• 제목/요약/키워드: Corrosion level

검색결과 346건 처리시간 0.023초

치과주조용 비귀금속 합금의 금속 용출 수준 (Concentration of elemental ions released from non-precious dental casting alloys)

  • 사공준;박수철
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.1-17
    • /
    • 2013
  • Purpose: This study was to assess the extents of the release of metals from the non-precious alloys used for dental casting by measuring the differences in the extents of the release of metals by types of alloys, pH level and elapsed time. Methods: Uniform-sized specimens(10 each) were prepared according to the Medical Device Standard of the Korea Food and Drug Administration(2010) and International Standard Organization(ISO22674, 2006), using four types of alloys(one type of Ni-Cr and one type of Co-Cr used for fixed prosthesis, and one type of Ni-Cr and one type of Co-Cr used for removable prosthesis). A total of 12 metal-release tests were performed at one-day, three-day, and two-week intervals, for up to 20 weeks. The metal ions were quantified using an Inductively Coupled Plasma-Atomic Emission Spectrometer. Results: The results showed that the extent of corrosion was higher in the ascending order of Jdium-$100^{(R)}$, Bellabond-$Plus^{(R)}$, Starloy-$C^{(R)}$, and Biosil-$F^{(R)}$. The lower the pH and the longer the elapsed time were, the greater the increase in metal corrosion. At pH 2.4, the release of Ni from Jdium-$100^{(R)}$, a Ni-Cr alloy, was up to 15 times greater than the release of Co from the Co-Cr alloy from two weeks over time, indicating that the Ni-Cr alloy is more susceptible to corrosion than the Co-Cr alloy. Conclusion: It is recommended that Co-Cr alloy, which is highly resistant to corrosion, be used for making dental prosthesis with a non-precious alloy for dental casting, and that non-precious alloy prosthesis be designed in such a way as to minimize the area of its oral exposure. For patients with non-precious alloy prostheses, a test of the presence or absence of periodontal tissue inflammation or allergic reaction around the prosthesis should be performed via regular examination, and education on the good management of the prosthesis is needed.

나무재료가 금속부식(金屬腐蝕)에 미치는 영향(影向) - Oddy test - (Effects of Wood Materials on Metal Corrosion - Oddy test -)

  • 이승은;노현숙;이용희
    • 박물관보존과학
    • /
    • 제5권
    • /
    • pp.31-36
    • /
    • 2004
  • 본 실험은 현재 박물관에서 사용하고 있거나 사용 검토 중이던 목재수종 6종(물푸레나무, 삼나무, 흑호두나무, 솔송나무, 오동나무, 단풍나무)을 대상으로 금속부식 영향을 조사한 것이다. 부식 테스트의 방법으로는 실험하고자 하는 재료와 test 시편(금속시편)을 일정 온습도에서 장시간 노출시키면서 재료가 시편에 미치는 영향을 관찰하는 Oddy test를 사용하였다. 6종의 나무 자재를 대상으로 실시한 Oddy test 결과 수종에 따라 금속부식의 형태가 조금씩 다르게 나타났으며, blank를 제외한 대부분의 철(Fe)과 납(Pb)시편에서는 표면전체에 부식이 발생하였다. 또한 구리(Cu)시편에서도 정도는 다르지만 모든 시편에서 조금씩 변색이 된 것을 관찰할 수 있었다.

가압기 지지대 볼트 연결부의 건전성 평가에 관한 연구 (The Assessment for Coupling Integrity of Pressurizer Support Bolting)

  • 조남진;김우창;김학중
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.26-31
    • /
    • 2013
  • 원전의 가압기 지지대에 사용되는 볼트는 설계 시 안전율 측면에서 충분한 경도의 볼트를 사용하지만, 현장실사를 통해 허용 경도 범위를 초과하는 볼트가 일부 확인되었다. 이러한 높은 경도의 볼트는 응력부식 및 재료의 파괴인성이 취약하고, 가압기는 부식에 취약한 환경이므로 이 부분에 대한 검토가 필요하다. 따라서 본 연구에서는 현장실사를 통해 원전 가압기 지지대에 사용되는 볼트의 경도를 측정하였고, 이를 통해 응력부식과 부재의 파괴인성에 의한 균열을 제한할 수 있는 최대 허용응력을 계산하였다. 또한 정상운전 및 사고운전 시 발생할 수 있는 지지대 볼트의 응력을 수치해석 프로그램인 ANSYS를 사용하여 예측하였고, 이 응력이 응력부식을 제한할 수 있는 최대 허용응력 내에 있는 지 검토하였다. 검토 결과 정상 및 사고운전 조건에서 볼트의 응력은 응력부식에 대해 허용응력 안전 기준치를 만족하는 것으로 나타났다. 그러나 향후 가압기 지지대의 구조물 체결방법을 체결 절차에 반영하여 정비 시 가압기의 건전성을 확보할 수 있도록 검토가 필요하다.

