• Title/Summary/Keyword: Corrosion prevention system

Search Result 43, Processing Time 0.033 seconds

Evaluation for Corrosion Prevention Properties of Steel Bar Corrosion Repair Method Composed of Primer and Section Restoration Mortar with Corrosion Inhibitor (방청제 혼입 프라이머 및 단면복구모르타르를 사용한 철근부식보수공법의 철근방청성능 평가)

  • Cho Bong Suk;Jang Jae Bong;Jang Jong Ho;Kim Yong Ro;Kang Suk Pyo;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.793-796
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation. chemical decay et. being developed and applied. However, present polymer cement mortar applied to section restoration system cause the problem of long-term working and economica] efficiency. because that is divided into two process of liquid corrosion prevention agent and polymer cement mortar. In this background, accelerated test with due regard to $3\%$ NaCl soaking and autoclave cure was performed to confirm steel bar corrosion prevention properties of polymer cement mortar mixed with corrosion prevention agent of powdered type. In conclusion. we confirmed application possibility and excellency of steel bar corrosion prevention properties of polymer cement mortar mixed with corrosion prevention agent of powdered type comparing general polymer cement mortar applied to section restoration system of present study.

  • PDF

Stabilization of Initial Start-up of Corrosion Prevention Rectifier by DCM Operation of Single-phase Inverter (단상 인버터의 DCM 동작에 의한 부식 방식용 정류기의 초기기동 안정화)

  • Hong-Ju Ju;Seong-Mi Park;Sung-Jun Park;Jun-Jae An
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.5
    • /
    • pp.1189-1197
    • /
    • 2024
  • Due to the rapid development of the industry, the use of iron is increasing rapidly in various industrial fields. Among these iron use areas, problems caused by corrosion of iron are seriously occurring in water-related industries. In particular, as the importance of environmental management has emerged, the water industry market desperately needs to replace aging water infra structure due to corrosion. In order to overcome this problem, research on a method capable of corrosion prevention system is being actively conducted. As the method for corrosion prevention system has various voltages and currents applied depending on the surrounding environment, the demand for an appropriate voltage regulator is increasing rapidly. In particular, as the IOT industry develops, the capacity of corrosion prevention system is increasing by expanding the area in which the method machine operates. Therefore, rectifiers for preventing corrosion are being changed from conventional flyback systems suitable for small capacities to inverter-type rectifiers suitable for large capacities. The inverter-type rectifier has various problems by reducing it to the initial rush current when starting. Therefore, this paper proposes a new starting method that can reduce initial inrush current in inverter-type rectifiers. T he proposed method can secure DC phase voltage for stable operation of the inverter by implementing discontinuous boosting operation using the switch of the inverter. In addition, the excellence of the proposed method was verified through simulations and experiments.

Investigation on electrochemical performance of Al anode material for marine growth prevention system

  • Kim, Seong-Jong;Jang, Seok-Ki;Han, Min-Su;Lee, Seung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.968-973
    • /
    • 2014
  • Aluminum anode of marine growth prevention system for ship is installed in seachest or sea water strainer. The Al anode is connected to a control panel that feeds a current to the anode. The dissolved ions produced by the anode are transferred in sea water, spreads through the sea water pipe system and creates a protective film in the pipelines. Thereby, corrosion in pipeline system significantly is reduced. In application on condition as a steel ship, the big accident can be caused by the corrosion. Accordingly, in this research, we evaluated influence of applied current and flow velocity on electrochemical characteristics of Al anode for marine growth prevention system (MGPS). Based on the results of the erosion-cavitation experiments, cavitation rate increased greatly until 120 min. of the experimental time and decreased a little at the point of 180 min. where pit grew and merging occurred but showed a tendency of steadily increasing consumption rates. Based on the results of the Tafel analysis, compared to static states, corrosion current densities show a rapidly increasing tendency when flow occurred.

