• Title/Summary/Keyword: Correlation identification

Search Result 689, Processing Time 0.027 seconds

A Study on Correlation between ARIA, TNSS and Nasal Endoscopy as Instruments of Evaluation for Allergic Rhinitis (비내시경 소견의 알레르기비염 분류 도구와 중증도 평가도구의 상관성 연구)

  • Lee, Kyu-Jin;Yun, Young-Hee;Kim, Kyu-Seok;Jang, Soo-Bin;Choi, In-Hwa;Ko, Seong-Gyu
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.28 no.1
    • /
    • pp.109-118
    • /
    • 2015
  • Objectives : We performed a clinical study to investigate characteristics of pattern identifications using nasal endoscopy for allergic rhinitis (AR). Methods : We assessed 32 patients with allergic rhinitis using nasal endoscopy, classifications of allergic rhinitis and it's impact on asthma (ARIA) and total nasal symptom score (TNSS). Results : The watery rhinorrhea score of nasal endoscopy was significantly high in 'persistent and moderate/severe' group (P<0.05). Patients were classified as rhinorrhea group and nasal obstruction group according to nasal endoscopy. TNSS and rhinorrhea score was significantly high in rhinorrhea group (P<0.05). Conclusions : The result may provide that the watery rhinorrhea of nasal endoscopy is useful as 'Cold' and 'Deficiency' pattern identification diagnostic tool.

Development of Clinical Protocol on the Correlation Between Disease Cause Pattern Identification and Pulse Wave Variables (병인변증과 요골동맥 맥상파의 특성 파악을 위한 탐색적 관찰 연구 : 임상시험 프로토콜 개발)

  • Kim, Jihye;Yu, Hana;Ku, Boncho;Kim, Hyunho;Kim, Jongyeol;Jeon, Youngju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.662-667
    • /
    • 2014
  • The purpose of this clinical study is to develop structured clinical trial protocol and guideline for improvement of safety, useful and effective of pulse diagnosis devices. As a first step, papers on pulse diagnosis and pulse diagnosis devices from 2001 and 2013 were systematically reviewed. In the next step, we have collected the opinions from the specialists, companies, and statistician in pulse diagnosis to evaluate the current condition, the state and problem of domestic clinical trial cases of pulse diagnosis device. And we have to created protocol and case report form (CRF) in regards to site condition and characteristics of pulse diagnosis devices, and showed the guideline of eligibility criteria, operation process, investigation items, evaluation items and so on. This clinical protocol will become a basic information for a researcher in designing or performing a clinical study of pulse diagnosis devices, and be used as a useful material during acquisition of good clinical data. Furthermore, we hope to enhance the invigoration of pulse diagnosis clinical trials and the performance improvement of pulse diagnosis devices.

Identification of Structural Defects in Rail Fastening Systems Using Flexural Wave Propagation (굽힘파 전파 특성을 이용한 레일체결장치의 구조 결함 진단)

  • Park, Jeongwon;Park, Junhong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.38-43
    • /
    • 2014
  • An experimental method based on flexural wave propagation is proposed for identification of structural damage in rail fastening systems. The vibration of a rail clamped and supported by viscoelastic pads is significantly influenced by dynamic support properties. Formation of a defect in the rail fastening system induces changes in the flexural wave propagation characteristics owning to the discontinuity in the structural properties. In this study, frequency-dependent support stiffness was measured to monitor this change by a transfer function method. The sensitivity of wave propagation on the defect was measured from the potential energy stored in a continuously supported rail. Further, the damage index was defined as a correlation coefficient between the change in the support stiffness and the sensitivity. The defect location was identified from the calculated damage index.

Piezo-activated guided wave propagation and interaction with damage in tubular structures

  • Lu, Ye;Ye, Lin;Wang, Dong;Zhou, Limin;Cheng, Li
    • Smart Structures and Systems
    • /
    • v.6 no.7
    • /
    • pp.835-849
    • /
    • 2010
  • This study investigated propagation characteristics of piezo-activated guided waves in an aluminium rectangular-section tube for the purpose of damage identification. Changes in propagating velocity and amplitude of the first wave packet in acquired signals were observed in the frequency range from 50 to 250 kHz. The difference in guided wave propagation between rectangular- and circular-section tubes was examined using finite element simulation, demonstrating a great challenge in interpretation of guided wave signals in rectangular-section tubes. An active sensor network, consisting of nine PZT elements bonded on different surfaces of the tube, was configured to collect the wave signals scattered from through-thickness holes of different diameters. It was found that guided waves were capable of propagating across the sharp tube curvatures while retaining sensitivity to damage, even that not located on the surfaces where actuators/sensors were attached. Signal correlation between the intact and damaged structures was evaluated with the assistance of a concept of digital damage fingerprints (DDFs). The probability of the presence of damage on the unfolded tube surface was thus obtained, by which means the position of damage was identified with good accuracy.

