• 제목/요약/키워드: Cosmetic purpose

검색결과 587건 처리시간 0.024초

Pollen-Food Allergy Syndrome in Korean Pollinosis Patients: A Nationwide Survey

  • Kim, Mi-Ae;Kim, Dong-Kyu;Yang, Hyeon-Jong;Yoo, Young;Ahn, Youngmin;Park, Hae-Sim;Lee, Hyun Jong;Jeong, Yi Yeong;Kim, Bong-Seong;Bae, Woo Yong;Jang, An-Soo;Park, Yang;Koh, Young-Il;Lee, Jaechun;Lim, Dae Hyun;Kim, Jeong Hee;Lee, Sang Min;Kim, Yong Min;Jun, Young Joon;Kim, Hyo Yeol;Kim, Yunsun;Choi, Jeong-Hee;Work Group for Rhinitis, the Korean Academy of Asthma, Allergy and Clinical Immunology
    • Allergy, Asthma & Immunology Research
    • /
    • 제10권6호
    • /
    • pp.648-661
    • /
    • 2018
  • Purpose: Pollen-food allergy syndrome (PFAS) is an immunoglobulin E (IgE)-mediated allergy in pollinosis patients caused by raw fruits and vegetables and is the most common food allergy in adults. However, there has been no nationwide study on PFAS in Korea. In this study, we investigated the prevalence and clinical characteristics of PFAS in Korea. Methods: Twenty-two investigators participated in this study, in which patients with allergic rhinoconjunctivitis and/or bronchial asthma with pollen allergy were enrolled. The questionnaires included demographic characteristics, a list of fruits and vegetables, and clinical manifestations of food allergy. Pollen allergy was diagnosed by skin prick test and/or measurement of the serum level of specific IgE. Results: A total of 648 pollinosis patients were enrolled. The prevalence of PFAS was 41.7% (n = 270). PFAS patients exhibited cutaneous (43.0%), respiratory (20.0%), cardiovascular (3.7%) or neurologic symptoms (4.8%) in addition to oropharyngeal symptoms. Anaphylaxis was noted in 8.9% of the PFAS patients. Seventy types of foods were linked to PFAS; e.g., peach (48.5%), apple (46.7%), kiwi (30.4%), peanut (17.4%), plum (16.3%), chestnut (14.8%), pineapple (13.7%), walnut (14.1%), Korean melon (12.6%), tomato (11.9%), melon (11.5%) and apricot (10.7%). Korean foods such as taro/taro stem (8.9%), ginseong (8.2%), perilla leaf (4.4%), bellflower root (4.4%), crown daisy (3.0%), deodeok (3.3%), kudzu root (3.0%) and lotus root (2.6%) were also linked to PFAS. Conclusions: This was the first nationwide study of PFAS in Korea. The prevalence of PFAS was 41.7%, and 8.9% of the PFAS patients had anaphylaxis. These results will provide clinically useful information to physicians.

Reverse Superficial Sural Artery Flap for the Reconstruction of Soft Tissue Defect Accompanied by Fracture of the Lower Extremity (하지 골절과 동반된 연부조직 결손 재건을 위한 역행성 비복동맥 피판술)

  • Han, Soo-Hong;Hong, In-Tae;Choi, SeongJu;Kim, Minwook
    • Journal of the Korean Orthopaedic Association
    • /
    • 제55권3호
    • /
    • pp.253-260
    • /
    • 2020
  • Purpose: Soft tissue defects of the distal lower extremity are commonly accompanied by a fracture of the lower extremities. Theses defects are caused by the injury itself or by complications associated with surgical treatment of the fracture, which poses challenging problem. The reverse superficial sural artery flap (RSSAF) is a popular option for these difficult wounds. This paper reviews these cases and reports the clinical results. Materials and Methods: Between August 2003 and April 2018, patients who were treated with RSSAF for soft tissue defects of the lower third of the leg and ankle related to a fracture were reviewed. A total of 16 patients were involved and the mean follow-up period was 18 months. Eight cases (50.0%) of the defects were due to an open fracture, whereas the other eight cases (50.0%) were postoperative complication after closed fracture. The largest flap measured 10×15 cm2 and the mean size of the donor sites was 51.9 cm2. The flap survival and postoperative complications were evaluated. Results: All flaps survived without complete necrosis or failure. One case with partial necrosis of the flap was encountered, but the wound healed after debridement and repair. One case had a hematoma with a pseudoaneurysmal rupture of the distal tibial artery. On the other hand, the flap was intact and the wound healed after arterial ligation and flap advancement. A debulking operation was performed on three cases for cosmetic reasons and implant removal through the flap was performed in three cases. No flap necrosis was encountered after these additional operations. Conclusion: RSSAF is a relatively simple and safe procedure for reconstructing soft tissue defects following a fracture of the lower extremity that does not require microsurgical anastomosis. This can be a useful treatment option for soft tissue defects on the distal leg, ankle, and foot.

