• Title/Summary/Keyword: Coronary computed tomographic angiography

Search Result 11, Processing Time 0.027 seconds

Vascular anatomy and their variations in Situs inversus totalis using postmortem computed tomographic angiography

  • Dawa Zangpo;Hironobu Nakane;Morio Iino
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.155-159
    • /
    • 2023
  • Studies describing the vascular systems and their variations in Situs inversus totalis (SIT) from a whole-body computed tomographic (CT) angiography perspective are lacking. We report a case of SIT in which postmortem CT angiography (PMCTA) was performed as a part of the forensic death investigation and incidentally detected several vascular variations in it. The PMCTA procedure was performed using the multiphase PMCTA protocol. Almost all major vessels were visualized, indeed in a completely reversed pattern. Contrast mixture flow interruptions were noted in the right coronary arterial branches suggesting possible blockage, upon which autopsy revealed >90% vessel occlusions at several locations. As such the cause of death was due to ischemic heart disease. Anomalous origins of the right internal mammary artery; abnormal left thyrocervical trunk and variations in the drainage of testicular veins were noted. Our findings might be helpful to clinicians and add to the body of literature on SIT.

Application of Quantitative Assessment of Coronary Atherosclerosis by Coronary Computed Tomographic Angiography

  • Su Nam Lee;Andrew Lin;Damini Dey;Daniel S. Berman;Donghee Han
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.518-539
    • /
    • 2024
  • Coronary computed tomography angiography (CCTA) has emerged as a pivotal tool for diagnosing and risk-stratifying patients with suspected coronary artery disease (CAD). Recent advancements in image analysis and artificial intelligence (AI) techniques have enabled the comprehensive quantitative analysis of coronary atherosclerosis. Fully quantitative assessments of coronary stenosis and lumen attenuation have improved the accuracy of assessing stenosis severity and predicting hemodynamically significant lesions. In addition to stenosis evaluation, quantitative plaque analysis plays a crucial role in predicting and monitoring CAD progression. Studies have demonstrated that the quantitative assessment of plaque subtypes based on CT attenuation provides a nuanced understanding of plaque characteristics and their association with cardiovascular events. Quantitative analysis of serial CCTA scans offers a unique perspective on the impact of medical therapies on plaque modification. However, challenges such as time-intensive analyses and variability in software platforms still need to be addressed for broader clinical implementation. The paradigm of CCTA has shifted towards comprehensive quantitative plaque analysis facilitated by technological advancements. As these methods continue to evolve, their integration into routine clinical practice has the potential to enhance risk assessment and guide individualized patient management. This article reviews the evolving landscape of quantitative plaque analysis in CCTA and explores its applications and limitations.

Analysis of Coronary Artery Atheromatous Plaque by Cardiac Computed Tomographic Angiography : Retrospective Analysis of Intravascular Ultrasound Results (심장전산화단층촬영을 이용한 관상동맥 죽상경화반의 분류 : 혈관내초음파 결과를 통한 후향적 분석)

  • Choi, Jae-Sung;Han, Jae-Bok;Choi, Nam-Kil
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.349-356
    • /
    • 2012
  • In the diagnosis of coronary artery atheromatous plaque, Cardiac computed tomography (Cardiac Computed Tomographic Angiography: CCTA) compared with IVUS(Intravascular Ultrasound: IVUS) investigate the diagnostic accuracy, Interested in CCTA atheromatous plaque in computed tomography values (Hounsfield Unit: HU) try to find out. From April 2006 to August 2008 among coronary artery disease(Coronary Artery Disease: CAD) patients with confirmed or suspicious of CAD by CCTA performed atherosclerotic plaques and found 200 patients who underwent IVUS were enrolled. 200 patients who underwent CCTA and IVUS results from the 476 plaque was found, IVUS results of the soft plaque(n; 84), fibrous plaque(n; 63), mixed plaque (n; 97), calcific plaque(n; 232). The results are classified according to the IVUS plaque in HU in the soft plaque : $53.8{\pm}10.5$, fibrous plaque : $108.1{\pm}20.0$, mixed plaque : $371.2{\pm}113.1$, and calcific plaque : $731.0{\pm}160.4$. CCTA had sensitivity of 97% and confidence interval of 95.0-98.3. This study that is the diagnosis of coronary atheromatous plaque for using CCTA, we confirm the high sensitivity and the confidence interval Based on IVUS results CCTA atheromatous plaque with HU in the analysis could be classified to characterize in the treatment of patients with CAD is expected to help.

Coronary Artery Lumen Segmentation Using Location-Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept

  • Cheong-Il Shin;Sang Joon Park;Ji-Hyun Kim;Yeonyee Elizabeth Yoon;Eun-Ah Park;Bon-Kwon Koo;Whal Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.688-698
    • /
    • 2021
  • Objective: To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). Materials and Methods: The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements. Results: Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm3; 95% confidence interval [CI], 4.9-24.3 mm3); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 mm3; 95% CI, -9.1-7.7 mm3). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm2; 95% CI, 0.89-1.25 mm2) but not in the larger lumen area group (mean of difference, -0.07 mm2; 95% CI, -0.22-0.08 mm2). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm2; 95% CI, 0.27-0.65 mm2) than in that of IVUS and SATM (1.53 mm2; 95% CI, 1.27-1.79 mm2). Conclusion: SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.

