioned in the following three areas: 1. Utilization of casemix related indices in the Medicare data systems. 2. Refinement of data for hospital cost evaluation. 3. Development of a system for reimbursement and cost control in hospitals.

  • PDF

The Study on the design of durability of Concrete in Agricultural Hydraulic Structures (농업용 수리구조물의 내구성 설계방안 연구)

  • Park Kwang Su;Kim Meyong Won;Kim Kwan Ho;Lee Joon Gu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.830-833
    • /
    • 2004
  • Hydraulic structures have been constructed with low cost concrete so as to increase the investment efficiency. But, it has caused to produce structures having excess internal voids inside concrete. As the construction of agricultural irrigation and drainage project is concentrated on off-farming season and scattered in wider area, variation of quality of structures is big and it caused increase of internal voids. Due to that reason, hazardous substance is passing rather freely through the voids causing occur of crack and accordingly life time of structures is getting shortened. It is necessary to make a thesis of design criteria for design strength to increase life time, range of variation of quality, strength of ready-mixed concrete proper to design strength, and water-cement ratio and air content.

  • PDF

Experimental Study on Adjustment of Inlet Nozzle Section to Flow Rate Variation for Darrieus-type Hydro-Turbine

  • Watanabe, Satoshi;Shimokawa, Kai;Furukawa, Akinori;Okuma, Kusuo;Matsushita, Daisuke
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • A two dimensional Darrieus-type turbine has been proposed for the hydropower utilization of extra-low head less than 2m. In a practical use of Darrieus-type hydro-turbine, head and flow rate may be varied temporally and seasonally. Considering that the cost advantage is required for the low head hydro turbine system, the Darrieus turbine should be operated with high efficiency in the wider range of flow rate possibly by using an additional device with simpler mechanism. In the present paper, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed to obtain the preferable inlet velocity in low flow rate conditions. Effects of resulting spanwise partial inlet flow are investigated. Finally, an effective modification of inlet nozzle height over flow rate variation is shown.

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.

Influence of Propellant Mixture ]Ratio Variation near Chamber Wall (액체로켓엔진의 내부 벽면 근처에서의 추진제 혼합비 변화의 영향에 대한 연구)

  • Han Poong-Gyoo;Chang Haeng-Soo;Cho Yong-Ho;Kim Kyoungho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.255-258
    • /
    • 2002
  • Liquid rocket engines using liquefied natural gas (LNG) or methane as a fuel is known to have several good characteristics, such as high specific impulse compared to other hydrocarbon fuels, environment-friendly exhaust gas, low production cost, and re-usability with low soot generation in the cooling channel. In this study, experimental combustion chambers capable of using LNC and $CH_{4}$ are being researched through experimental firing tests, and within easy range of eyes' inspection, there are the periodical existence of soot or discoloration in the chamber wall surface. This result means that mixture ratio of oxidizer and fuel fluctuates periodically between outer-row injectors in the mixing head in the circumferential direction. Therefore, based on this phenomenon, the variation of mixture ratio near the chamber wall caused by the spill pattern of a shear coaxial injector was analyzed quantitatively and the thermal heat flux Into the cooling channel is modified. Then, the calculated and modified results are compared with the measured ones.

  • PDF

In-situ Performance Evaluation of a Ground Source Heat Pump for an Air Conditioning System (공조시스템용 지열히트펌프의 실증평가에 관한 연구)

  • Park, Youn-Cheol;Park, Seong-Koo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • In this study, the ground source heat pump was installed at a research center in Jeju Island to verify the performance of the system and to give an information for a economic feasibility. The performance test was conducted until the heat storage tank temperature reached at $5^{\circ}C$ from $50^{\circ}C$ in the cooling operation, and until the storage temperature goes up to $50^{\circ}C$ from $10^{\circ}C$ in the heating mode. As results, the system performance shows that $2.2{\sim}3.5$ for the cooling operation and $2.5{\sim}3.5$ for heating operation. It is found that the underground is good heat source for the heat pump with $3{\sim}10^{\circ}C$ variation range. The ground source heat pump could be connected one of air conditioning system without any problem in system performance. Based on the economic analysis, the initial cost for the ground source heat pump will be compensated after 4 years operation. If the system runs 20 years, approximately 300 million Won will be saved when the air conditioning system adapt the ground source heat pump based on Life Cycle Cost analysis.