초단유리섬유가 PSC 그라우트의 부식저항성능에 미치는 영향 (Effect of Milled Glass Fibers on Corrosion Resistance of PSC Grout Mortar)

  • 문도영;김상운;김동주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.37-45
    • /
    • 2015
  • 본 실험 논문은 초단유리섬유(milled glass fibers)가 혼입된 PSC용 그라우트 몰탈의 강재부식성능을 평가하였다. 초단유리섬유를 함유한 배합이 PSC 그라우트 몰탈로서 소요성능을 만족시키는지를 확인하기 위하여 유하시간, 블리딩 및 압축강도를 측정하였다. 초단유리 섬유를 함유한 몰탈의 부식저항 성능은 염소이온 확산시험, 몰탈 흡수시험과 표면전기저항 측정 결과에 근거하여 수행되었다. 시험결과, 초단유리가 혼입된 모든 배합은 OPC만 사용된 배합에 비하여 그라우트의 부식저항성능을 개선시키는 것으로 확인되었다. 다만, 초단유리섬유를 사용함으로서 유하시간은 단축되지만 블리딩이 발생하여 소요성능을 만족하지 못하는 것으로 확인되었다. 그러므로 PSC 그라우트에 적합한 초단유리섬유배합이 되기 위해서는 물-바인더비의 조정이 필요한 것으로 판단된다.

A487 주강품의 C 및 Cr/Mo 함량 변화에 따른 기계적 및 부식 특성 (Mechanical and Corrosion Properties of A487 Cast with Different C and Cr/Mo Contents)

  • 정우진;정대호;이영철;이재현;김상식
    • 한국주조공학회지
    • /
    • 제35권3호
    • /
    • pp.45-52
    • /
    • 2015
  • The effect of different C and Cr/Mo contents, which were varied within the range allowed in the relevant specification, on the mechanical and corrosion properties of A487 alloy cast steel were examined. The increase in strength level with increasing C content and the decrease in strength along with the increase in tensile elongation with decreasing Cr/Mo contents were observed in A487 alloys with different C and Cr/Mo contents. At room temperature, the decrease in Cr/Mo content was beneficial in improving the impact properties of A487 alloy, with no notable difference in absorbed energy with varying C content. The impact properties of A487 alloy at $-60^{\circ}C$, on the other hand, greatly improved with the increase in C and the decrease in Cr/Mo contents. The corrosion behavior of A487 alloys in 3.5% NaCl solution did not show any meaningful change with different C and Cr/Mo contents.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • 제27권5호
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

원자로 내부구조물 균열개시 민감도에 미치는 영향인자 고찰 (Review of Factors Affecting IASCC Initiation of Stainless Steel in PWRs)

  • 황성식;최민재;김성우;김동진
    • Corrosion Science and Technology
    • /
    • 제20권4호
    • /
    • pp.210-229
    • /
    • 2021
  • To safely operate domestic nuclear power plants approaching the end of their design life, the material degradation management strategy of the components is important. Among studies conducted to improve the soundness of nuclear reactor components, research methods for understanding the degradation of reactor internals and preparing management strategies were surveyed. Since the IGSCC (Intergranular Stress Corrosion Cracking) initiation and propagation process is associated with metal dissolution at the crack tip, crack initiation sensitivity was decreased in the hydrogenated water with decreased crack sensitivity but occurrence of small surface cracks increased. A stress of 50 to 55% of the yield strength of the irradiated materials was required to cause IASCC (Irradiation Assisted Stress Corrosion Cracking) failure at the end of the reactor operating life. In the threshold-stress analysis, IASCC cracks were not expected to occur until the end of life at a stress of less than 62% of the investigated yield strength, and the IASCC critical dose was determined to be 4 dpa (Displacement Per Atom). The stainless steel surface oxide was composed of an internal Cr-rich spinel oxide and an external Fe and Ni-rich oxide, regardless of the dose and applied strain level.

