• Title/Summary/Keyword: Corrosion level

Search Result 348, Processing Time 0.026 seconds

An Assesment of the Gas Pipeline Reliability Using Corrosion based Composite Failure (부식기반 복합고장을 고려한 가스배관의 신뢰도 평가)

  • Kim, Seong-Jun;Kim, Dohyun;Kim, Woosik;Kim, Young-Pyo;Kim, Cheolman
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.4
    • /
    • pp.739-754
    • /
    • 2019
  • Purpose: The purpose of this paper is to develop a reliability estimation procedure for the underground gas pipeline in the presence of corrosion defects. Methods: Corrosion is one of the major causes of the gas pipeline failure. Several failure forms caused by corrosion have been studied. Among them, small leak and burst are considered in this paper. The composite failure of the two is defined by limit state function, and it is expressed with pipe parameters. Given a modified corrosion dataset, in order to obtain reliability estimations, the method of first order and second moment is adopted because of its simplicity. The computation processes are conducted with MATLAB coding. Results: According to numerical results, the probability of composite failure is affected by both small leak and burst. In particular, when corrosion depth stays at low level, it is consistent with the probability of burst failure. On the contrary, it is more influenced by the small leak failure as corrosion depth is increasing. In such case, the probability of composite failure is fast approaching to the safety limit. Conclusion: By considering the composite failure, more practical predictions of remaining life can be obtained. The proposed method is useful for maintenance planning of the underground gas pipeline.

Fuzzy methodology application for modeling uncertainties in chloride ingress models of RC building structure

  • Do, Jeongyun;Song, Hun;So, Seungyoung;Soh, Yangseob
    • Computers and Concrete
    • /
    • v.2 no.4
    • /
    • pp.325-343
    • /
    • 2005
  • Chloride ingress is a common cause of deterioration of reinforced concrete located in coastal zone. Modeling the chloride ingress is an important basis for designing reinforced concrete structures and for assessing the reliability of an existing structure. The modeling is also needed for predicting the deterioration of a reinforced structure. The existing deterministic solution for prediction model of corrosion initiation cannot reflect uncertainties which input variables have. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. There are a lot of prediction model for predicting the time of reinforcement corrosion of structures exposed to chloride-induced corrosion environment. In this work, RILEM model formula and Crank's solution of Fick's second law of diffusion is used. The parameters of the models are regarded as fuzzy numbers with proper membership function adapted to statistical data of the governing parameters instead of random variables of probabilistic modeling of Monte Carlo Simulation and the fuzziness of the time to corrosion initiation is determined by the fuzzy arithmetic of interval arithmetic and extension principle. An analysis is implemented by comparing deterministic calculation with fuzzy arithmetic for above two prediction models.

The Application of Non-phosphorous AEC Program in Cooling Water Systems of Petrochemical Industry

  • Li, Dagang;Hong, Mike;He, Gaorong
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.16-21
    • /
    • 2008
  • A non-phosphorous program employing an alkyl epoxy carboxylate (AEC) has been successfully applied to petrochemical and other large industrial open recirculating cooling water systems. AEC is a patented non-phosphorous calcium carbonate scale inhibitor that has demonstrated better scale inhibition abilities than traditional organic phosphonates. In addition to its antiscalant properties, AEC inhibits carbon steel corrosion when used at high dosages. AEC can be combined with zinc to form a non-phosphorous program with very low levels of phosphate to provide an environmentally acceptable program. In actual applications, the total phosphate developed in the cooling system from cycling the makeup is below 1 ppm as $PO_4$. This level has complied with the highest standards of wastewater discharge limitations. The performance of two AEC/Zinc applications is reviewed. In both cases excellent corrosion and scale control were achieved with AEC/Zinc programs. One case history details the performance with a low hardness water (100 ppm calcium, as $CaCO_3$) operating at 8-10 cycles of concentration. The corrosive nature of the water and the long retention time of the system stressed both the corrosion and scale control capabilities of the program. The second case history demonstrates the performance of the program with a moderate hardness water (400-600 ppm calcium, as $CaCO_3$), but under harsh conditions of high temperature and low flow. The AEC/zinc combination has been found to be highly effective in controlling the corrosion of ferrous metals. AEC can provide good corrosion inhibition at high concentrations, while zinc is known to be an excellent cathodic inhibitor. The combination of the two inhibitors not only provides a synergistic blend that is effective over a wide range of operating conditions, but also is environmentally friendly.

Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System (지역난방 냉각수 배관의 용접부 파손 분석)

  • Jeong, Joon-Cheol;Kim, Woo-Cheol;Kim, Kyung Min;Sohn, Hong-Kyun;Kim, Jung-Gu;Lee, Soo-Yeol;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

Experimental investigation on durability performance of rubberized concrete

  • Guneyisi, Erhan;Gesoglu, Mehmet;Mermerdas, Kasim;Ipek, Suleyman
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.193-207
    • /
    • 2014
  • The study presented herein aims to investigate the durability related properties of rubberized concrete. Two types of waste scrap tire rubber were used as fine and coarse aggregate, respectively. The rubber was replaced with aggregate by three crumb rubber and tire chips levels of 5, 15, and 25% for the rubberized concrete productions. In order to improve the transport properties and corrosion resistance of rubberized concretes, SF was replaced with cement at 10% replacement level by weight of total binder content. The transport properties of the rubberized concretes were investigated through water absorption, gas permeability, and water permeability tests. The corrosion behavior of reinforcing bars embedded in plain and silica fume based rubberized concretes was investigated by linear polarization resistance (LPR) test. The results indicated that the utilization of SF in the rubberized concrete production enhanced the corrosion behavior and decreased corrosion current density values. Moreover, the reduction in the water and gas permeability coefficients was observed by the incorporation of SF in plain and especially rubberized concretes.

