• Title/Summary/Keyword: Coronoid process fracture

Search Result 10, Processing Time 0.022 seconds

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.

A Case Report of Difficulty in Mouth Opening due to Fracture of Coronoid Process and Zygomatic Arch (관상돌기 및 관골궁의 골절로 기인된 개구장애의 외과적처치에 의한 치험례)

  • Bae, Chang
    • The Journal of the Korean dental association
    • /
    • v.17 no.1 s.116
    • /
    • pp.25-28
    • /
    • 1979
  • An instance of difficulty in mouth opening as around 2mm due to impingement of fractured coronoid process and zygomatic arch in 30-year-old man who had met with a traffic accident was observed and surgical operation was done. After removal of the fractured coronoid process and elevation of the depressed malunited zygomatic arch, the patient could open mouth by now about 30mm.

  • PDF

A CASE REPORT OF THE ARTHROSIS OF THE TEMPOROMANDIBULAR JOINT RESULTED NONTREATED FRACTURES OF THE ZYGOMATIC ARCH AND CORONOID PROCESS (협골궁과 근돌기 골절의 미처치로 초래된 악관절증의 외과적 치험례)

  • Chung, Hoon;Oh, Byung-Sub
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.2
    • /
    • pp.215-220
    • /
    • 1994
  • In the case of the trauma on the maxillofacial region occurred, we think that one of the most important thing is recovery of the function as well as reconstruction of the anatomical form. Especially, it has been that the structure of the surrounded temporomandibular joint has a great possibility to cause mouth opening limitation when a bit of displacement is caused. Therefore, in the case of the trauma on mid-face we think that we treat it after complete evaluate condition of soft and hard tissue surrounding the articular disc as well as fracture site. We report results of our study, since we obtained good results from our study concerning the refixation of the zygomatic arch, high condylectomy, coronoidectomy and myotomy for the patient being suffered from the arthrosis of the temporomandibular joint caused by insufficient fracture treatment of zygomatic arch and coronoid process.

  • PDF

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

Operative Treatment of Terrible Triad in Elbow of Adults (성인 주관절의 요골두와 구상돌기 골절을 동반한 탈구의 수술 적 치료 (성인 주관절에 발생한 위험3증주의 수술적 치료))

  • Kim, Byung-Heum;Park, Jong-Seok;Choi, Ho-Rim;Lee, Sang-Sun;Rah, Soo-Kyun;Lee, Hyun-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.50-59
    • /
    • 2006
  • Purpose: The nonoperative outcome of elbow dislocations with associated radial head and coronoid fractures are often unsatisfactory because of chronic instability and stiffness from proloned immobilization, Therefore we managed these injuries with well programed surgical appproaches. Method: Ten patients with this injury were evaluated retrospectively from May 1998 to June 2004 after a minimum of 12 months. These injuries include elbow dislocation and associated fractures of both the radial head and the coronoid process. All ten patients were treated by one clinic operatively with similar scheduled surgical methods which started on the lateral side and terminated on the medial side of the elbow. Radial head and neck fractures were classified Mason types, as two and three types respectively with six and four cases and six cases were fixated. Coronoid process were fixated with screws anteroposterior directly or anchor suture in all cases, each type was classified one, two and three. where were three type one, four type two, and three type three were according to Regan and Morrey classification. Results: The outcome was three resulting in excellent, four good, two normaland and the remaining case was one poor according to the Mayo Elbow Performance score. At a terminal follow up, the range of motion of the elbow averaged flection contracture, $6^{\circ}(0{\sim}20^{\circ})$ and further flection, $129^{\circ}(115{\sim}140^{\circ})$. Two patients had complications requiring additional care. One, displaced coronoid process which was repaired with capsule and the other patient experienced, palsy of ulnar nerve and contracted elbow joint. Conclusions: Usage of early operation as the minimum injury of medial ligaments complex and the rigid fixation of fractures to prompt motion with our scheduled management for elbow dislocations with associated radial head and coracoid fractures provided excellent results.

Irreducible Elbow Dislocation Associated with Hill-Sachs-like Lesion over the Capitellum

  • Weng, Hung-Kai;Chang, Wei-Lun;Yeh, Ming-Long;Su, Wei-Ren;Hsu, Kai-Lan
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.37-39
    • /
    • 2019
  • Irreducible dislocation of the elbow is an uncommon event. We present the case of a posterolateral elbow dislocation after a fall injury in a 67-year-old woman. A closed reduction performed in the emergency department was unsuccessful since the limited passive range of motion resulted in difficulty to perform longitudinal traction and flexion. Computed tomography images showed that the posterolateral aspect of the capitellum was impacted by the tip of the coronoid process, thus appearing similar to the Hill-Sachs lesion in the humeral head. Subsequent open reduction of the elbow revealed the dislocation to be irreducible since the tip of the coronoid process had wedged into a triangular Hill-Sachs-like lesion in the capitellum. The joint was reduced by providing distal traction on the forearm, and main fragments were disengaged using digital pressure. At the 3-month follow-up, the patient reported no dislocations, and had an acceptable range of motion. Thus, we propose that to avoid iatrogenic injury to the joint or other nearby structures, irreducible dislocations should not be subjected to repeated manipulation.