Recent Development of Rapid and Automation Technology for Food Microbiological Examination

  • Hiroshi Kurata
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1996.06a
    • /
    • pp.33-33
    • /
    • 1996
  • Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.

Metabolic classification of herb plants by NMR-based metabolomics

  • Kim, Hee-Eun;Choi, Ye Hun;Choi, Kwang-Ho;Park, Ji Su;Kim, Hyeon Su;Jeon, Jun Hyeok;Heu, Min Soo;Shin, Dong-Seon;Lee, Joon-Hwa
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.16 no.2
    • /
    • pp.91-102
    • /
    • 2012
  • Metabolomics is the systematic identification and quantification of all metabolites in an organism or biological sample. NMR has been used as a major application tool in plant metabolomics such as quality control, chemotaxonomy, and analysis of genetically modified plants. Herbal medicines are the important therapeutics and are used to manage common diseases such as cold, inflammation, pain, heart diseases, liver cirrhosis, diabetes and central nerve system diseases. Herb plants include various kinds of species such as geranium, mint, and thyme and so on and contain different kinds of metabolites. We performed NMR-based metabolomics study on the seven different species of herb plants using $^1H$ NMR experiments and OPLS-DA to understand the correlation between the classification of herb plants and their metabolite contents. This study showed clear metabolic discrimination among various herb plants. This metabolmics study found several diagnostic NMR signals which are able to be used as bio-markers for identification of the specific herb plants among various species. Clear metabolic discrimination of herb plants suggests three chemotaxonomic groups of herb species.

Instrumentation on structural health monitoring systems to real world structures

  • Teng, Jun;Lu, Wei;Wen, Runfa;Zhang, Ting
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.151-167
    • /
    • 2015
  • Instrumentation on structural health monitoring system imposes critical issues for applying the structural monitoring system to real world structures, for which not only on the configuration and geometry, but also aesthetics on the system to be monitored should be considered. To illustrate this point, two real world structural health monitoring systems, the structural health monitoring system of Shenzhen Vanke Center and the structural health monitoring system of Shenzhen Bay Stadium in China, are presented in the paper. The instrumentation on structural health monitoring systems of real world structures is addressed by providing the description of the structure, the purpose of the structural health monitoring system implementation, as well as details of the system integration including the installations on the sensors and acquisition equipment and so on. In addition, an intelligent algorithm on stress identification using measurements from multi-region is presented in the paper. The stress identification method is deployed using the fuzzy pattern recognition and Dempster-Shafer evidence theory, where the measurements of limited strain sensors arranged on structure are the input data of the method. As results, at the critical parts of the structure, the stress distribution evaluated from the measurements has shown close correlation to the numerical simulation results on the steel roof of the Beijing National Aquatics Center in China. The research work in this paper can provide a reference for the design and implementation of both real world structural health monitoring systems and intelligent algorithm to identify stress distribution effectively.

Bearing Faults Identification of an Induction Motor using Acoustic Emission Signals and Histogram Modeling (음향 방출 신호와 히스토그램 모델링을 이용한 유도전동기의 베어링 결함 검출)

  • Jang, Won-Chul;Seo, Jun-Sang;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.17-24
    • /
    • 2014
  • This paper proposes a fault detection method for low-speed rolling element bearings of an induction motor using acoustic emission signals and histogram modeling. The proposed method performs envelop modeling of the histogram of normalized fault signals. It then extracts and selects significant features of each fault using partial autocorrelation coefficients and distance evaluation technique, respectively. Finally, using the extracted features as inputs, the support vector regression (SVR) classifies bearing's inner, outer, and roller faults. To obtain optimal classification performance, we evaluate the proposed method with varying an adjustable parameter of the Gaussian radial basis function of SVR from 0.01 to 1.0 and the number of features from 2 to 150. Experimental results show that the proposed fault identification method using 0.64-0.65 of the adjustable parameter and 75 features achieves 91% in classification performance and outperforms conventional fault diagnosis methods as well.

The Use of Near Infrared Reflectance Spectroscopy (NIRS) for Broiler Carcass Analysis

  • Hsu, Hua;Zuidhof, Martin J.;Recinos-Diaz, Guillermo;Wang, Zhiquan
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1510-1510
    • /
    • 2001
  • NIRS uses reflectance signals resulting from bending and stretching vibrations in chemical bonds between carbon, nitrogen, hydrogen, sulfur and oxygen. These reflectance signals are used to measure the concentration of major chemical composition and other descriptors of homogenized and freeze-dried whole broiler carcasses. Six strains of chicken were analyzed and the NIRS model predictions compared to reference data. The results of this comparison indicate that NIRS is a rapid tool for predicting dry matter (DM), fat, crude protein (CP) and ash content in the broiler carcass. Males and females of six commercial strain crosses of broiler chicken (Gallus domesticus) were used in this study (6$\times$2 factorial design). Each strain was grown to 16 weeks of age, and duplicate serial samples were taken for body composition analysis. Each whole carcass was pressure-cooked, homogenized, and a representative sample was freeze-dried. Body composition determined as follows: DM by oven dried method at 105$^{\circ}C$ for 3 hours, fat by Mojonnier diethyl ether extraction, CP by measuring nitrogen content using an auto-analyzer with Kjeldhal digest and ash by combustion in a muffle furnace for 24 hour at 55$0^{\circ}C$. These homogenized and freeze-dried carcass samples were then scanned with a Foss NIR Systems 6500 visible-NIR spectrophotometer (400-2500nm) (Foss NIR Systems, Silver Spring, MD., US) using Infra-Soft-International, ISI, WinISl software (ISI, Port Matilda, US). The NIRS spectra were analyzed using principal component (PC) analysis. This data was corrected for scatter using standard normal “Variate” and “Detrend” technique. The accuracy of the NIRS calibration equations developed using Partial Least Squares (PLS) for predicting major chemical composition and carcass descriptors- such as body mass (BM), bird dry matter and moisture content was tested using cross validation. Discrimination analysis was also used for sex and strain identification. According to Dr John Shenk, the creator of the ISI software, the calibration equations with the correlation coefficient, $R^2$, between reference data and NIRS predicted results of above 0.90 is excellent and between 0.70 to 0.89 is a good quantifying guideline. The excellent calibration equations for DM ($R^2$= 0.99), fat (0.98) and CP (0.92) and a good quantifying guideline equation for ash (0.80) were developed in this study. The results of cross validation statistics for carcass descriptors, body composition using reference methods, inter-correlation between carcass descriptors and NIRS calibration, and the results of discrimination analysis for sex and strain identification will also be presented in the poster. The NIRS predicted daily gain and calculated daily gain from this experiment, and true daily gain (using data from another experiment with closely related broiler chicken from each of the six strains) will also be discussed in the paper.

  • PDF

Utility of FDG PET-CT Scans on Nodal Staging of Squamous Cell Carcinoma in the Oral Cavity and Oropharynx (구강 및 구인두 편평상피암종의 림프절 전이에 대한 PET-CT 영상의 유용성)

  • Joo, Young-Hoon;Sun, Dong-Il;Park, Jun-Ook;Yoo, Ie-Ryung;Kim, Min-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.1
    • /
    • pp.14-18
    • /
    • 2010
  • Objectives : We evaluated the use of FDG PET/CT for the identification of cervical nodal metastases of SCC of the oral cavity and oropharynx with histological correlation. Material and Methods : We reviewed 46 medical records, from January 2004 to July 2007, of patients who underwent FDG PET/CT and CT/MRI for SCC of the oral cavity and oropharynx before surgery. We recorded the lymph node metastases according to the neck level affected and the system used for the imaging-based nodal classification. Results : The FDG PET/CT had a sensitivity of 75.6% and a specificity of 96.7% ; it had a higher sensitivity than the CT/MRI for identification of cervical metastases on the side of the neck(26/28 vs. 20/28, p=0.031) and at each of the cervical levels(34/45 vs. 26/45, p=0.008). There was a significant difference in the $SUV_{max}$ between the benign and malignant cervical lymph nodes($3.31{\pm}3.23$ vs. $4.22{\pm}2.57$, p=0.028). The receiver-operating-characteristic (ROC) curve analysis for differentiating the benign from the malignant cervical lymph nodes, showed that the area under the curve(AUC) of the FDG PET/CT was 0.775. The cut-off value for the $SUV_{max}$ was 2.23 based on the ROC curve. There was a significant correlation between the $SUV_{max}$ and the size of the cervical lymph nodes(Spearman r=0.353, p=0.048). Conclusion : FDG PET/CT images were more accurate than the CT/MRI images. In addition, the $SUV_{max}$ cut-off values were important for evaluating cervical the cervical nodes in the patients with SCC of the oral cavity and oropharynx.