• Title/Summary/Keyword: Cortical Endplate

Search Result 5, Processing Time 0.016 seconds

Influence of Cortical Endplates on Ultrasonic Properties of Trabecular Bone (피질골판이 해면질골의 초음파 특성에 미치는 영향)

  • Kim, Yoon Mi;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 MHz and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

Anterior Cervical Discectomy and Fusion Using a Stand-Alone Polyetheretherketone Cage Packed with Local Autobone : Assessment of Bone Fusion and Subsidence

  • Park, Jeong-Ill;Cho, Dae-Chul;Kim, Kyoung-Tae;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.189-193
    • /
    • 2013
  • Objective : It remains debatable whether cervical spine fusion cages should be filled with any kind of bone or bone substitute. Cortical and subcortical bone from the anterior and posterior osteophytes of the segment could be used to fill the cage. The purposes of the present study are to evaluate the clinical outcomes and radiological outcomes including bone fusion and subsidence that occurred after anterior cervical discectomy and fusion using a stand-alone cage packed with local autobone graft. Methods : Thirty-one patients who underwent anterior cervical fusion using a stand-alone polyetheretherketone (PEEK) cage packed with local autobone graft from July 2009 to december 2011 were enrolled in this study. Bone fusion was assessed by cervical plain radiographs and computed tomographic scan. Nonunion was evaluated according to the absence of bony bridge on computed tomographic scan. Subsidence was defined as a ${\geq}2$ mm decrease of the interbody height at the final follow-up compared to that measured at the immediate postoperative period. Results : Subsidence was observed in 7 patients (22.6%). Of 7 patients with subsidence greater 2 mm, nonunion was developed in 3. Three patients with subsidence greater 2 mm were related with endplate damage during intraoperative endplate preparation. Solid bone fusion was achieved in 28 out of 31 patients (90.3%). Conclusion : With proper patient selection and careful endplate preparation, anterior cervical discectomy and fusion (ACDF) using a stand-alone PEEK cage packed with local autobone graft could be a good alternative to the standard ACDF techniques with plating.

Effect of Bone Cement Volume and Stiffness on Occurrences of Adjacent Vertebral Fractures after Vertebroplasty

  • Kim, Jin-Myung;Shin, Dong Ah;Byun, Dong-Hak;Kim, Hyung-Sun;Kim, Sohee;Kim, Hyoung-Ihl
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.435-440
    • /
    • 2012
  • Objective : The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. Methods : A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L1 vertebrae. Volumes of bone cement, with appropriate mechanical properties, were inserted into the trabecular core of the T12 vertebra. Parametric studies were done by varying the volume and stiffness of the bone cement. Results : When the bone cement filling volume reached 30% of the volume of a vertebral body, the level of stiffness was restored to that of normal bone, and when higher bone cement exceeded 30% of the volume, the result was stiffness in excess of that of normal bone. When the bone cement volume was varied, local stress in the bony structures (cortical shell, trabecular bone and endplate) of each vertebra monotonically increased. Low-modulus bone cement has the effect of reducing strain in the augmented body, but only in cases of relatively high volumes of bone cement (>50%). Furthermore, varying the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies. Conclusion : The volume of cement was considered to be the most important determinant in endplate fracture. Changing the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies.

Load Sharing Ratios Between the Cortex and Centrum in a Lumbar Vertebral Body with aging using Finite Element Method (유한 요소 법을 이용한 노화에 따른 요추의 피질 골과 해면 골 간의 하중 분담 비율)

  • Lim, JongWan
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.90-103
    • /
    • 2016
  • This research was aimed to analyze load sharing ratios between cortical shell and trabecular bone of a degraded lumbar vertebra with aging, and also evaluate elastic moduli assigned into an FE model, using finite element method. For the better analysis of trabecular bone, effective elastic moduli, that is, nominal elastic moduli divided by the volumetric porosities was used. The elastic moduli of the cortical shell suitable for the trabecular bone were obtained from the equations on the basis of idealized stress-strain relations, including areal porosities. To minimize numerical errors, p-element was used. Using eight parameters that refer to some published papers, the geometry of L3 with a removed posterior part. After the constant compressive displacement was applied, the load sharing ratios were obtained by using both every elastic strain energy and every vertical force between two bones in each 8-volume. As results, 1) according to an increase in age from 20-year to 80-year, load sharing ratios of trabecular bone decreased from 55% to 49%; 2) the maximal ratios of each bone were occurred in the mid-plane of centrums and the endplate of cortical shells, respectively; 3) effective elastic moduli assigned into a porous centrum/cortex were found to be adequate; 4) for load sharing ratios, the difference of two methods showed that the total ratios were almost same within less than 1% but the partial ratios at every depth were more or less different each other.

The Value of Preoperative MRI and Bone Scan in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures (골다공증성 척추체 압박골절에 대한 경피적 척추성형술시 자기공명영상과 골 주사 검사의 의의)

  • Kim, Se Hyuk;Lee, Wan Su;Seo, Eui Kyo;Shin, Yong Sam;Zhang, Ho Yeol;Jeon, Pyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.907-915
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty is often complicated by the presence of multiple fractures or non-localizing pain in the patients with osteoporotic vertebral fractures. The purpose of this study is to estimate the value of preoperative radiologic studies in the localization of symptomatic vertebrae and to determine the factors which can influence on the clinical results. Materials and Methods : We retrospectively reviewed the clinical and radiologic data of 57 vertebrae in 30 patients underwent percutaneous vertebroplasty for osteoporotic vertebral compression fractures. Inclusion criteria was severe pain(McGill-Melzack score 3, 4 or 5) associated with the acute vertebral fractures and absence of spinal nerve root or cord compression sign. Acute symptomatic vertebral fracture was determined by the presence of signal change on MR images or increased uptake on whole body bone scan. Results : Pain improvement was obtained immediately in all patients and favorable result was sustained in 26 patients(86.7%) during the mean follow-up duration of 4.7 months(5 complete pain relief, 21 marked pain relief). Those who underwent vertebroplasty for all acute symptomatic vertebrae had significantly better clinical result than those who did not. Further vertebral collapse and eventual bursting fracture occurred in 1 vertebra which showed intradiskal leakage of bone cement and disruption of cortical endplate on postoperative CT scan. Conclusion : Preoperative MR imaging and whole body bone scan are very useful in determining the symptomatic vertebrae, especially in the patients with multiple osteoporotic vertebral fractures. To obtain favorable clinical result, the careful radiologic evaluation as well as clinical assessment is required. Control of PMMA volume seems to be the most critical point for avoiding complications.

  • PDF