Plate Fixation for Fractures of the Coronoid Process of the Ulna (금속판을 이용한 구상돌기 골절의 치료)

  • Shin, Dong-Ju;Byun, Young-Soo;Cho, Young-Ho;Park, Ho-Won;Youn, Hee-Min;Han, Jae-Hui
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.177-184
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the results of eight cases of coronoid process fractures that were fixed with a plate. Materials and Methods: Eight coronoid process fractures were treated by plating and these cases were reviewed retrospectively. Six patients were men and two were women. The average age was 41 years (range: 22-79) at the time of injury. According to Regan's classification, there were five type 2 and three type 3. According to O'Driscoll's classification, there were five anteromedial type and three base type. Open reduction and internal fixation with a plate were performed through a medial approach by splitting of the two heads of the flexor carpi ulnaris. The patients were follow-up for a mean of 15.8 months (range: 6-25). We evaluated the clinical outcomes with using the Mayo Elbow Performance Score. Results: The average active motion of the elbow joint was $120^{\circ}$. The average Mayo Elbow Performance Score was 86.9. There were 5 excellent results, 1 good result and 2 fair results. Summary: Plating through a medial approach of the elbow provided stable fixation and satisfactory union for treating displaced coronoid process fractures with the unstable elbow.

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

Trauma severity and mandibular fracture patterns in a regional trauma center

  • Lee, Hyeok;Kim, Kwang Seog;Choi, Jun Ho;Hwang, Jae Ha;Lee, Sam Yong
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.294-300
    • /
    • 2020
  • Background: Mandibular fractures are one of the most common types of facial fractures, the treatment of which can be delayed due to the severity of the trauma resulting in an increase of complications; thus, early evaluation of trauma severity at the time of visit is important. In South Korea, trauma patients are triaged and intensively treated in designated regional trauma centers. This study aimed to analyze the relationship between trauma severity and mandibular fracture patterns. Methods: A medical records review was performed on patients who visited the regional trauma center at our hospital for mandibular fracture between 2009 and 2018. Epidemiologic data and mandibular fracture patterns were analyzed and compared with the conventional facial injury severity scale (FISS). Results: Among 73 patients, 51 were classified as non-severe trauma patients and 22 as severe trauma patients. A higher trauma severity was associated with older age (odds ratio [OR], 1.164; 95% confidence interval [CI], 1.057-1.404) and lower risk was associated with fractures located in the angle (OR, 0.001; 95% CI, 0-0.022), condylar process (OR, 0.001; 95% CI, 0-0.28), and coronoid process (OR, 0.004; 95% CI, 0-0.985). The risk was lower when the injury mechanism was a pedestrian traffic accident (OR, 0.004; 95% CI, 0-0.417) or fall (OR, 0.004; 95% CI, 0-0.663) compared with an in-car traffic accident. Higher FISS (OR, 1.503; 95% CI, 1.155-2.049) was associated with a higher trauma severity. The proposed model was found to predict the trauma severity better than the model using FISS (p< 0.001). Conclusion: Age, location of mandibular fractures, and injury mechanism showed significant relationships with the trauma severity. Epidemiologic data and patterns of mandibular fractures could predict the trauma severity better than FISS.

TREATMENT OF TRISMUS BY CORONOIDECTOMY (오훼돌기 절제술에 의한 개구장애의 치료)

  • Yoon, Hyun-Joong;Lee, Sang-Hwa;Park, Chul-Hong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.376-379
    • /
    • 2001
  • There are many causes of trismus. Aetiology can be roughly divided into muscle spasm, mechanical interference, extracapsular ankylosis, intracapsular ankylosis. Trismus caused by mechanical interference between postero-lateral wall of zygoma-maxillary complex and coronoid process following reduction of fractured facial bone is rare. Especially on maxillary bone fracture, when we faced the trismus following removal of intermaxillary fixation, we got used to solve that problem by physical exercise. We obtained good results by coronoidectomy on patients with limited mouth opening who were referred from department of plastic surgery, St. Marys' hospital, the Catholic university of Korea. We report our experience with literature review.

  • PDF