Wedge-Shaped Resection for Massive Xanthomatosis of Achilles Tendon (양측 아킬레스건에 발생한 거대 황색종의 쐐기형 절제술을 이용한 수술적 치료)

  • Kim, Sungmin;Ahn, Yeong Seub;Jung, Dong-Min;Jung, Sung Taek
    • Journal of the Korean Orthopaedic Association
    • /
    • 제56권2호
    • /
    • pp.157-163
    • /
    • 2021
  • Purpose: Xanthomatosis of the Achilles tendons is rare. In some patients, however, the lesions in the Achilles tendon need to be removed, which may be painful and disfiguring. While studies of successful surgical outcomes for the total resection and reconstruction of the Achilles tendon have been reported, reconstruction surgery has a technical challenge, and extended surgical exposures are required. This study analyzed five cases of bilateral xanthoma of the Achilles tendon, which was treated surgically using a wedge-shaped tendon-sparing approach to eliminate the need for tendon reconstruction. Materials and Methods: From July 2010 to May 2018, five patients with xanthomatosis in both Achilles tendons underwent wedge-shaped tendon preserving surgery. The average age was 49 years (range, 40-55 years), and the follow-up period was 21.4 months (range, 12-31 months). The patients consisted of three males and two females. Complications related to surgery were recorded. The outcome measures included the range of motion of the ankle joint, American Orthopaedic Foot and ankle Society (AOFAS) ankle/hindfoot score, and visual analogue scale (VAS) for overall satisfaction at the last follow-up. The availability of a single-limb heel raise and returning time to work were also measured. Results: Wound dehiscence that did not require secondary surgery was noted in one patient. At the last follow-up, the range of motion of the ankle joint was normal in all patients. The mean AOFAS ankle/hindfoot score was 91 (range, 85-96) and the VAS for the overall satisfaction ranged from 8 to 10. The average time between surgery and return to work was 27.6 days (range, 17-58 days) and all patients could perform a single-limb heel raise test. Conclusion: The tendon-sparing technique, which can preserve the anatomical functioning of the Achilles tendon, could be an excellent surgical approach because it has very promising functional and cosmetic surgical outcomes in patients with Achilles tendon xanthomatosis.

Verification of Anti-Inflammatory Efficacy of Apple Mango (Mangifera indica L.) Peel in LPS-Activated Macrophage (LPS에 의해 활성화된 대식세포에서 애플망고 껍질(Mangifera indica L. Peel)의 항염증 효능 검증)

  • Hyo-Min Kim;Dan-Hee Yoo;In-Chul Lee
    • Microbiology and Biotechnology Letters
    • /
    • 제50권3호
    • /
    • pp.337-346
    • /
    • 2022
  • The purpose of this study was to investigate the antioxidant and anti-inflammatory activities of hot water (AMPW) and 70% ethanol (AMPE) extracts of apple mango (Mangifera indica L.) peel. The antioxidant activities were measured using a total polyphenol, electron-donating, 2,2'-azinobis [3-ethylbenzothiazoline6-sulfonic acid] (ABTS) radical scavenging assay. The total polyphenol content of AMPW and AMPE was 66.08 ± 0.62 mg TAE/100 g and 100.13 ± 0.23 mg TAE/100 g, respectively. As a result of measuring the electrondonating ability, at a concentration of 1,000 ㎍/ml, AMPW and AMPE showed an effectiveness of 86% and 94%, respectively. The ABTS assay showed 80% and 98% respective radical scavenging activity for AMPW and AMPE, at a concentration of 1,000 ㎍/ml. The cell viability on macrophage cells was performed using a 3-[4,5-dimethyl-thiazol-2-yl]-2,5-diphenyl-tetrazoliumbromide (MTT) assay, and the results showed more than 90% cell viability at a 100 ㎍/ml concentration. Anti-inflammatory activity was verified by confirming nitric oxide (NO) production inhibitory activity, inducible nitric oxide synthase (iNOS), and cyclooxygenase-2 (COX-2) protein and mRNA expression inhibitory activity from lipopolysaccharide (LPS)-treated RAW 264.7 cells. The NO production inhibitory effects were measured using the Griess assay, which confirmed 45% and 40% inhibition after treatment with AMPW and AMPE, respectively. Moreover, the protein and mRNA expression of inflammatory-related factors iNOS and COX-2, decreased in a concentrationdependent manner. In conclusion, this study showed antioxidant and anti-inflammatory effects of Mangifera indica L. peel and revealed its promising potential for application as an antioxidant and anti-inflammatory agent.