Determination of Early Graft Patency Using CT Angiography after Coronary Artery Bypass Surgery (관상동맥우회술 후 CT 조영술을 이용한 이식편의 조기 열림의 판정)

  • 이미경;류대웅;최순호;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.570-577
    • /
    • 2004
  • CT angiography is now available to evaluate the early graft patency after coronary bypass surgery. We investigated whether patency or occlusion of the bypass grafts can be visualized by CT angiography and what factors effect the visuality. Material and Method: Fifty patients underwent scanning with a 4-slice computed tomographic scanner (Somatom Volume ZoomTM; Siemens, Germany) before being discharged after coronary artery bypass grafting. To evaluate graft patency and relationship between the quality of graft image and the characteristics of the diseased coronary vessels, 50 internal thoracic artery grafts, 18 radial artery grafts, and 56 vein grafts were included in this study. Result: All vein grafts (24 grafts; 32 anastomoses) to left coronary artery system were well visualized, but 3 grafts (4.7%) of 30 vein grafts (35 anastomoses) to right coronary artery system were not visualized. The latter was also occluded in invasive coronary angiographic study. Thirty-nine (78%) internal thoracic artery grafts were well visualized, 8 (16%) faintly visualized, and 3 (6%) not visualized, but all the internal artery grafts were well patent in invasive coronary angiographic study. Conclusion: Unvisualized vein grafts in CT angiography means occlusion of the grafts, but unvisualized arterial grafts in CT angiography may not mean occlusion of the graft but result from competitive flow between the graft and coronary artery. To confirm patency of the unvisualized arterial grafts, invasive coronary angiography is needed.

Left Carotid-to-Subclavian Artery Bypass Grafting for Recurrent Angina Caused by Coronary-Subclavian Steal Syndrome

  • Kim, Min-Seok;Paeng, Jin Chul;Kim, Ki-Bong;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.84-87
    • /
    • 2013
  • A 60-year-old man visited the outpatient clinic due to one month of recurrent exertional chest pain. Eleven years earlier he had undergone off-pump coronary artery bypass grafting using bilateral internal thoracic artery (ITA) Y-composite grafts based on the left ITA. Preoperative coronary angiography showed patent distal graft anastomoses and visualized the left ITA retrogradely. The arch aortography revealed near-total occlusion of the left subclavian artery at the level of the ostium. The patient underwent left carotid-to-subclavian artery bypass grafting using a 6 mm vascular conduit. Postoperative computed tomographic angiography revealed a patent bypass conduit between the left common carotid artery and left subclavian artery. The patient was discharged on postoperative day 4 with no symptoms or signs of myocardial ischemia.

Change of coronary artery indices according to coronary dominance pattern in early childhood

  • Lee, Yoon Jin;Park, Kyoung Soo;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.6
    • /
    • pp.240-243
    • /
    • 2019
  • Purpose: Coronary arterial lesion assessment in children can be difficult, depending on the coronary dominance pattern. Although it is easier to determine coronary dominance with echocardiography in children than in adults, it is still difficult. This study aimed to examine the coronary dominance pattern according to the objective coronary artery (CA) indices. Methods: The CA diameter, aortic valve annulus, and abdominal aorta of 69 children without any cardiovascular disease were measured with cross-sectional echocardiography at Chungnam National University Hospital. To evaluate the coronary dominance pattern, echocardiography was primarily used; additionally, coronary computed tomographic angiography or coronary angiography (CAG). Coronary dominance was determined according to the status of the CA that gives rise to the posterior descending artery. Results: The mean age was $4.02{\pm}2.78years$, and the mean body surface area (BSA) was $0.70{\pm}0.22m^2$. Right dominance was present in 78% and left in 22% of the subjects. In those with left dominance, the CA to aortic valve annulus diameter ratio was $0.125{\pm}0.021$ in the right coronary artery (RCA) and $0.255{\pm}0.032$ in the left coronary artery (LCA). In those with right dominance, the corresponding ratio was $0.168{\pm}0.028$ in the RCA and $0.216{\pm}0.030$ in the LCA (P<0.05). Significant differences were also found in the diametric ratios of the CA to BSA and abdominal aorta (P<0.05). Conclusion: The CA indices showed significant difference according to the coronary dominance pattern in early childhood. It is possible to indirectly determine the coronary dominance pattern with the CA indices in children using echocardiography. The accuracy of coronary artery lesion diagnosis can be improved by taking coronary dominance into account.

Suspected Intimal Sarcoma in the Abdominal Aorta -A case report- (복부 대동맥에 발생한 혈관 내막 육종 의증 - 1예 보고 -)

  • Choi, Eun-Seok;Kim, Kyung-Hwan;Choi, Jin-Ho;Lee, Jae-Hang;Hwang, Ho-Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.204-207
    • /
    • 2010
  • A 68 year-old man visited our institution due to chest pain. Coronary angiography revealed triple vessel disease. A computed tomographic angiogram performed as a routine preoperative examination demonstrated an intraluminal spider-web-like mass from the infrarenal abdominal aorta to both common iliac arteries. The infrarenal aorta and both common iliac arteries were excised and replaced with concomitant off-pump coronary artery bypass grafts. Histologic examination of the aorta suggested an intimal sarcoma. A postoperative computed tomographic angiogram performed 3 months postoperatively showed no evidence of a residual or a recurred lesion.

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.

Analysis on the Entrance Surface Dose and Contrast Medium Dose at Computed Tomography and Angiography in Cardiovascular Examination (심장혈관검사에서 전산화단층검사와 혈관조영검사의 입사표면선량 및 조영제 사용량에 관한 분석)

  • Seo, Young-Hyun;Han, Jae-Bok;Choi, Nam-Gil;Song, Jong-Nam
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.535-541
    • /
    • 2016
  • This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48~85 years old (mean $65{\pm}10$ years old), and the weight was 37.6~83.3 kg (mean $63{\pm}6kg$). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.