• Title/Summary/Keyword: Corrosion measurement

Search Result 432, Processing Time 0.032 seconds

Effect of Two-Step Aging Treatment on the Stress Corossion Cracking Resistance of 7050 Al Alloy (7050 Al합금의 응력부식저항성에 미치는 2단 시효처리의 영향)

  • Choe, Jung-Hwan;Kim, Jong-Gi;Kim, Heon-Gyu;Lee, Sang-Rae;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.695-700
    • /
    • 1999
  • Effects of two-step aging treatment on the stress corrosion cracking(SCC) resistance of 7050 Al alloy were investigated by transmission electron microscopy, electrical conductivity measurement and stress corrosion facter(SCF) evaluation. It was found that η', principal hardening phase, transformed to η during over aging above maximum hardness, and SCC resistance was improved by increasing of the size and interspacing of η particles in matrix and grain boundary. The electrical conductivity increased with aging time, but SCF decreased due to the decrease of yield strength. This results mean increase of SCC resistance The optimum two-step aging condition in forged 7050 Al alloy was to be first aged at $120^{\circ}C$ for 6h and then finally aged at $175^{\circ}C$ for 12h.

  • PDF

An Evaluation Technique of Surface Roughness of Corroded Reinforcing Bar-in-Coils (코일철근의 표면 거칠기 물리량 평가 기술)

  • Roh, Young-Sook;Cho, Kang Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6551-6557
    • /
    • 2015
  • This paper discusses the surface roughness of corroded reinforcement rebar-in-coil focusing on the quantitative measurement technique using 3D scanner. Reinforcement rebar-in-coil was stacked in site for 0 day, 3 days, 7 days, 14 days and 21 days. And rebar-in-coil was corroded 0.04%, 0.3367%, 0.6157%, 0.7898%, and 1.1965% respectively. Using 3-dimensional scanner, each surface profile of reinforcement rebar-in-coil was established, and surface roughness was measured. Through the tests and analyses of corroded rebar-in-coil, the increase of fractal dimension for each rebar-in-coil was measured as 0.0216, 0.0235, 0.028, 0.0319, and 0.0455 for different stacked periods. Therefore, surface assessment technique using fractal dimension showed similar results with the actual corrosion rate.

Study on the Cathodic Protection Characteristics of Hot Water Boiler by Mg-Alloy Galvanic Anode(1) (Mg 합금 유전양극에 의한 온수Boiler의 음극방식특성에 관한 연구(1))

  • 임우조;윤병두
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.147-152
    • /
    • 2001
  • Corrosion damage of boiler, factory equipment and so forth occur quickly due to using of the polluted water, resulting in increasing leak accident. Especially, working life of hot water boiler using the polluted water becomes more short, and energy loss increases. The cathodic protection method is the most economical and reliable one to prevent corrosion damage of steel structures. Mg-base alloys galvanic anode protection of cathodic protection methode is suitable for the application of hot water boiler using water with high specific resistance such as tap water. This paper is studied on the cathodic protection characteristics of hot water boiler. In tap water solution, the measurement of cathodic protection potential according to the time elapsed is carried out, and behavior of cathodic polarization with current change is investigated. The main results obtained are as follows. In hot water boiler shell, the open circuit potential of base metal become less noble than that of weld Bone, and the current density of base metal becomes low than that of weld zone. The further distance from Mg-alloy galvanic anode, the higher cathodic protection potential of hot water boiler appears. And protective potential becomes high according to pass cathodic protection time and after 6∼10 days become stable.

  • PDF

MWCNT, silver nanoparticles, CuBTC를 사용한 염소 이온 센서 합성

  • Gwak, Byeong-Gwan;Park, Su-Bin;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.101-101
    • /
    • 2018
  • Quantitative measurement of chloride ion concentration has an important role in various fields of electrochemistry, medical science, biology, metallurgy, architecture, etc. Among them, its importance of architecture is ever-growing due to unexpected degradations of building structure. These situations are caused by corrosion of reinforced concrete (RC) structure of buildings. And chloride ions are the most powerful factors of RC structure corrosion. Therefore, precise inspection of chloride ion concentration must be required to increase the accuracy of durability monitoring. Multi-walled Carbon nanotubes (MWCNTs) have high chemical resistivity, large surface area and superior electrical property. Thus, it is suitable for the channels of electrical signals made by the sensor. Silver nanoparticles were added to giving the sensing property. CuBTC, one of the metal organic frameworks (MOFs), was employed as a material to improve the sensing property because of its hydrophilicity and high surface area to volume ratio. In this study, sensing element was synthesized by various chemical reaction procedures. At first, MWCNTs were functionalized with a mixture of sulfuric acid and nitric acid because of enhancement of solubility in solution and surface activation. And functionalized MWCNTs, silver nanoparticles, and CuBTC were synthesized on PTFE membrane, one by one. Electroless deposition process was performed to deposit the silver nanoparticles. CuBTC was produced by room temperature synthesis. Surface morphology and composition analysis were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS), respectively. X-ray photoelectron spectroscopy (XPS) was also performed to confirm the existence of sensing materials. The electrical properties of sensor were measured by semiconductor analyzer. The chloride ion sensing characteristics were confirmed with the variation of the resistance at 1 V.