A Study on the Effect of Corrosion Prevention in Water Distribution System by Galvanized Zinc-Brass Pipe (아연-황동관에 의한 배관 부식 억제 효과에 관한 연구)

  • Song, Seung-Joon;Cho, Young-Guen;Kim, Jin-Han
    • Journal of Urban Science
    • /
    • v.7 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • This research was carried out to investigate the corrosion prevention effect in the water distribution system by galvanized zinc-brass pipe which is using potential between brass and zinc. As a result of this study, pH and conductivity of influent were constant in spite of its installation, and it was difficult to estimate the effect of the installation with temporary increased and reduced concentration of Zn and Fe ions, respectively. However, since the corrosion rate of the steel coupon with galvanized zinc-brass pipe was relatively low, it has an effect of inhibiting corrosion.

Power Supply System Configuration for Preventing Corrosion on Pipeline using a Low-cost SMPS Chip

  • Sung-Gi Chae;Jun-Jae An;Gwang-Cheol Song;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.5
    • /
    • pp.1099-1109
    • /
    • 2024
  • As a wide range of industries using iron, such as water and sewerage pipes, gas pipelines, heat pipes, electric engines, communication pipes, and oil pipelines, rapidly become active, there is a demand for reliability and low cost of DC power supplies that can prevent corrosion of pipe networks. In particular, high-efficiency corrosion prevention systems due to changes in the perception of carbon emissions and energy saving are essential elements. Therefore, the construction of a switching-type corrosion current controller is being activated. Also, in such systems, DC/DC converters capable of multi-channel current control are demanded for corrosion prevention functions and uniform consumption of sacrificial anodes. This paper proposes a new current supply system for preventing pipeline corrosion using a low-cost SMPS dedicated chip. The proposed method can maintain excellent parallel operation function, protection function, and response speed by configuring a current controller using a hybrid method using analog and digital. The proposed method verified its superiority through simulations and experiments.

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

The Development of Real-Time Wireless Remote Corrosion Monitoring System Using TRS(II) (TRS를 이용한 실시간 무선 원격 부식감시시스템 개발(II))

  • Bae, Jeong-Hyo;Kim, Dae-Kyeong;Ha, Tae-Hyun;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.618-620
    • /
    • 1999
  • The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or collapse of bridge and building and so on. So, he has been spent the money and the time for corrosion monitoring and analysis of measuring data. Therefore, KERI(Korea Electrotechnology Research Institute) has developed the real-time wireless remote corrosion monitoring system using by TRS(Trunked Radio System). The results of development for corrosion monitoring system are described briefly. Especially, the interfacing technology between the server and rectifier introduced in this paper.

  • PDF

Development of Integrated Corrosion Monitoring and Control System (통합 부식 모니터링 및 통합 제어 시스템의 개발)

  • Yoo, Nam-Hyun;Kim, Young-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.8-14
    • /
    • 2013
  • Although there are various factors that threaten the security of ships, one of the most harmful is corrosion. It is not easy to find corroding areas and the status of corrosion, even though corrosion causes serious problems such as submergence and marine pollution as a result of leaking oil and polluted water. To monitor the corrosion of ships, non-destructive inspection, weight loss coupons, electrical resistance, linear polarization resistance, zero resistance ammeter, and electrochemical impedance spectroscopy have been developed. However, these methods require much time to detect corrosion, and most are not appropriate for real time monitoring. Coating, sacrificial anode, and impressed current cathodic protection (ICCP) methods have been developed to control corrosion. The ICCP and sacrificial anode methods are the most popular ways to prevent ship corrosion. However, ICCP is only appropriate for the outside of a ship and cannot be used for complex structures such as ballast tanks because these are composed of many separate chambers. Sacrificial anodes have to be replaced periodically. This paper proposes an integrated corrosion monitoring and control system (ICMCS) that can detect corrosion in real time and is appropriate for complex structures such as ballast tanks. Because the system uses titanium for an anode, exhausted anodes do not need to be replaced.

The Remote Wireless Corrosion Monitoring System for Water Pipeline (상수도 배관용 무선 원격 부식모니터링 시스템)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.637-640
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in oder to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. In this paper, results of development about remote wireless corrosion monitoring system for water pipe line are presented briefly.

  • PDF

Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor (부식 및 스케일 억제제에 의한 냉각수 수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of Environmental Science International
    • /
    • v.18 no.2
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.