• Title/Summary/Keyword: Corona ring

Search Result 16, Processing Time 0.03 seconds

The Characteristics of the Ionic Wind Generation with Corona Electrodes Installed in Form of the Ring (환형 배치된 코로나 전극에 의한 이온풍 발생 특성)

  • Kim, Jin-Gyu;Jung, Jae-Seung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.54-59
    • /
    • 2014
  • The electric power can be converted into the mechanical power by a corona discharge system. This way has not stronger force than a electric motor. But it has been applied in various industrial fields because of many advantages, no moving parts, smaller noise, simpler structure, minimizing et al. In this paper, corona discharge system with multiple corona electrode installed in form of the ring, has been studied by focusing on the electrical and mechanical characteristics. Intensity of the corona discharge depends on applied electric field, and electric field is related to the applied voltage, discharge gap spacing(s), distance between each corona electrodes(d). As a result, in the case d/s=0.9, most intensive discharge occurred in this experiments. In the region of d/s<0.9, ionic wind velocity has saturation value in spite of decreasing corona current, because each ion velocities increase by the increasing electric field.

End-fitting Design and Performance Evaluation of Polymer Insulator (폴리머 애자의 End-fitting 설계 및 성능 평가기술)

  • Cho, H.G.;Lee, U.Y.;Han, S.W.;Han, D.H.;Ji, W.Y.;Yeo, H.G.;Kang, D.W.;Chun, J.U.;Lee, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

The study on characteristics of corona ignitor for surface treatment of insulator (절연재료의 표면개질을 위한 코로나 발생기의 특성에 관한 연구)

  • ;;;;Y.Tabata;J.S Chang
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.504-508
    • /
    • 1995
  • The purpose of this research is to study on characteristics of corona ignitor which was designed for ignition of plasma, used at hard coating, surface treatment and thin film preparation, at high pressure. Corona ignitor composed of hollow type inner electrode and ring type external electrode. Though corona voltage increased with increasing distance between electrodes, corona discharge can be controlled stably. The gas flow in hollow type inner electrode and the construction between electrodes affect a length of corona flame and corona phenomenon. It is possible to ignite the . plasma, usually generated at low pressure(10 Torr), at high pressure(100 Torr) by corona ignitor.

  • PDF

Massive Hemorrhage Caused by a Non-Displaced Pubic Ramus Fracture from Low-Energy Trauma (저에너지 외상에 의한 비전위 치골지 골절에서 발생한 대량출혈)

  • Na, Hwa-Yeop;Shin, Keun-Young;Choe, Saehun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.557-561
    • /
    • 2019
  • Most low-energy pelvic ring fractures in elderly patients are treated conservatively so that an initial evaluation for complications such as vascular injury is usually overlooked. An 81-year-old female, who was taking regular aspirin, visited the emergency room and was diagnosed with a simple non-displaced pubic ramus fracture from a low-energy fall from standing, which was complicated by massive hemorrhage from the overlooked injury of the corona mortis. Elderly patients with pelvic ring fractures can have a delayed presentation of vascular injuries, regardless of the degree of displacement of the fractures, which highlights the need for a careful physical examination and close monitoring.

Characteristics of Ion Wind Generation According to Application of Acceleration Electrodes (가속전극의 적용에 따른 이온풍 발생 특성)

  • Kim, Chol-Gyu;Jang, Kyeong-Min;Kim, Jin-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.5
    • /
    • pp.656-661
    • /
    • 2019
  • Currently, the devices to generate ion winds in air are mainly composed of corona electrodes and induction(ground) electrodes, of which the corona electrodes mainly use needles or wires as electrodes and the induction electrodes use plate electrodes of ring or mesh type. Ion winds can be effectively generated through a diverse combination of corona electrodes and induction electrodes mentioned above. However, only changing the form and structure of corona electrodes and induction electrodes has a limit in raising the speed of ion winds. This paper conducted a study on the characteristics of ion wind generation by additionally installing acceleration electrodes in addition to corona electrodes and induction electrodes to increase the speed of ion winds.

Surface Characterization of Silicone Rubber for Outdoor Insulation by Measurement of Surface Voltage Decay

  • Youn, Bok-Hee;Huh, Chang-Su;Cho, Han-Gu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.214-219
    • /
    • 2002
  • The influence of ultraviolet (UV) irradiation and corona on the surface degradation of high temperature vulcanized (HTV) silicone rubber used for outdoor insulation through measuring surface voltage decay after corona charging, surface resistivity, contact angle and X-ray photoelectron spectroscopy (XPS) analysis was studied. The surface resistivity calculated by the surface voltage decay was compared with a value directly obtained from the three electrode method having the guard ring electrode. A good agreement between the two methods for surface resistivity was obtained. UV treated specimens showed the slower decrease of surface voltage decay, while the corona exposed specimens showed a dramatically faster decrease. Although both artificial treatments cause the same oxidative products, which was confirmed with XPS, we could distinguish the difference between the reactions of the two treatments by monitoring the surface voltage decay on corona-charged specimen. In addition, we could derive the specific surface states of the silicone rubber treated by accelerated artificial aging factors and the degradation process.

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Rearrangement of Benzyl-type Radical in Corona Discharge of 2,6-Dichlorotoluene

  • Yoon, Young-Wook;Lee, Seung-Woon;Lee, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2479-2482
    • /
    • 2010
  • Using a pinhole-type glass nozzle equipped for a corona-excited supersonic expansion (CESE), precursor 2,6-dichlorotoluene seeded in a large amount of inert carrier gas helium was discharged to produce jet-cooled but electronically excited benzyl-type radicals. The visible vibronic emission spectrum was recorded with a long-path monochromator to observe vibronic bands in the $D_1{\rightarrow}D_0$ electronic transition of benzyl-type radicals. The spectral analysis revealed the generation of not only the 2,6-dichlorobenzyl radical as a typical product, but also the o-chlorobenzyl radical as an unexpected species, which indicates the possible molecular rearrangement in eliminating a chlorine atom from the benzene ring. A possible mechanism is proposed for the formation of the o-chlorobenzyl radical from the precurs or in the gas phase.

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF