• 제목/요약/키워드: Coronary circulation

검색결과 141건 처리시간 0.021초

Effects of Three Recumbent Postures on Autonomic Nervous System in Patients with Coronary Artery Disease

  • Kim, Wuon-Shik;Hwang, In-Kyoung;Choi, Hyoung-Min
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제3권2호
    • /
    • pp.10-16
    • /
    • 2005
  • Because patients with coronary artery disease (CAD) have depressed vagal modulation and the mortality risk from acute myocardial infarction is lower in patients with higher vagal modulation, methods that can increase vagal modulation are desirable in patients with CAD. We intended to inspect the effect of recumbent posture on vagal modulation. By using angiography, 33 patients with abnormal (CAD group) and 33 patients with normal coronary arteries (control group) were studied. The nonlinear as well as the linear characteristics of heart rate variability (HRV) were analyzed on these patients in three recumbent postures: namely, the supine, right lateral decubitus, and left lateral decubitus postures. The lower the normalized high-frequency power (nHF) in the supine or left lateral decubitus posture, the higher the increase in the nHF when the posture was changed from supine or left lateral decubitus to right lateral decubitus in both groups of patients. Right lateral decubitus posture can lead to the highest vagal modulation and the lowest sympathetic modulation among the three recumbent postures in both normal and patients with CAD. Therefore, the right lateral decubitus posture can be used as an effective physiologic vagal enhancer in patients with CAD.

  • PDF

Functional Angioplasty: Definitions, Historical Overview, and Future Perspectives

  • Hanbit Park;Do-Yoon Kang;Cheol Whan Lee
    • Korean Circulation Journal
    • /
    • 제52권1호
    • /
    • pp.34-46
    • /
    • 2022
  • Percutaneous coronary intervention (PCI) is used to treat obstructive coronary artery disease (CAD). The role of PCI is well defined in acute coronary syndrome, but that for stable CAD remains debatable. Although PCI generally relieves angina in patients with stable CAD, it may not change its prognosis. The extent and severity of CAD are major determinants of prognosis, and complete revascularization (CR) of all ischemia-causing lesions might improve outcomes. Several studies have shown better outcomes with CR than with incomplete revascularization, emphasizing the importance of functional angioplasty. However, different definitions of inducible myocardial ischemia have been used across studies, making their comparison difficult. Various diagnostic tools have been used to estimate the presence, extent, and severity of inducible myocardial ischemia. However, to date, there are no agreed reference standards of inducible myocardial ischemia. The hallmarks of inducible myocardial ischemia such as electrocardiographic changes and regional wall motion abnormalities may be more clinically relevant as the reference standard to define ischemia-causing lesions. In this review, we summarize studies regarding myocardial ischemia, PCI guidance, and possible explanations for similar findings across studies. Also, we provide some insights into the ideal definition of inducible myocardial ischemia and highlight the appropriate PCI strategy.

Stroke after percutaneous transhepatic variceal obliteration of esophageal varix in Caroli syndrome

  • Lee, Yoo Min;Lee, Yoon;Choe, Yon Ho
    • Clinical and Experimental Pediatrics
    • /
    • 제56권11호
    • /
    • pp.500-504
    • /
    • 2013
  • Here we present the case of an 11-year-old female patient diagnosed with Caroli syndrome, who had refractory esophageal varices. The patient had a history of recurrent bleeding from esophageal varices, which was treated with endoscopic variceal ligation thrice over a period of 2 years. However, the bleeding was not controlled. When the patient finally visited the Emergency Department, the hemoglobin level was 4.4 g/dL. Transhepatic intrajugular portosystemic shunt was unsuccessful. Subsequently, the patient underwent percutaneous transhepatic variceal obliteration. Twenty hours after this procedure, the patient complained of aphasia, dizziness, headache, and general weakness. Six hours later, the patient became drowsy and unresponsive to painful stimuli. Lipiodol particles used to embolize the coronary and posterior gastric veins might have passed into the systemic arterial circulation, and they were found to be lodged in the brain, kidney, lung, and stomach. There was no abnormality of the portal vein on portal venography, and blood flow to the azygos vein through the paravertebral and hemiazygos systems was found to drain to the systemic circulation on coronary venography. Contrast echocardiography showed no pulmonary arteriovenous fistula. Symptoms improved with conservative management, and the esophageal varices were found to have improved on esophagogastroduodenoscopy.

Deleterious Effects of Hyperoxemic Extracorporeal Circulation during Cardiovascular Surgery

  • Park, Seok-Cheol
    • Biomedical Science Letters
    • /
    • 제7권1호
    • /
    • pp.7-15
    • /
    • 2001
  • Although extracorporeal circulation (ECC) has been routinely used for cardiovascular surgery, hyperoxemia during ECC may produce oxygen toxicity and cellular injury. This study was performed to investigate the clinical influences of hyperoxemic ECC during cardiovascular operation. 40 adult patients scheduled for elective cardiovascular surgery were classified into normoxemic (arterial oxygen tension: 115 mmHg, n=20) and hyperoxemic (arterial oxygen tension: 380 mmHg, n=20) ECC. At preoperative and postoperative period, total leukocyte and neutrophil counts, platelet counts, iron, glucose, aspartate aminotransferase (AST), alanine aminotransferase (ALT), blood urea nitrogen (BUN), and creatinine in peripheral arterial blood, malondialdehyde (MDA) and troponin-T concentration (TnT) in coronary sinus blood, pulmonary vascular resistance (PVR), and postoperative blood loss volume (BLS) were measured and compared between groups. Hyperoxemic group had postoperatively higher total leukocyte and neutrophil counts, MDA, TnT, PVR total BLS, iron, glucose, AST, ALT, BUN, and creatinine than normoxemic group (p<0.05).0 conclusion, hyperoxemic ECC results in greater inflammatory response and oxidative damaging effects on the heart lung, liver and kidney, probably being adverse to postoperative patient recovery. For reducing these deleterious effects and improving postoperative outcomes, management lowering oxygen tension during ECC is recommended.

  • PDF

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

Coronary Intravascular Lithotripsy Versus Rotational Atherectomy in an Asian Population: Clinical Outcomes in Real-World Patients

  • Jie Jun Wong;Sridharan Umapathy;Yann Shan Keh;Yee How Lau;Jonathan Yap;Muhammad Idu;Chee Yang Chin;Jiang Ming Fam;Boon Wah Liew;Chee Tang Chin;Philip En Hou Wong;Tian Hai Koh;Khung Keong Yeo
    • Korean Circulation Journal
    • /
    • 제52권4호
    • /
    • pp.288-300
    • /
    • 2022
  • Background and Objectives: We compared real-world clinical outcomes of patients receiving intravascular lithotripsy (IVL) versus rotational atherectomy (RA) for heavily calcified coronary lesions. Methods: Fifty-three patients who received IVL from January 2017 to July 2020 were retrospectively compared to 271 patients who received RA from January 2017 to December 2018. Primary endpoints were in-hospital and 30-day major adverse cardiovascular events (MACE). Results: IVL patients had a higher prevalence of acute coronary syndrome (56.6% vs 24.4, p<0.001), multivessel disease (96.2% vs 73.3%, p<0.001) and emergency procedures (17.0% vs 2.2%, p<0.001) compared to RA. In-hospital MACE (11.3% vs 5.9%, p=0.152), MI (7.5% vs 3.3%, p=0.152), and mortality (5.7% vs 3.0%, p=0.319) were not statistically significant. 30-day MACE was higher in the IVL cohort vs RA (17.0% vs 7.4%, p=0.035). Propensity score adjusted regression using IVL was also performed on in-hospital MACE (odds ratio [OR], 1.677; 95% confidence interval [CI], 0.588-4.779) and 30-day MACE (OR, 1.910; 95% CI, 0.774-4.718). Conclusions: These findings represent our initial IVL experience in a high-risk, real-world cohort. Although the event rate in the IVL arm was numerically higher compared to RA, the small numbers and retrospective nature of this study preclude definitive conclusions. These clinical outcomes are likely to improve with greater experience and better case selection, allowing IVL to effectively treat complex calcified coronary lesions.

Osstem Cardiotec Centum Stent Versus Xience Alpine Stent for De Novo Coronary Artery Lesion: A Multicenter, Randomized, Parallel-Designed, Single Blind Test

  • Chang-Hwan Yoon;Jihong Jang;Seung Ho Hur;Jun-Hee Lee;Seung Hwan Han;Soon-Jun Hong;Kiyuk Chang;In-Ho Chae
    • Korean Circulation Journal
    • /
    • 제52권5호
    • /
    • pp.354-364
    • /
    • 2022
  • Background and objectives: To compare the safety and efficacy of a new everolimus-eluting stent with an abluminal-coated biodegradable polymer (Osstem Cardiotec Centum) with those of the Xience Alpine stent (Xience). Methods: This randomized, prospective, multicenter, parallel-designed, single-blind trial was conducted among patients with myocardial ischemia undergoing percutaneous coronary intervention (PCI) from 21st September 2018 until 3rd July 2020. The primary efficacy endpoint was in-segment late lumen loss (LLL) at 270 days after the procedure and the primary safety endpoints were major adverse cardiac events (MACE), composite of cardiac death, myocardial infarction, and target lesion revascularization. Results: We enrolled 121 patients and analyzed 113 patients who finished 270 days of follow-up for the primary efficacy endpoint. The mean age of the participants was 66.8 years. As for the primary efficacy endpoint, LLL of the Osstem Cardiotec Centum group was 0.09±0.13 mm and that of the Xience group was 0.12±0.14 mm (upper limit of 1-sided 95% confidence interval, 0.02; p for non-inferiority, 0.0084). This result demonstrates the non-inferiority of the Osstem Cardiotec Centum. As for the primary safety endpoint, MACE occurred in one patient (1.59% of the Xience group). Meanwhile, no MACE occurred in the Osstem Cardiotec Centum group. Conclusions: The Osstem Cardiotec Centum is non-inferior to the Xience Alpine® stent and is confirmed to be safe. It could be safely and effectively applied to patients with coronary artery disease undergoing PCI.

Congenital Aortic Valvular Stenosis: report of a case (선천성 대동맥판막 협착증 치험 1례)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제12권4호
    • /
    • pp.350-354
    • /
    • 1979
  • The incidence of congenital aortic valvular stenosis has been known rare, and approximately 3-6% of congenital heart diseases. Recently, we experienced 1 case of congenital aortic valvular stenosis, and which was corrected surgically under extracorporeal circulation successfully. A 11 years old male pt. was admitted to N.M.C. because of dyspnea, dizziness, chest pain and episode of syncope. An auscultation, harsh systolic murmur [Gr. IV/VI] was noted at aortic area and also palpable strong thrill. ECG showed LVH c strain pattern and suspicious LVH finding in simple chest P-A film. In Lt. cardiac catheterization, abrupt pressure change [110mmHg] between LV & Aorta was noted across the aortic valve. And aortic insufficiency was absent, well visualized both coronary arteries and suspicious bicuspid aortic valve in aortography. Valve form was bicuspid, large one was noncoronary cusp and another cusp was Rt. & Lt. coronary cusp which was interpositioned rudimentary commissure. Central aortic orifice was about 5ram in diameter. Valvulotomy was done along the fusioned commissure between noncoronary cusp and Rt. & Lt.coronary cusp, and then short incision was added between Rt. coronary cusp & Lt. coronary cusp. Immediate postoperative course smooth but unknown cardiac arrest was noted in POD second day. Complete recovery was done without sequelae by resuscitation. After operation, clinical symptoms were subsided but systolic murmur [Gr. II/VI] was audible at aortic area, diastolic murmur was absent. ECG showed still remained LVH but much decreased R wave voltage in Lt. precordial leads. Simple chest P-A showed no interval changes compared to preop film. Control Lt. heart catheterization revealed still remained pressure gradient [40ramrig] between LV & Aorta. But much decreased pressure gradient compared to preop pressure gradient [110mmHg].

  • PDF

Diagnostic Performance of On-Site Automatic Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve

  • Doyeon Hwang;Sang-Hyeon Park;Chang-Wook Nam;Joon-Hyung Doh;Hyun Kuk Kim;Yongcheol Kim;Eun Ju Chun;Bon-Kwon Koo
    • Korean Circulation Journal
    • /
    • 제54권7호
    • /
    • pp.382-394
    • /
    • 2024
  • Background and Objectives: Fractional flow reserve (FFR) is an invasive standard method to identify ischemia-causing coronary artery disease (CAD). With the advancement of technology, FFR can be noninvasively computed from coronary computed tomography angiography (CCTA). Recently, a novel simpler method has been developed to calculate onsite CCTA-derived FFR (CT-FFR) with a commercially available workstation. Methods: A total of 319 CAD patients who underwent CCTA, invasive coronary angiography, and FFR measurement were included. The primary outcome was the accuracy of CT-FFR for defining myocardial ischemia evaluated with an invasive FFR as a reference. The presence of ischemia was defined as FFR ≤0.80. Anatomical obstructive stenosis was defined as diameter stenosis on CCTA ≥50%, and the diagnostic performance of CT-FFR and CCTA stenosis for ischemia was compared. Results: Among participants (mean age 64.7±9.4 years, male 77.7%), mean FFR was 0.82±0.10, and 126 (39.5%) patients had an invasive FFR value of ≤0.80. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR were 80.6% (95% confidence interval [CI], 80.5-80.7%), 88.1% (95% CI, 82.4-93.7%), 75.6% (95% CI, 69.6-81.7%), 70.3% (95% CI, 63.1-77.4%), and 90.7% (95% CI, 86.2-95.2%), respectively. CT-FFR had higher diagnostic accuracy (80.6% vs. 59.1%, p<0.001) and discriminant ability (area under the curve from receiver operating characteristic curve 0.86 vs. 0.64, p<0.001), compared with anatomical obstructive stenosis on CCTA. Conclusions: This novel CT-FFR obtained from an on-site workstation demonstrated clinically acceptable diagnostic performance and provided better diagnostic accuracy and discriminant ability for identifying hemodynamically significant lesions than CCTA alone.

Blood Conservation in Coronary Artery Bypass Surgery - in 24 consecutive patients - (관상동맥 우회로술 환자에서 혈액 보존법)

  • 최종범
    • Journal of Chest Surgery
    • /
    • 제25권10호
    • /
    • pp.1048-1054
    • /
    • 1992
  • With use of a simple, inexpensive and nonpharmacological program for blood conservation, 24 consecutive patients underwent elective or urgent coronary artery bypass grafting without need of homologous red cell transfusions and /or fresh frozen plasma transfusions in 16 patients[66.7%]. Left internal mammary artery graftings were done in 18 patients[75%], with supplemental saphenous vein grafts in all. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of ext-racorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the oxygenator, autotransfusion of the shed mediastinal blood was continued hourly by the next early;norning. The mean postoperative mediastinal blood loss was 364$\pm$234ml, whereas 553$\pm$383ml was autotransfused. 4 patients [16.7%] received homologous blood and an additional 4 patients[16.7%] fresh frozen plasma. Thus, in total, 16 patients[66.7%] were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 10.3$\pm$1.6g /dl. Postoperative complications were few and there was no hospital death.

  • PDF