  • PDF

The Influence of Hydrotalcite Intercalated with Benzoate on UV Stability of Acrylic Coating

  • Nguyen, Thuy Duong;Nguyen, Anh Son;Thai, Thu Thuy;Pham, Gia Vu;To, Thi Xuan Hang;Olivier, Marie-Georges
    • Corrosion Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.16-22
    • /
    • 2020
  • It is important to realize that benzoate was intercalated into hydrotalcite (HTC-Bz) by the co-precipitation method. In this case, acrylic coating with 0.5 wt% HTC-Bz was deposited on carbon steel using the spin coating method. Next, the HTC-Bz structure was characterized by Field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). In fact, an ultraviolet vision spectroscopy (UV-Vis) was used to determine the benzoate content in HTC-Bz, and the UV absorption ability of HTC-Bz. Using electrochemical techniques, water contact angle measurement, and thermal-gravimetric analysis, we compared the protective properties before and after QUV test, hydrophobicity and the thermal stability of acrylic coating containing HTC-Bz. The obtained results showed that HTC-Bz with a plate-like structure was successfully synthesized; benzoate was intercalated into the interlayer of hydrotalcite with a concentration of 28 wt%. Additionally, it was noted that HTC-Bz has an UV absorption peak at 225 nm. In conclusion, the addition of HTC-Bz enhanced the UV stability, hydrophobicity and the thermal stability of acrylic coating.

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

The Studies of Stability for Volatile Organic Compounds(VOCs) Generated from the Adhesives (접착제에서 발생하는 휘발성유기화합물(VOCs)에 대한 안정성 연구)

  • Lee, Hyeon Kyeong;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.243-254
    • /
    • 2015
  • In this study, the stability of the adhesive was determined through the Oddy Test that is Verification Test for potential damage by various materials. And to find the factor causing the corrosion of the metal samples, the adhesives and coatings those are usually used in the metal preservation process were selected and treated on the samples. Six kinds of adhesives and four kinds of metal specimens Fe, Pb, Cu, Ag were used. As results, the weight change showed high increasement in the rate of weight change 29.87% of Fe sample. The chromaticity measurement showed the high change value of the Cellulose-based adhesive. In case of the VOCs test from adhesive by using GC-MS, Acetic acid was detected from all six kinds of the adhesives. Compared to cellulose-based adhesives and the other adhesives, the amount of VOCs per 1mg concentration is higher than 900 times and was detected small amount of Formic acid. This is assumed to be facilitated by acid impurities and the light. This reaction was considered as the result of reducing a large amount of molecular and of generating a large amount of Nox. And thus the reacted sulfur changes was considered as the factor for causing corrosion.

Application of Acoustic Emission for Assessing Deterioration in Reinforced Concrete Beams (철근 콘크리트 빔의 노화도 평가를 위한 음향방출 기술의 응용)

  • Yoon, Dong-Jin;Park, Phi-Lip;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • The acoustic emission (AE) behavior of reinforced concrete beams tested under flexural loading was investigated to characterize and identify the source of damage. This research was aimed at identifying the characteristic AE response associated with micro-crack development, localized crack propagation, corrosion, and debonding of the reinforcing steel. Concrete beams were prepared to isolate the damage mechanisms by using plain, notched-plain, reinforced, and corroded-reinforced specimens. The beams were tested using four-point cyclic step-loading. The AE response was analyzed to obtain key parameters such as the time history of AE events, the total number and rate of AE events, and the characteristic features of the waveform. Initial analysis of the AE signal has shown that a clear difference in the AE response is observed depending on the source of the damage. The Felicity ratio exhibited a correlation with the overall damage level, while the number of AE events during unloading can be an effective criterion to estimate the level of corrosion distress in reinforced concrete structures. Consequently, AE measurement characterization appears to provide a promising approach for estimating the level of deterioration in reinforced concrete structure.

  • PDF

Evaluation of Nondestructive Evaluation Size Measurement for Integrity Assessment of Axial Outside Diameter Stress Corrosion Cracking in Steam Generator Tubes (증기발생기 전열관 외면 축균열 건전성 평가를 위한 비파괴검사 크기 측정 평가)

  • Joo, Kyung-Mun;Hong, Jun-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

Effects of alloy elements on electrochemical characteristics improvement of stainless steel in sea water (해수환경하에서 스테인리스강의 전기화학적 특성 개선을 위한 합금원소의 영향)

  • Lee, Jung-Hyung;Choi, Yong-Won;Jang, Seok-Ki;Kim, Seong-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.890-899
    • /
    • 2014
  • Austenitic stainless steel is widely used in various industries due to its excellent corrosion resistance. However, Cr carbides precipitation along the grain boundaries after heat treatment or welding may develop Cr depleted zone, which acts as a preferential site for intergranular corrosion attack. To resolve this, carbon stabilizing element such as Ti or Nb are added to suppress formation of Cr carbides. However, there are few reports on corrosion characteristics under seawater environment of the stabilized stainless steel. This study investigated the effects of alloying contents on the electrochemical characteristics in seawater of stainless steel containing stabilizing element(Ti and Nb). To achieve this, the changes on the microstructure due to alloying were observed with microscope, and the electrochemical characteristics were determined by measurement of natural potential and potentiodynamic polarization experiments. The microscopic observation revealed that all specimens had inclusions other than the austenite matrix phase due to the addition of alloying elements. Such inclusions are considered to have different electrochemical characteristics from those of the matrix, and thus a clear distinction was found according to the type of stabilizers and the contents. The results of this study suggest that it is important to consider the effects of alloying contents on the electrochemical characteristics in seawater with the addition of Ti or Nb into austenitic stainless steel.