Numerical modeling of concrete cover cracking due to steel reinforcing bars corrosion

  • Mirzaee, Mohammad Javad;Alaee, Farshid Jandaghi;Hajsadeghi, Mohammad;Zirakian, Tadeh
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.693-700
    • /
    • 2017
  • Concrete cover cracking due to the corrosion of steel reinforcing bars is one of the main causes of deterioration in Reinforced Concrete (RC) structures. The oxidation level of the bars causes varying levels of expansion. The rebar expansions could lead to through-thickness cracking of the concrete cover, where depending on the cracking characteristics, the service life of the structures would be affected. In this paper, the effect of geometrical and material parameters, i.e., concrete cover thickness, reinforcing bar diameter, and concrete tensile strength, on the required pressure for concrete cover cracking due to corrosion has been investigated through detailed numerical simulations. ABAQUS finite element software is employed as a modeling platform where the concrete cracking is simulated by means of eXtended Finite Element Method (XFEM). The accuracy of the numerical simulations is verified by comparing the numerical results with experimental data obtained from the literature. Using a previously proposed empirical equation and the numerical model, the time from corrosion initiation to the cover cracking is predicted and then compared to the respective experimental data. Finally, a parametric study is undertaken to determine the optimum ratio of the rebar diameter to the reinforcing bars spacing in order to avoid concrete cover delamination.

Evaluation of Plasma Spray Hydroxy Apatite coatings on Metallic Materials

  • Take, S.;Mitsui, K.;Kasahara, M.;Sawai, R.;Izawa, S.;Nakayama, M.;Itoi, Y.
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.286-290
    • /
    • 2007
  • Biocompatible Hydroxy apatite (HAp) coatings on metallic substrate by plasma spray techniques have been developed. Long-term credibility of plasma spray HAp coatings has been evaluated in physiological saline by electrochemical measurements. It was found that the corrosion resisitance of SUS316L based HAp/Ti conbined coatings was excellent even after more than 10 weeks long-term immersion. It was shown that postal heat treatment improved both the crystallinity and corrosion resistance of HAp. By lowering cooling rate during heat treatment process, less cracks produced in HAp coating layer, which lead to higher credibility of HAp during immersion in physiological saline. The ICP results showed that the dissolution level of substrate metallic ions was low and HAp coatings produced in this research can be acceptable as biocompatible materials. Also, the concentration of dissolved ions from HAp coatings with postal heat treatment was lower compared to those from samples without postal heat treatment. The adherence of HAp coatings with Ti substrate and other mechanical properties were also assessed by three-point bending test. The poor adhesion of HAp coating to titanium substrate can be improved by introducing a plasma spray titanium intermediate layer.

Failure Shape of RC Columns by The Degree of Corrosion of Reinforcement (철근부식정도에 따른 기둥의 파괴형태)

  • Song, Han-Beom;Oh, Sang-Hoon;Yi, Waon-Ho;Ryu, Hong-Sik;Kang, Dae-Eon;Tae, Kyung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.61-64
    • /
    • 2008
  • Reinforced Concrete structures are constructed under the basic assumption of perfect bonding between steel and concrete. The corrosion of steel in the reinforced concrete columns results in the excessive cracks and gradual deterioration of concrete between steel and concrete. The cyclic loading test was conducted with the three corrosion rates in the laboratory. Throughout this test, it is investigated a bond behavior of reinforced concrete columns under a steel corrosion. Main variables of the test are a corrosion of steel reinforcement and a level of stress.

  • PDF

A Study on the Stress Corrosion Cracking Evaluation for Weld Joint of TMCP steel by SP-SSRT Method (SP-SSRT법에 의한 TMCP강 용접부의 응력부식균열 평가에 관한 연구)

  • 유효선;정희돈;정세희
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.46-54
    • /
    • 1997
  • The object of this paper is to evaluate SCC(stress corrosion cracking) susceptibility for parent metal and bond line region of weld joints which have the various weld heat input condtions in TMCP(thermo-mechanical control process) steel by SP-SSRT(small punch-slow strain rate test) method. And the SCC test results of TMCP steel are compared with those of the conventional HT50 steel which has te almost same tensile strength level like TMCP steel. The loading rate used was $3\times10^{-4}$mm/min and the corrosive environment was synthetic sea water. According to the test results, in the case of parent metal, TMCP steel showed higher SCC susceptibility than HT50 steel because of the high plastic strain level of ferrite microstructure obtained by accelerated cooling. And in the case of bond line, the both TMCP steel and HT50 steel showed low load-displacement behaviors and higher SCC susceptibility above 0.6. These results may be caused by theembrittled martensite structure on HT50 steel and by the coarsened grain and the proeutectoid ferrite structure obtained by the impart of accelerated cooling effect on TMCP steel.

  • PDF

Experimental Study of Bond Characteristics on Slab Reinforcement Corroded Before and After Casting (타설 전과 후에 부식시킨 슬래브 시험체의 철근 부착특성에 관한 실험적 연구)

  • Kim, Dae-Il;Cho, Seung-Ho;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1035-1040
    • /
    • 2001
  • Recently, Sea-sand containing high levels of chloride is being applied to on reinforced concrete structures due to the exhaustion of river-sand and environmental problems, which affects directly corrosion of rebar in the RC structures. In this paper, characteristics of corroded rebar before and after casting were studied. Test results showed that bond strength of rebar corroded after casting was decreased with increase of corrosion level more rapidly than that of rebar corroded before casting.

  • PDF