Damage classification of concrete structures based on grey level co-occurrence matrix using Haar's discrete wavelet transform

  • Kabir, Shahid;Rivard, Patrice
    • Computers and Concrete
    • /
    • 제4권3호
    • /
    • pp.243-257
    • /
    • 2007
  • A novel method for recognition, characterization, and quantification of deterioration in bridge components and laboratory concrete samples is presented in this paper. The proposed scheme is based on grey level co-occurrence matrix texture analysis using Haar's discrete wavelet transform on concrete imagery. Each image is described by a subset of band-filtered images containing wavelet coefficients, and then reconstructed images are employed in characterizing the texture, using grey level co-occurrence matrices, of the different types and degrees of damage: map-cracking, spalling and steel corrosion. A comparative study was conducted to evaluate the efficiency of the supervised maximum likelihood and unsupervised K-means classification techniques, in order to classify and quantify the deterioration and its extent. Experimental results show both methods are relatively effective in characterizing and quantifying damage; however, the supervised technique produced more accurate results, with overall classification accuracies ranging from 76.8% to 79.1%.

전남 무안지역에 분포하는 석회질암의 용식작용과 지반침하 (Corrosion of Calcareous Rocks and Ground Subsidence in the Muan Area, Jeonnam, Korea)

  • 안건상
    • 암석학회지
    • /
    • 제16권2호
    • /
    • pp.47-58
    • /
    • 2007
  • 본 연구에서는 2005년 6월 지반침하가 발생한 전남 무안군 무안읍 교촌리 일대의 기반암의 분포를 조사하고, 지반침하의 원인인 석회질암의 용식작용과 지반침하 현상을 추적했다. 연구지역의 지표에서는 운모편암과 유문암이 관찰되나, 지하에는 크고 작은 공동을 갖는 석회질암이 분포한다. 또한 지반침하지역 북측의 우회도로를 따라 폭이 최대 300 m이고, 길이가 4 km 이상의 두꺼운 석회암 층이 분포하고 있다. 이러한 석회암의 분포 규명은 이후에 발생할 수 있는 석회공동에 의한 지반침하를 예측하는데 매우 유용한 자료가 될 것이다. 이 지역 석회질암은 심한 전단변형을 받아 소규모의 습곡과 단층으로 교란되어 있다. 석회질암층에 형성된 습곡의 배사 부분에 소규모의 공동들이 자주 발견된다. 이는 습곡작용 시 약화된 석회질이 용해되어 공동이 형성된 것으로 판단된다. 또한 석회질암 내에는 다양한 두께의 편암이 협재되어 있는데, 이 편암은 주로 판상광물(녹니석, 운모)과 석영으로 구성되어 있다. 풍화된 암석 시료의 절단면을 보면 편암의 흑운모가 녹니석으로 변질되고, 이어서 편암 주변부터 방해석이 용식되어가는 현상이 관찰된다. 이는 석회질암에 협재된 판상광물 틈새로 지하수가 침투하여 석회암의 용식이 시작되었음을 시사한다. 즉, 위의 두 가지 메커니즘에 의해 무안지역의 석회질암층에서는 공동이 생성되었을 것으로 보인다. 저수지(불무재)의 매립과 농업용수의 과다 양수와 같은 이유로 공동을 지지하는 지하수가 고갈되거나, 공통퇴적물이 유실되어 지반침하가 일어난 것으로 해석된다.

습윤 상태에서의 반전위를 이용한 철근 부식과 영향 인자 간의 상관성 분석 (Relationship between Corrosion in Reinforcement and Influencing Factors Using Half Cell Potential Under Saturated Condition)

  • 정기찬;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제9권2호
    • /
    • pp.191-199
    • /
    • 2021
  • 본 연구에서는 3가지 수준의 물-시멘트 비, 상부 주입 염수 농도, 피복두께를 고려하여 반전위값과 영향인자들 간의 상관성을 분석하였다. 피복두께가 증가할수록 반전위값이 증가(+ 방향 : 부식 억제)하여 부식 저항성이 증가하는 것을 확인할 수 있었으며 평가 기준에 따르면 피복두께 60mm를 갖는 시편의 경우 비교적 부식이 적게 일어난 것으로 판단된다. 이는 피복두께가 외부 열화인자에 대한 효과적인 방어기구로서 작용한 것이 원인으로 사료된다. 상부 주입 염수 농도가 0%인 경우 모든 경우에서 부식이 발생하지 않는 것으로 판단되지만, 염수 농도 3.5% 및 7.0%의 경우 부식이 진전된 것으로 판단된다. 비교적 높은 단위 결합재량이 확보된 배합에서 부식 저감에 유리한 모니터링 결과가 도출되었으며, 부식 영향인자와 반전위값 간의 상관성을 평가하고자 다중 회귀분석을 수행하였다. 해당 예측식의 결정계수는 0.97로 매우 높은 수준으로 나타났지만 사용한 표본의 수가 제한적이고 특정 시점의 결과만이 이용된 한계점이 존재하였다. 추가적인 모니터링 수행 및 시편 해체 후 관련 데이터와의 상관성 분석을 통해 더욱 합리적인 예측식의 도출이 가능해 질 것으로 사료된다.