A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture (쇄골 간부 골절의 최소 침습적 경피적 금속판 고정술과 관혈적 수술 비교)

  • Yoo, Seong-Ho;Kang, Suk-Woong;Kim, Bu-Hwan;Song, Moo-Ho;Kim, Yeong-Joon;Park, Gyu-Taek;Kwack, Chang-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • 제52권1호
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. Materials and Methods: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year-among all cases of MIPPO and open plate fixation-were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. Results: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. Conclusion: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.

Clinical Results of Anterolateral Thigh Perforator Flap for Soft Tissue Reconstruction of the Foot and Ankle (족부 및 족관절부 연부조직 재건을 위한 전외측 대퇴 천공지 피판술의 임상결과)

  • Han, Soo-Hong;Hong, In Tae;Lee, Yohan;Jo, Yong-Gil;Kwon, Young Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • 제52권1호
    • /
    • pp.40-48
    • /
    • 2017
  • Purpose: Soft tissue reconstruction of a defect around the foot and ankle is a particularly challenging procedure due to the anatomical and functional characteristics of this area. Hence, only a limited number of treatment options are available. Moreover, if patients wish to avoid additional scars on the ipsilateral lower leg for cosmetic reasons, even fewer options are available for treatment. The authors used an anterolateral thigh perforator flap for soft tissue defects in this area, when other surgical options were inadequate. The aim of this study was to report the clinical results and the efficacy of this procedure. Materials and Methods: Sixteen cases of soft tissue defects around the foot and ankle were included. Participants included 12 male and 4 female subjects, and the mean age was 34 years. The most common cause of defect was acute trauma, and the average follow-up period was 33 months. Flap survival time, surgical complications, and ambulation status at the final follow-up stage were evaluated. Results: All 16 flaps successfully survived, except for one case with partial flap necrosis that was thought to be due to weight bearing earlier than scheduled. All patients were able to walk independently without any aid at the final follow-up stage. No patients showed other significant surgical complications. Conclusion: The anterolateral thigh perforator flap is a good alternative for soft tissue defects of the foot and ankle, when other options are not applicable. This study also demonstrated that surgery using an anterolateral thigh perforator flap is safe and highly reliable.

A Study on the Countermeasures Taken By the Korean Healthcare and Life Sciences Industry Regarding U.S. Import Refusals: Focus on the Analysis of FDA Violation Codes (한국 바이오헬스 산업의 미국 수입거부 대응 방안 연구 : FDA 위반코드 분석을 중심으로)

  • Yu-Han Lee;Hag-Min Kim
    • Korea Trade Review
    • /
    • 제48권3호
    • /
    • pp.131-150
    • /
    • 2023
  • The purpose of this study was to find a countermeasure to the U.S. import refusals for the Korean healthcare and life sciences industry. To this end, an analysis of trends during the pandemic was conducted using the KITA Border Rejection Database, which includes information on items and types of import refusals. The reason for rejection was also analyzed according to the FDA violation codes. The degree of countermeasure for import refusals was identified by measuring the unit rejection rate (URR). The results of the analysis showed that the major U.S. import refusals for the Korean healthcare and life sciences industry had expanded from contact lenses to COVID-19 diagnostic kits and drugs after the pandemic broke out. The major reasons for import refusals were non-compliance with the Predicate Device and Drugs Act and non-approval by the FDA for products and facilities. On the other hand, the unit rejection rate (URR) of major items in the Korean healthcare and life sciences industry was measured higher than the industry average. The results therefore showed a low level of response to U.S. import refusals. The results of the analysis of reasons for import refusals by item according to FDA violation codes were as follows. First of all, the main violation for contact lenses and COVID-19 diagnostic kits corresponded to misbranding. This was often due to the fact that Korean companies did not provide the relevant notices and information required by the FDA. Many cases also failed to demonstrate a substantial equivalency compared to predicate devices already on the market. On the other hand, applications for new unapproved drugs were not accepted as they had yet to pass relevant regulations that would prove their safety and efficacy. In conclusion, import refusals for the Korean healthcare and life sciences industry were found to be closely related to technical barriers to trade (TBT).